Site Search:
Products Check Stock Suppliers Contact Us Home

BK Precision 2652 - 3.3 GHz Handheld Spectrum Analyzer with Tracking Generator
2652 - 3.3 GHz Handheld Spectrum Analyzer with Tracking Generator
BK Precision 2652 - 3.3 GHz Handheld Spectrum Analyzer with Tracking Generator
B+K Precision's 2652 handheld spectrum analyzer is small and exceptionally light weight, yet delivers performance and features comparable to a full size bench spectrum analyzer. The 2652 is a 2650 with a tracking generator added and can be used to rapidly determine transmission characteristics of two-port RF devices. With its ease of use, great performance and broad functionality, the 2652 is an ideal tool for engineers and technicians who perform field measurements in the 50kHz to 3.3GHz range.

Applications:

  • Frequency response measurements of passive components such as RF cables, filters, and attenuators
  • Installation, maintenance, and trouble shooting of wireless communication systems such as W-CDMA/CDMA, GSM, WLAN and Bluetooth
  • Detection of signal interference and undesired emissions
  • TV and broadcasting
  • Antenna alignment
  • EMI compliance (E & H field measurements with optional accessories)
  • .

    List Price: $8,950.00
    Add to Cart

    Specifications

    Frequency section

    Frequency range

    50kHz to 3.3GHz

    Center frequency

     

    Resolution

    100kHz
    Settable via rotary encoder, numeric or function key

    Accuracy

    within ±(30 + 20T)kHz ± 1dot
       @frequency span: 200kHz to 10MHz, RBW: 30kHz,
           23 ± 5°C

    within ±(100 + 700T)kHz ± 1dot
       @frequency span: 20MHz to 3.3GHz, RBW: 100kHz,
           23 ± 5°C

    T: Sweep time(s)

    RBW frequency error

    within ±6% of RBW @RBW: 3kHz, 30kHz
    within ±30% of RBW @RBW: 100kHz to 3MHz

    Frequency span

     

    Range

    0Hz (zero span),
    200kHz to 2GHz (1-2-5 step) and 3.3GHz

    Accuracy

    within ±3% ± 20TkHz ± 1dot
       @frequency span: 200kHz to 10MHz, 23 ± 5°C

    within ±3% ± 200TkHz ± 1dot
       @frequency span: 20MHz to 3.3GHz, 23 ± 5°C

    T: Sweep time(s)

    Display resolution

    (horizontal)

    Frequency span/250
    The unit displays 251 horizontal dots but stores 1001 trace data points internally which can be captured via RS232 interface

    Resolution bandwidth (-3dB bandwidth)

     

    Range

    3kHz to 3MHz (1-3 step) and AUTO

    Accuracy

    within ±20%

    Shape Factor

    1:12 (typical, 3dB:60dB)

    Video bandwidth

    100Hz to 1MHz (1-3 step), AUTO

    SSB phase noise

    -90dBc/Hz (typical) @100kHz offset, RBW: 3kHz, VBW: 100Hz, Sweep time: 0.3s

    Spurious response

    < -60dBc

    Harmonics

    < -40dBc @100MHz to 3.3GHz

    Amplitude section

    Reference level

     

    Range

    +10 to -60dBm (1dB step)

    Accuracy

    within ±0.8dB ± 1dot
    @center frequency: 100MHz, RBW: 3MHz, VBW: 1MHz, ATT: 0dB, 23 ± 5°C

    Unit

    dBm, dBV, dBmV, dBµV, dBµV/m, dBµA/m
    (dBµV/m and dBµA/m are available for certain measurement functions)

    Average noise level

    -110dBm (typical)
    @center frequency: 100MHz, RBW: 3kHz, VBW: 100Hz

    Frequency response

    Within ±2.0dB ± 1dot @50kHz to 100MHz
    Within ±1.0dB ± 1dot @100MHz to 3.3GHz

    Input impedance

    50Ω

    Input VSWR

    < 2.0

    Input attenuator

     

    Operating range

    0 to 25dB (1dB step), coupled with reference level

    Switching error

    within ±0.6dB @100MHz

    RBW switching error

    within ±0.6dB

    Display resolution

    200 dots

    Display scale

     

    Scale

    10dB/div, 2dB/div

    Accuracy

    within ±0.8dB/10dB ± 1dot
    within ±0.2dB/2dB ± 1dot
    within ±1.6dB/70dB ± 1dot

    Input damage level

    +23dBm (CW average power), 25VDC

    Sweep section

    Sweep time

     

    Range

    10ms to 30s and AUTO (1-3 step) @ 0 to 2GHz span
    30ms to 30s and AUTO (1-3 step) @full span

    Accuracy

    within ±0.1% ± 1dot @ 0 to 2GHz span
    within ±1.5% ± 1dot @ full span

    Trigger mode

    AUTO (frequency span: zero span)

    Detection mode

    Positive peak, Negative peak, Sample

    Measurement and Calculation Functions

    Markers

    NORM: displays frequency (7 digits max) and level (4 digits max) at marker point.
    DELTA: displays ∆f (Frequency) and ∆dBx (level)

    Peak search

    NORM: searches a peak point within full range.  This mode also supports NEXT peak (10max).
    ZONE: searches a peak point within a zone defined by center and width.

    Calculations

    NORM, MAX HOLD, MIN HOLD, AVERAGE, OVER WRITE
    MAX/MIN HOLD: 2 to 1024 times

    AVERAGE: 2 to 256

    Measurements

    Measure Channel power, Adjacent channel leakage power, Occupied frequency bandwidth, Electric field strength (requires antenna), Magnetic field strength (requires magnetic field probe)

    AUTO tuning

    Automatically scans the full bandwidth, detects the maximum level spectrum and centers it on screen.  Automatically adjusts reference level, RBW, VBW and sweep time to optimum levels.

    Tracking Generator

       Frequency range

    5MHz to 3.3GHz

       Output Level

    -10dBm ± 1dB @1GHz (fixed)

       Output flatness

    ±1.5dB

       Output impedance

    50Ω

       VSWR

    < 2.0

       Output connector

    SMA (J)

    General

    Input connector

    SMA (J)

    Save/Load

     

    Save

    Saves 100 traces and 100 setups

    Load

    Loads 1 trace and 1 setup

    Communications

     

    Interface

    RS-232C

    Baud rate

    2,400 to 38,400bps

    Hard copy (Allows direct hard copy with optional printer.)

    Display

     

    Display

    LCD

    Backlight

    CFL backlight

    Resolution

    320 (H) × 240 (V) dots

    Power source

     

    Battery

    Ni-MH battery

       Operating
       Time

    Approx. 110 min. with the backlight turned off
    (battery fully charged)

    External DC source

    DC jack, +4.75 to +5.25VDC/4A

    Immunity of radiated interference
    Level display at 10V/m

    Less than -35dBc (reference level: 10dBm)

    Immunity to cabled interference
    Level display at transient interference of 4.0kV

    Less than -30dBc (reference level: 10dBm)

    Environmental and size

    Operating temperature

    0 to 50°C (Guaranteed at 23 ± 10°C, without soft carrying case)

    Operating humidity

    less than 40°C/80%RH
    (Guaranteed at less than 33°C/70%RH, without soft carrying case)

    Storage temperature

    -20 to 60°C, less than 60°C/70%RH

    Dimensions

    162 (W) × 70 (H) × 260 (D) mm

    6.38 (W) × 2.76(H) × 10.25 (D) inch

    (exclude projections and stand)

    Weight

    approx. 4lbs (1.8kg), including battery
    approx. 3.3lbs (1.5kg) without battery



    Categories
    Power Supplies
    Generators
    Spectrum Analyzers
    Oscilloscopes
    Component Testers
    Electronic DC Load
    Multimeters
    Clamp Meters
    Counters
    Environmental Testers
    Electrical Testers
    Cables
    Telephone Testers
    Test Accessories
    Device Programmers
    Battery Analyzers
    Video Testers
    Accessories
    Static Control Products