| Specifications |
| DC Volts | | | Ranges | 200mV, 2V, 20V, 200V, 1000V | | Resolution | 100uV, 1mV, 10mV, 100mV, 1V | | Accuracy | +-(0.5% + 1 Digit) | | Overload Protection | 200 mV Range 500V DC + AC Peak, 350V RMS Sine: All Other Ranges: 1200V DC + AC Peak, 800V RMS, Sine | | Input Impedance | 10 M | | AC Volts | | | Ranges | 200 mV, 2V, 20V, 200V, 750V | | Resolution | 100 uV, 1 mV, 10 mV, 100 mV, 1V | | Basic Accuracy | +-(1.5% + 4 Digits) | | Frequency Response | 50 to 500 Hz | | Overload Protection | 200 mV Range: 500 VDC + AC Peak, 350V RMS, Sine: All Other Ranges: 1200 V DC + AC Peak, 800V RMS, Sine: | | Input Impedance | 10 M | | DC Current | | | Ranges | 200 mA, 20 mA, 200mA, 10A | | Resolution | 0.1uA, 1uA, 100 uA, 10 mA | | Accuracy | +-(1% + 1 Digit): 10A Range: +-(2% + 3 Digits) | | Burden Voltage | 10A and 200mA range: 750mV max.; All Other Ranges: 325mV max. | | Overload Protection | 10A Range: Unfused: All Other Ranges: 250V Fuse | | AC Current | | | Ranges | 200uA, 2mA, 20mA, 200mA, 2A, 10A (2A: 2706A only) | | Resolution | 0.1uA, 1uA, 10uA, 100uA, 1mA, 10mA, (1 mA: 2706A only) | | Accuracy | +-(1.2% + 4 digits): 10A Range: +-(2% + 4 Digits) | | Frequency Response | 50 to 500 Hz | | Burden Voltage | 10A and 200mA Range: 750mV max.: All Other Ranges: 325mV max. | | Overload Protection | 10A Range: Unfused; All Other Ranges: 250V Fuse | | Resistance | | | Ranges | 200 , 2kOhm, 20kOhm, 200kOhm, 2MOhm, 20MOhm, 200MOhm (200MOhm: 2707A only) | | Resolution | 0.1 , 1Ohm, 10Ohm, 100Ohm, 1 kOhm, 10 kOhm, 100 kOhm (100kOhm: 2707A only) | | Basic Accuracy | 200 M Range (2707A only): +-(5% + 10 Dgt.); +-(0.8% + 1 Digit) | | | 20 M Range: +-(3% + 1 Digit) | | Overload Protection | 500 VDC + AC Peak | | Diode Test | Tested at 1.6mA and 3.2V Max. | | Transistor Test (hFE) | Base Current: 10 uA Vce; 2.8V; Gain Indication: 0 to 1,000 | | Capacitance | | | Ranges | 2,000 pF, 20 nF, 200 nF, 2 uF, 20 uF | | Resolution | 1 pF, 10 pF, 100 pF, 1 nF, 10 nF | | Accuracy | +-(3% + 10 Digits) | | Test Frequency, Voltage | 400 Hz, 50 mV | | Frequency | | | Ranges | 2 kHz, 20 kHz, 200 kHz, 2 MHz, 15 MHz | | Resolution | 1 Hz, 10 Hz, 100 Hz, 1kHz, 10kHz | | Accuracy | +-(0.1% + 2 Digit) | | Sensitivity | 1Vrms | | Overload Protection | 500V DC + AC Peak | | Logic Probe (TTL) | | | Logic Threshold | Does not apply | | Minimum Pulse Width | | | Input Impedance | | | Overload Protection | | | Temperature | | | Range | Does not apply | | Accuracy | | | -4 0 to + 900 0 F (-20 0 to 500 0 C) | | 900 0 to + 1400 0 F (500 0 to + 750 0 C) | | | Continuity Tone | Tone Sounds within 100 mS for Resistance Under 100V | | General | | | Display | 3 1/2 digit, high-contrast 0.7'' LCD, 1999 counts | | Sampling | 3 times/sec. (nominal) | | Operating Temp: | 32 0 to 104 0 F (0 0 to + 40 0 C), 0 to 70% RH | | Storage Temp | -4 0 to 140 0 F (-20 0 to 60 0 C), 0 to 80% RH | | Power Requirements | 9V NEDA 1604. | | Battery Life | 200 hours (alkaline) nominal 275 hours (alkaline) Nominal (2703B only) | | Dimensions (HxWxD) | 5.9x3.1x1.3'' (150x79x33 mm) | | One Year Warranty | | Accessories | SUPPLIED: Battery, Test Leads, Instruction Manual, Thermocouple Probe (2706A only) OPTIONAL: TL-2A Deluxe Test Leads, TL-3 Accessory Tip Kit (for TL-2A), PR-28A High Voltage DMM Probe (40kVDC), TL-130A General Purpose DMM Kit Carrying Case (not included): LC-29B |
|
|