Output Voltage | (2) 0 to 24VDC, (1) 5VDC fixed |
Output Current | (2) 0 to 500mA, (1) 4A |
Constant Voltage Operation | |
Line Regulation | < 0.01% + 3mV main |
| < 5mV for line fixed supply |
Load Regulation | < 0.01% + 3mV main |
| < 10mV fixed |
Recovery time | 100uS |
Ripple & Noise (5 Hz to 1 MHz) | <1 mVrms (≤5 mV rms for fixed output) |
Temperature Coefficient | < 300 ppm°C |
Constant Current Operation | |
Adjustable Current Range | 5% to 100% |
Line Regulation | < 0.2% + 6mA |
Load Regulation | <0.2% + 3uA |
Current Ripple | < 3mA rms |
Metering | |
Display | 2 digital LED |
Voltage range | 00.0 - 99.9 (main output) |
Voltage Accuracy | +(0.5% rdg + 2 digits) |
Ampmeter Range | 000 - .999 (main output) |
Ampmeter Accuracy | +(0.5% rdg + 2 digits) |
Ampmeter Range | |
Overload Protection | Short circuit, over voltage, and reverse polarity protection |
Power Requirements | 108-132VAC 60Hz, (120/220, +10%, 50/60Hz versions available) |
Power Consumption | 165W |
Operating Temperature | 0° to 40°C < 85% R.H. |
Storage Temperature | 15° to 70°C < 85% R.H. |
Dimension | (H x W x D) 5.5 x 11.75 x 10.975" (140 x 298 x 264 mm) |
Weight | 10.5 lbs. (4.8 kg) |