| Volts | |
| DC Ranges | 400 mV, 4V, 40V, 400V, 1000V |
| AC Ranges | 400 mV, 4V, 40V, 400V, 750V |
| Resolution | 100uV, 1 mV, 10 mV, 100 mV, 1 V |
| DC Accuracy | +-(0.5% rdg + 1 dgt) |
| AC Accuracy | +-(1.2%rdg + 4 dgt) |
| | 750V: +- (2% rdg + 4 dgt) |
| | +-(1.5% rdg + 3 dgt) 500 Hz-1kHz |
| Overload Protection | 1200VDC or AC rms |
| | 500VDC/AC rms 15 sec |
| | on 200mV range |
| Input Impedance | 10M |
| Current | |
| Ranges | 400 mA, 4 mA, 40 mA, 400 mA, 2A, 20A* |
| Resolution | 100 nA, 1 uA, 10 uA, 100 uA, 1 mA, 10 mA |
| DC Accuracy | 400 uA - 400 mA: +-(1% rdg + 1 dgt) 2A: +-(1.5% rdg + 1 dgt) 20A: +-(3% rdg + 3 dgt) |
| AC Accuracy | 400 uA - 400 mA: +-(1.5% rdg + 1 dgt) 2A: +-(2% rdg + 4 dgt) 20A: +-(3.5% rdg + 4 dgt) |
| Input Protection | uA/mA input: 2A/600V fastblow ceramic fuse 20A input: 20A/600V fastblow ceramic fuse |
| Max. Burden Voltage | 600mV (900 mV on 2A, 20A ranges) |
| Resistance | |
| Ranges | 400 , 4 kOhm, 40 kOhm, 400 kOhm, 4 MOhm, 40 MOhm |
| Resolution | 100 m , 1 Ohm, 10 Ohm, 100 Ohm, 1 kOhm, 10 kOhm |
| Accuracy | 400 : +-(1% rdg + 4 dgt.) 4 k to 4 MOhm: +-(0.8% rdg + 4 dgt.) 40 M : +-(2% rdg + 5 dgt.) |
| Open Circuit Voltage | 0.6 VDC typ. (3.2 VDC on 400 range) |
| Overload Protection | |
| Diode Test | Tested at 1 mA, 3.2 VDC max. typ. +-(1.5% rdg + 3 dgt.) accuracy |
| Transistor Test (hFE) | hFE range: 0 - 1000 hFE base current: 10 uA DC |
| Capacitance | |
| Ranges | 4 nF, 40 nF, 400 nF, 4 uF, 40 uF |
| Resolution | 0.1 pF, 1 pF, 10 pF, 100 pF, 1 nF |
| Accuracy | +-(3% rdg + 4 dgt.) |
| Test Voltage | < 3.5V |
| Overload Protection | 500 VDC or AC rms |
| Frequency | |
| Ranges | 4 kHz, 40 kHz, 400 kHz, 4 MHz |
| Resolution | 1 Hz, 10 Hz, 100 Hz, 10 kHz |
| Accuracy | +-(0.1% rdg + 2 dgt.) |
| Sensitivity | 250 V rms min. on 10 Hz to 1 MHz 500 mV rms min. on 1 MHz to 4 MHz |
| Minimum Pulse Width | > 2 us |
| Duty Cycle Limits | > 30% & <70% |
| Minimum Input Range | |
| Overload Protection | 500 VDC or AC rms |
| Logic Test | |
| Logic Threshold | Hi=2.8+-0.8V, 0=0.8 +-0.5V |
| Frequency Response | 20 MHz |
| Pulse Width | 25 ns |
| Pulse Limits | > 20% and < 80% |
| Indication | 40m sec beep at logic 1 (Hi) |
| Overload Protection | 500 V DC or AC rms |
| Temperature | |
| Range, Resolution | Does not apply |
| Accuracy | |
| Duty Cycle | |
| Range, Resolution | Does not apply |
| Accuracy (5V logic) | |
| Minimum Pulse Width | |
| Frequency Range | |
| Overload Protection | |
| General | |
| Display | 4000 count, 3 3/4 digit LCD |
| Polarity | Automatic, positive implied, negative polarity indication |
| Operating Temperature | 32 0 to 122 0 (0 0 to 50 0 C), 0 to 70% R.H. |
| Dimensions (HxWxD) | 7.8x3.5x1.57'' (198x90x40 mm) |
| Weight | 11.3 oz. (320g) |
| Three Year Warranty |
| Accessories |
SUPPLIED: 9V Battery, Test Leads, Instruction Manual, Thermocouple Probe (Model 390) OPTIONAL: TL-2A Deluxe Test Leads, TL-3 Accessory Tip Kit (for TL-2A), PR-28A High Voltage Probe (40kVDC), TL-130A General Purpose DMM Kit Carrying Case (not included): LC-29B |
| *10 A continuous, 20A for 30 seconds max. |