B+K Precision's model 2125A is a dual trace oscilloscope with a delayed sweep that offers high performance at a low price. Most competitor's entry level oscilloscopes have a 20 MHz bandwidth, while B+K Precision's models 2125A has a bandwidth of 30 MHz. This oscilloscope is built by and backed by B+K Precision, a company that has been selling reliable, durable, value priced test instruments for over 50 years
List Price: $646.00
Add to Cart2125A

Specifications
VERTICAL AMPLIFIERS (CH 1 and CH 2)
Sensitivity5 mV/div to 5 V/div, 1 mV/div to 1 V/div at x5
Attenuator10 steps in 1-2-5 sequence. Vernier control provides full adjustment between steps
Accuracy+-3%, +-5% at x5
Input Resistance1 M + 2%
Input Capacitance25 pF +- 10pF
Frequency Response5 mV to 5V/div: DC to 30 MHz (-3 dB)
X5: DC to 10 MHz (-3 dB)
Rise Time12 ns (Overshoot <= 5%)
Operating ModesCH 1: CH 1, single trace
CH 2CH 2, single trace
ALTdual trace, alternating
CHOPdual trace, chopped
ADDalgebraic sum of CH 1 + CH 2
Polarity ReversalCH 2 only
Max. Input Voltage400 V (DC to AC peak)
SWEEP SYSTEM
Operating ModesMain, mix (both main sweep and delay sweep displayed), or Delay (only delay sweep displayed), X-Y
Main Sweep SpeeD0.1 us/div to 2.0 s/div in 1-2-5 sequence, 23 steps Vernier control provides fully adjustable sweep time between steps
Accuracy+-3%
Sweep Magnification10X, +-5%
Delayed Sweep Speed0.1 ms/div to 0.1 s/div in 1-2-5 sequence, 23 steps
HoldoffContinuously variable for Main sweep up to 10 times normal
Delay Time PositionContinuously variable to control percentage of display that is devoted to main and delay sweep
TRIGGERING
Triggering ModesAUTO (free run) or NORM, TV-V, TV-H
Trigger SourceCH 1, CH 2, ALT, EXT, LINE
Maximum External Trigger Voltage300 V (DC + AC peak)
Trigger CouplingAC 30 Hz to 30 MHz
 TV H Used for triggering from horizontal syns pulses
 TV H Used for triggering from vertical syns pulses
TRIGGER SENSITIVITY
CouplingBandwidthIntExt
Auto100Hz - 40MHz1.5 div.>=0.1Vp-p
Norm100 Hz - 40 MHz1.5 div.>=0.1Vp-p
TV-VDC - 1kHz0.5 div>= 0.05Vp-p
TV-H1 kHz - 100 kHz0.5 div>= 0.05 Vp-p
HORIZONTAL AMPLIFIER (Input through channel 1 input)
X-Y ModeSwitch selectable using X-Y switch, CH 1: X axis CH 2: Y axis
SensitivitySame as vertical channel 2
AccuracyY-Axis: +-3%. X-Axis: +-6%
Input Impedancesame as vertical channel 2
Frequency ResponseDC to 1 MHz typical (-3 dB), to 6 div horizontal deflection
X-Y Phase Difference3 0 or less at 50 kHz
Max. Input VoltageSame as vertical channel 2
CRT
TypeRectangular with internal graticule
Display Area8 x 10 div (1 div = 1 cm)
Accelerating Voltage2 kV
PhosphorP31
Trace RotationElectrical, front panel adjustable
COMPONENT TESTER
Components TestedResistors, Capacitors, Inductors, and Semiconductors
Test Voltage6V rms maximum (open)
Test Current11 mA maximum (shorted)
Test FrequencyLine Frequency (60Hz in USA)
Calibrating Voltage1 kHz (+-10%) Positive Square Wave, 0.2 V p-p (+-2%)
Other Specifications
Within Specified Accuracy50 0 to 95 0 F (10 0 to 35 0 C), <= 85% RH
Full Operation32 0 to 104 0 F (0 0 to 40 0 C), <= 85% RH
Storage-4 0 to 158 0 F (-20 0 to +70 0 C)
Power RequirementsApproximately 40 W
All other operating specifications are the same as model 2120A
Dimensions (WxHxD)7x14.5x14.25'' (180x370x440 mm)
WeightApproximately 17.2 lbs. (7.8 kg)
Three Year Warranty
Accessories
SUPPLIED: Instruction Manual, Two PR-33A x1/x10 Probes or equivalent, AC Power Cord, Spare Fuse
OPTIONAL: PR-32A Demodulator Probe, PR-37A x1/x10/REE Probe, LC-210A Carrying Case


Categories
Power Supplies
Generators
Spectrum Analyzers
Oscilloscopes
Component Testers
Electronic DC Load
Multimeters
Clamp Meters
Counters
Environmental Testers
Electrical Testers
Cables
Telephone Testers
Test Accessories
Device Programmers
Battery Analyzers
Video Testers
Accessories
Static Control Products