B+K Precision's model 2121 is a dual trace oscilloscope with a built in 50MHz Frequency Counter that offers high performance at a low price. Most competitor's entry level oscilloscopes have a 20 MHz bandwidth, while B+K Precision's models 2121 has a bandwidth of 30 MHz. This oscilloscope is built by and backed by B+K Precision, a company that has been selling reliable, durable, value priced test instruments for over 50 years
List Price: $599.00
Add to Cart

Specifications
VERTICAL AMPLIFIERS (CH 1 and CH 2)
Sensitivity5 mV/div to 5 V/div, 1 mV/div to 1 V/div at X5
Attenuator10 steps in 1-2-5 sequence. Vernier control provides full adjustment between steps.
Accuracy+-3%, +-5% at X5
Input Resistance1 M +- 2%
Input Capacitance25 pF +- 10pF
Frequency Response5 mV to 5 V/div: DC to 30 MHz (-3 dB). X5: DC to 10 MHz (-3 dB)
Rise Time12 ns (Overshoot <= 5%)
Operating ModesCH 1: CH 1, single trace
CH 2CH 2, single trace
ALTdual trace, alternating
CHOPdual trace, chopped
ADDalgebraic sum of CH 1 + CH 2
Polarity ReversalCH 2 only
Maximum Input Voltage400 V (DC + AC peak)
SWEEP SYSTEM
Sweep Speed0.1 us/div to 2s/div in 1-2-5 sequence, 23 steps. Vernier control provides fully adjustable sweep time between steps.
Accuracy+-3%
Sweep Magnification10x
TRIGGERING
Triggering ModesAUTO (free run) or NORM, TV-V, TV-H
Trigger SourceCH 1, CH 2, ALT, EXT, LINE
Maximum External Trigger Voltage300 V (DC + AC peak)
Trigger CouplingAC 30 Hz to 30 MHz
TV HUsed for triggering from horizontal sync pulses
TV VUsed for triggering from vertical sync pulses
TRIGGER SENSITIVITY
CouplingBandwidthIntExt
Auto100 Hz - 30 MHz1.5 div.100 mV
NormDC to 30 MHz1.5 div100 mV
TV V20 Hz-1 kHz5 div100 mV
TV H1 kHz-100 kHz.5 div100 mV
HORIZONTAL AMPLIFIER (Input through channel 2 input)
X-Y ModeSwitch selectable using X-Y switch. CH 1: X axis
CH 2Y axis
SensitivitySame as vertical channel 1
Input ImpedanceSame as vertical channel 1
Frequency ResponseDC to 1 MHz typical (-3 dB)
X-Y Phase DifferenceApproximately 3'' at 50 kHz
Maximum Input VoltageSame as vertical channel 1
CRT
TypeRectangular with internal graticule
Display Area8x10 div (1 div = 1 cm)
Accelerating Voltage2 kV
PhosphorP31
Trace RotationElectrical, front panel adjustable
Display ResolutionAuto select from 0.001Hz to 1KHz depending on the frequency
Max Counter Range0.1Hz to 50MHz
Max External Voltage300V dc + ac peak
Accuracy+0.01% + 1 digit or 1/99999 + 1 digit
Time Base18,432MHz + 10ppm (230 C +/- 50 C)
SensitivityElectrical, front panel adjustable
SensitivityNote:
  1. The counter n=must be set at "DC COUPLING" operation then the input signal is less than 10Hz
  2. The counter is operated by the "Trigger Source" CH1, CH2, or EXT.
ModeRangeSensitivity
INT2Hz ~ 40MHz>= 1 Div
1Hz ~ 45MHz>= 2 Div
0.2Hz ~ 50MHz>= 3 Div
EXT10Hz ~ 50MHz>= 200m Vrms
1Hz ~ 50MHz>= 400m Vrms
 
Other Specifications
Calibrating Voltage1 kHz (+-10%) Positive Square Wave, 2 V p-p (+-3%)
ENVIRONMENT
Within Specified Accuracy50 0 to 95 0 F (10 0 to 35 0 C), <= 85% RH
Full Operation32 0 to 104 0 F (0 0 to 40 0 C), <=85% RH
Storage-4 0 to 158 0 F (-20 0 to +70 0 C)
Power Requirements100/120/220/240 VAC +- 10%, 50/60 Hz, approximately 40 W.
Dimensions (WxHxD)7x14.5x17.25'' (180 x 370 x 440 mm)
WeightApproximately 17.2 lbs. (7.8 kg)
Two Year Warranty
Accessories
SUPPLIED: Instruction Manual, Two PR-33A x1/x10 Probes or equivalent, AC Power Cord, Spare Fuse
OPTIONAL: PR-32A Demodulator Probe, PR-37A x1/x10/REE Probe, PR-100A x 100 Probe, PR-55 High Voltage x1000 Probe, LC-210A Carrying Case


Categories
Power Supplies
Generators
Spectrum Analyzers
Oscilloscopes
Component Testers
Electronic DC Load
Multimeters
Clamp Meters
Counters
Environmental Testers
Electrical Testers
Cables
Telephone Testers
Test Accessories
Device Programmers
Battery Analyzers
Video Testers
Accessories
Static Control Products