The Dual Display Multimeter model 5492 is a 5 1/2 digit multimeters with selectable count resolutions up to 120,000 count. It is designed for bench-top, field service, and system applications with a high performance to price ratio. One set of TL 36 Test Leads and AC 01 caps for TL 36 are included with each 5492. Selectable count resolutions of 120,000, 40,000 and 4,000 count Selectable 2 wire and 4 wire resistance measurements Measure frequency to 1MHz with 0.01Hz best resolution RS-232 interface GPIB option available (order model 5492GPIB)
List Price: $715.00
Add to Cart

 Expand  Specifications

Specifications assumptions:

    One-year calibration cycle. Operating temperature at 18 °C to 28°C (64.4°F to 82.4°F). Accuracy is expressed as: ± % of reading + digits) after 30 minutes warm-up. Temperature coefficient: Add ± [0. 15 x (the applicable accuracy)/°C] for 0°C to 18°C and 28°C to 50°C. Relative Humidity (RH) up to 80% for 0 °C to 28°C (75% RH for 12M �Ohm and above ranges of resistance measurement); up to 70% for 28°C to 35°C; up to 50% for 35°C to 50°C All specifications are specified under single display mode in operation only.

Display Counts and Reading Rates

Full Scale Display Counts

Slow

Medium

Fast

119,999

39,999

3,999

Reading Rates on Single Display (Readings/Sec)

Measurement Functions

Slow

Medium

Fast

DCV

2

5

20

DCA

2

5

20

Diode

2

5

20

ACV

2

4.2

20

ACA

2

4.2

20

2-wires �Ohm

2

4

17

4-wires �Ohm 4M Ohm/1.2M Ohm range and below

0.6

0.8

0.9

4-wires �Ohm 12M Ohm range and above

1.4

1.7

1.9

Frequency

1.2

1.7

2.4

ACV+DCV

0.4

0.5

0.7

ACA+DCA

0.4

0.5

0.7

Reading Rates on Dual Display (Readings/Sec)

Measurement Functions

Slow

Medium

Fast

DCV / ACV

0.7

1.0

1.9

DCA / ACA

0.7

1.0

1.9

DCV / DCA

0.7

1.0

1.9

DCV / ACA

0.2

0.2

0.5

ACV / ACA

0.2

0.2

0.5

ACV / DCA

0.7

1.0

1.9

ACV / Frequency

0.5

0.7

1.1

ACA / Frequency

0.6

0.8

1.3

ACV+DCV / DCV

0.5

0.6

0.9

ACA+DCA / DCV

0.1

0.2

0.4

ACA+DCA / ACV

0.1

0.2

0.4

ACA+DCA / DCA

0.5

0.6

0.9

dBm(ACV) / Reference �Ohm

2.1

4.2

11.9

dBm(ACV) / ACV

0.7

1.0

1.7

dBm(ACV) / DCV

0.6

1.0

1.7

dBm(ACV) / Frequency

0.7

1.0

1.7

Note 1: Above table shows some common combinations and applications of using dual display.

Note 2: Using RS-232 or GPIB remote interface, the reading rate approximates to normal mode.

DC Voltage

Resolution, Full Scale Reading and Accuracy

Rate (1)

Range

Resolution

Full Scale
Reading

Accuracy
(1 year)

Typical Input
Impedance (4)

S

120mV
1.2V
12V
120V
1000V

1uV
10uV
100uV
1mV
10mV

119.999
1.19999
11.9999
119.999
1000.00(3)

0.012% + 2
0.012% + 2
0.012% + 2
0.012% + 2
0.012% + 2

10.0M Ohm
10.0M Ohm
11.1M Ohm
10.1M Ohm
10.0M Ohm

M

400mV
4V
40V
400V
1000V

10uV
100uV
1mV
10mV
100mV

399.99
3.9999
39.999
399.99
1000.0(3)

0.012% + 5
0.012% + 5
0.012% + 5
0.012% + 5
0.012% + 5

10.0M Ohm
11.1M Ohm
10.1M Ohm
10.0M Ohm
10.0M Ohm

F

400mV
4V
40V
400V
1000V

100uV
1mV
10mV
100mV
1V

399.9
3.999
39.99
399.9
1000(3)

0.012% + 8 (2)
0.012% + 5
0.012% + 5
0.012% + 5
0.012% + 5

10.0M Ohm
11.1M Ohm
10.1M Ohm
10.0M Ohm
10.0M Ohm

(1) Rate: S (Slow), M (Medium), and F (Fast).
(2) Use relative (REL) modifier.
(3) In Vdc 1000V range, 5% over-range (1050Vdc) is readable.
(4) Input Impedance is in paralleled with capacitance <120pF.

    Maximum input voltage: 1000Vdc or peak ac on any range Response Time: Approximately 1.0 second when the displayed reading reaches 99.9% dc value of the tested input signal at the same range.

Note: When voltage (ac+dc) measurement function is selected, the Vdc input impedance is paralleled with an ac-coupled 1.1M Ohm ac divider.

Noise Rejection Ratio

Rate

CMRR (1)

NMRR (2)

S / M / F

>90dB at dc, 50/60Hz ± 0.1%
(1k OhmUnbalanced)

>50dB at 50/60Hz ± 0.1%

(1) CMRR is the Common Mode Reject Ratio
(2) NMRR is the Normal Mode Rejection Ratio

AC Voltage (True RMS, AC Coupling Mode)

Resolution and Full Scale Reading

Range

Resolution

Full Scale Reading

S

M & F

S

M

F

S

M

F

120mV
1.2V
12V
120V
750V

400mV
4V
40V
400V
750V

1uV
10uV
100uV
1mV
10mV

10uV
100uV
1mV
10mV
100mV

100uV
1mV
10mV
100mV
1V

119.999
1.19999
11.9999
119.999
750.00 (1)

399.99
3.9999
39.999
399.99
750.0 (1)

399.9
3.999
39.99
399.9
750 (1)

(1) In Vac 750V range, 5% over-range (787.5V rms) is readable

Accuracy

Rate

Range

Accuracy (1 year) (1)

20 to 45 Hz

45 to 10k Hz

10 to 30 kHz

30 to 100 kHz

S

120.000mV
1.20000V
12.0000V
120.000V
750.00V

1% + 5
1% + 5
1% + 5
1% + 5 (2)
1% + 5 (2)

0.2% + 5
0.2% + 5
0.2% + 5
0.2% + 5
0.2% + 5

1.5% + 10
1% + 5
1% + 5
1% + 5
1% + 5

5% + 15
3% + 10
3% + 10
3% + 10
3% + 10 (3)

M

400.00mV
4.0000V
40.000V
400.00V
750.0V

1% + 40
1% + 40
1% + 40
1% + 40 (2)
1% + 40 (2)

0.2% + 40
0.2% + 40
0.2% + 40
0.2% + 40
0.2% + 40

1.5% + 80
1% + 40
1% + 40
1% + 40
1% + 40

5% + 120
3% + 80
3% + 80
3% + 80
3% + 80 (3)

F

400.0mV
4.000V
40.00V
400.0V
750V

1% + 100
1% + 100
1% + 100
1% + 100
1% + 100 (2)

0.2% + 100
0.2% + 100
0.2% + 100
0.2% + 100
0.2% + 100

1.5% + 300
1% + 100
1% + 100
1% + 100
1% + 100

5% + 300
3% + 200
3% + 200
3% + 200
3% + 200 (3)

(1) Specified accuracy at input >5% of full scale

(2) For input <200V rms

(3) For input <500V rms

             
    Measurement method: True RMS Maximum Crest Factor: 3.0 at full scale Maximum input voltage: 750V rms, 1100V peak ac
    2x107 V-Hz product on any range, normal mode input
    1x106 V-Hz product on any range, common mode input Input Impedance: 1M Ohm in parallel with capacitance <120pF Response Time: Approximately 1.5 seconds when the displayed reading reaches 99.9% ac rms value of the tested input signal at the same range.

AC Voltage (True RMS, AC+DC Coupling Mode)

Resolution and Full Scale Reading

Range (1)

Resolution

Full Scale Reading

S

M & F

S

M

F

S

M

F

120mV
1.2V
12V
120V
750V

400mV
4V
40V
400V
750V

1uV
10uV
100uV
1mV
10mV

10uV
100uV
1mV
10mV
100mV

100uV
1mV
10mV
100mV
1V

119.999
1.19999
11.9999
119.999
750.00 (2)

399.99
3.9999
39.999
399.99
750.0 (2)

399.9
3.999
39.99
399.9
750 (2)

(1) Vdc and Vac are automatically set at the same range
(2) In Vac 750V range, 5% over-range (787.5V rms) is readable

Accuracy

Rate

Range

Accuracy (1 year) (1)

45 to 10k Hz

10 to 30 kHz

30 to 100 kHz

S

120.000mV
1.20000V
12.0000V
120.000V
750.00V

0.2% + 7
0.2% + 7
0.2% + 7
0.2% + 7
0.2% + 7

1.5% + 12
1% + 7
1% + 7
1% + 7
1% + 7

5% + 18
3% + 12
3% + 12
3% + 12
3% + 12 (2)

M

400.00mV
4.0000V
40.000V
400.00V
750.0V

0.2% + 45
0.2% + 43
0.2% + 43
0.2% + 43
0.2% + 43

1.5% + 83
1% + 43
1% + 43
1% + 43
1% + 43

5% + 125
3% + 83
3% + 83
3% + 83
3% + 83 (2)

F

400.0mV
4.000V
40.00V
400.0V
750V

0.2% + 100
0.2% + 100
0.2% + 100
0.2% + 100
0.2% + 100

1.5% + 300
1% + 100
1% + 100
1% + 100
1% + 100

5% + 300
3% + 200
3% + 200
3% + 200
3% + 200 (2)

(1) Specified accuracy at input >5% of full scale

(2) For input <500V rms

           
    Measurement method: True RMS AC+DC Maximum Crest Factor: 3.0 at full scale Maximum input voltage: 750V rms, 1100V peak ac
    2x107 V-Hz product on any range, normal mode input
    1x106 V-Hz product on any range, common mode input Input Impedance: 1M Ohm in parallel with capacitance <120pF Response Time: Approximately 2.5 seconds when the displayed reading reaches 99.9% (ac+dc) rms value of the tested input signal at the same range.

DC Current

Rate

Range

Resolution

Full Scale Reading

Accuracy (1 year)

Burden Voltage (1)
& Shunt Resistor

S

12mA
120mA
1200mA
12A

0.1uA
1mA
10mA
100mA

11.9999
119.999
1199.99
11.9999

0.1% + 2
0.1% + 2
0.15% + 2
0.2% + 2

<0.15V / 10 Ohm
<1.5V / 10 Ohm
<0.3V / 0.1 Ohm
<0.6V / 0.01 Ohm

M

40mA
120mA
1200mA
12A

1uA
10uA
100uA
1mA

39.999
119.99
1199.9
11.999

0.1% + 6
0.1% + 3
0.15% + 3
0.2% + 3

<0.5V / 10 Ohm
<1.5V / 10 Ohm
<0.3V / 0.1 Ohm
<0.6V / 0.01 Ohm

F

40mA
120mA
1200mA
12A

10uA
100uA
1mA
10mA

39.99
119.9
1199
11.99

0.05% + 15 (2)
0.05% + 5
0.15% + 5
0.2% + 5

<0.5V / 10 Ohm
<1.5V / 10 Ohm
<0.3V / 0.1 Ohm
<0.6V / 0.01 Ohm

(1) Typical at full scale reading and voltage across the input terminals
(2) Use relative (REL) modifier

    Maximum Input and Overload Current Protection (for dc and ac current):
    mA Input Terminal: 1200mA dc or ac rms and protected with 2A/250V, IEC-127 sheet 1 fast blow fuse;
    12A input terminal: 10A dc or ac rms continuous, or 12A dc or ac rms for 30 seconds maximum and protected with 15A/500V, breaking capacity 10,000A fast blow fuse. Response Time: Approximately 1.0 second when the displayed reading reaches 99.9% dc value of the tested input signal at the same range.

AC Current (True RMS, AC Coupling Mode)

Resolution, Full Scale Reading and Burden Voltage

Rate

Range

Resolution

Full Scale Reading

Burden Voltage (1) & Shunt Resistor

S

12mA
120mA
1200mA
12A

0.1uA
1uA
10uA
100uA

11.9999
119.999
1199.99
11.9999

<0.15V / 10 Ohm
<1.5V / 10 Ohm
<0.3V / 0.1 Ohm
<0.6V / 0.01 Ohm

M

40mA
120mA
1200mA
12A

1uA
10uA
100uA
1mA

39.999
119.99
1199.9
11.999

<0.5V / 10 Ohm
<1.5V / 10 Ohm
<0.3V / 0.1 Ohm
<0.6V / 0.01 Ohm

F

40mA
120mA
1200mA
12A

10uA
100uA
1mA
10mA

39.99
119.9
1199
11.99

<0.5V / 10 Ohm
<1.5V / 10 Ohm
<0.3V / 0.1 Ohm
<0.6V / 0.01 Ohm

(1) Typical at full scale reading and rms voltage across the input terminals

Accuracy

Rate

Range

Accuracy (1 year) (1)

20 to 45 Hz

45 to 2k Hz

2 to 10 kHz

S

12mA
120mA
1200mA
12A

1.5% + 5
1.5% + 2
1.5% + 2
2% + 2 (<1.2A)

0.5% + 5
0.5% + 2
0.5% + 2
1% + 2

2% + 10
2% + 5
2% + 5
-

M

40mA
120mA
1200mA
12A

1.5% + 40
1.5% + 12
1.5% + 12
2% + 12 (<1.2A)

0.5% + 40
0.5% + 12
0.5% + 12
1% + 12

2% + 80
2% + 30
2% + 30
-

F

40mA
120mA
1200mA
12A

1.5% + 100
1.5% + 100
1.5% + 100
2% + 100 (<1.2A)

0.5% + 100
0.5% + 100
0.5% + 100
1% + 100

2% + 200
2% + 200
2% + 200
-

(1) Specified accuracy at input >5% of full scale

    Measurement method: True RMS Maximum Crest Factor: 3.0 at full scale Response Time: Approximately 1.5 seconds when the displayed reading reaches 99.9% ac rms value of the tested input signal at the same range.

AC Current (True RMS, AC+DC Coupling Mode)

Resolution, Full Scale Reading and Burden Voltage

Rate

Range

Resolution

Full Scale Reading

Burden Voltage (1)
& Shunt Resistor

S

12mA
120mA
1200mA
12A

0.1uA
1uA
10uA
100uA

11.9999
119.999
1199.99
11.9999

<0.15V / 10 Ohm
<1.5V / 10 Ohm
<0.3V / 0.1 Ohm
<0.6V / 0.01 Ohm

M

40mA
120mA
1200mA
12A

1uA
10uA
100uA
1mA

39.999
119.99
1199.9
11.999

<0.5V / 10 Ohm
<1.5V / 10 Ohm
<0.3V / 0.1 Ohm
<0.6V / 0.01 Ohm

F

40mA
120mA
1200mA
12A

10uA
100uA
1mA
10mA

39.99
119.9
1199
11.99

<0.5V / 10 Ohm
<1.5V / 10 Ohm
<0.3V / 0.1 Ohm
<0.6V / 0.01 Ohm

(1) Typical at full scale reading and rms voltage across the input terminals

Accuracy

Rate

Range

Accuracy (1 year) (1)

45 to 2k Hz

2 to 10 kHz

S

12mA
120mA
1200mA
12A

0.5% + 7
0.5% + 4
0.5% + 4
1% + 4

2% + 12
2% + 7
2% + 7
-

M

40mA
120mA
1200mA
12A

0.5% + 42
0.5% + 15
0.5% + 15
1% + 15

2% + 80
2% + 30
2% + 30
-

F

40mA
120mA
1200mA
12A

0.5% + 100
0.5% + 100
0.5% + 100
1% + 100

2% + 200
2% + 200
2% + 200
-

(1) Specified accuracy at input >5% of full scale

    Measurement range: Vdc and Vac are automatically set at the same range Measurement method: True RMS AC+DC Maximum Crest Factor: 3.0 at full scale Response Time: Approximately 2.5 seconds when the displayed reading reaches 99.9% (ac+dc) rms value of the tested input signal at the same range.

Resistance (2-wire �Ohm and 4-wire �Ohm)

Rate

Range (1)

Resolution

Full Scale Reading

Test
Current

Accuracy (1 year)

2-wire

4-wire

S

120 Ohm
1.2k Ohm
12k Ohm
120k Ohm
1.2M Ohm
12M Ohm
120M Ohm

1m Ohm
10m Ohm
100m Ohm
1 Ohm
10 Ohm
100 Ohm
1k Ohm

119.999
1.19999
11.9999
119.999
1.19999
11.9999
119.999

0.5mA
0.5mA
100mA
10mA
1mA
100nA
10nA

0.1% + 2 (2)
0.08% + 2
0.06% + 2
0.06% + 2
0.15% + 2
1.5% + 2
5.0% + 2

0.05% + 2
0.05% + 2
0.05% + 2
0.05% + 2
0.15% + 2
1.5% + 2
5.0% + 2

M

400 Ohm
4k Ohm
40k Ohm
400k Ohm
4M Ohm
40M Ohm
300M Ohm

10m Ohm
100m Ohm
1 Ohm
10 Ohm
100 Ohm
1K Ohm
10k Ohm

399.99
3.9999
39.999
399.99
3.9999
39.999
299.99

0.5mA
100mA
50mA
5mA
500nA
50nA
10nA

0.1% + 5 (2)
0.08% + 3 (2)
0.06% + 3
0.06% + 3
0.15% + 3
1.5% + 3
5.0% + 5

0.05% + 5 (2)
0.05% + 3
0.05% + 3
0.05% + 3
0.15% + 3
1.5% + 3
5.0% + 5

F

400 Ohm
4k Ohm
40k Ohm
400k Ohm
4M Ohm
40M Ohm
300M Ohm

100m Ohm
1 Ohm
10 Ohm
100 Ohm
1k Ohm
10k Ohm
100k Ohm

399.9
3.999
39.99
399.9
3.999
39.99
299.9

0.5mA
100mA
50mA
5mA
500nA
50nA
10nA

0.1% + 8 (2)
0.08% + 5 (2)
0.06% + 5 (2)
0.06% + 5
0.06% + 5
0.3% + 5
3.0% + 8

0.05% + 8 (2)
0.05% + 5 (2)
0.05% + 5
0.05% + 5
0.05% + 5
0.3% + 5
3.0% + 8

(1) In order to eliminate the noise interference, which might be induced to the test leads, it is recommended to use a shielded test cable for measuring resistance above 120K Ohm.
(2) Use relative (REL) modifier.

    Open Circuit Voltage: < +5.0V dc Zeroing error: 0.05 Ohm or less (excluding test lead resistances) in each range when REL modifier is used Response time: Approximately 1.5 seconds for 12M Ohm and ranges below 12M Ohm; approximately 5 seconds for 40M Ohm range; approximately 10 seconds for 120M Ohm ; approximately 25 seconds for 300M Ohm range. Maximum Input Protection: 500V dc or ac rms

Diode Test/Continuity

Rate

Maximum Reading

Resolution

S

1.19999V

10mV

M

2.4999V

100mV

F

2.499V

1mV

    Open Circuit Voltage: < +5.0V dc Test Current: Approximately 0.5mA dc Audible Tone: Continuous beep for continuity and single tone for normal forward-biased diode or semiconductor junction Continuity level: Approximately below +50mVdc Maximum Input Protection: 500V dc or ac rms

Resistance/Continuity (2-wire)

Rate

Range

Resolution

Maximum Reading

Accuracy

S

120 Ohm

1m Ohm

119.999

0.1% + 2 (1)

M

400 Ohm

10m Ohm

399.99

0.1% + 5 (1)

F

400 Ohm

100m Ohm

399.9

0.1% + 8 (1)

(1) Use relative (REL) modifier

    Open Circuit Voltage: < +5.0V dc Test Current: Approximately 0.5mA dc Audible Tone: Continuous beep for reading is less than 10 Ohm Zeroing error: 0.05 Ohm or less (excluding test lead resistances) in each range when REL modifier is used Maximum Input Protection: 500V dc or ac rms

Frequency

Resolution, Full Scale Reading and Accuracy

Range (Hz)

Measurement Range (Hz)

Resolution (Hz)

Full Scale Reading

Accuracy (1 year) (1)

Input Sensitivity (Sine wave)

1200

5 to 1200

10m

1199.99

0.005 + 3

40mV rms

12k

10 to 12k

100m

11.9999

0.005 + 2

120k

100 to 120k

1

119.999

0.005 + 2

1M (2)

1k to 1M

10

1.19999

0.005 + 2

0.5V rms

(1) Specified accuracy at input >5% of full scale
(2) If tested frequency is greater than 1MHz, it will be displayed but no specified accuracy is guaranteed.

    Measurement method: True RMS Maximum Crest Factor: 3.0 at full scale Maximum input voltage: 750V rms, 1100V peak ac
    2x107 V-Hz product on any range, normal mode input
    1x106 V-Hz product on any range, common mode input Input Impedance: 1M Ohm in parallel with capacitance <120pF Response Time: Approximately 1.2 seconds when the displayed reading reaches 99.9% frequency value of the tested input signal at the same range.

dBm (decibel calculation)

Reference Impedance (1)

2 Ohm (2)
4 Ohm (2)
8 Ohm (2)
16 Ohm (2)

 

50 Ohm
75 Ohm
93 Ohm
110 Ohm
124 Ohm
125 Ohm

135 Ohm
150 Ohm
250 Ohm
300 Ohm
500 Ohm
600 Ohm (3)

800 Ohm
900 Ohm
1000 Ohm
1200 Ohm
8000 Ohm
 

(1) Reference impedance is displayed on the secondary display
(2) Reading displayed in watts (Audio Power)
(3) Default reference impedance

Range and Accuracy

Rate

Voltage
Range (1,2)

Input Voltage

dBm (3) Range
@ 600 Ohm Ref

Accuracy (dB)

20 to 45 Hz

45 to 10 kHz

0 to 100 kHz

S

120mV
1.2V
12V
120V

6mV ~ 120mV
120mV ~ 1.2V
1.2V ~ 12V
12V ~ 120V

-42.20 ~ -16.20
-16.20 ~ 3.80
3.80 ~ 23.80
23.80 ~ 43.80

1.0
0.8
0.8
0.8

0.2
0.1
0.1
0.1

1.0
0.8
0.8
0.8

1000V (dc)
750V (ac)

120V ~ 1000V
120V ~ 750V

43.80 ~ 62.22
43.80 ~ 59.72

-

1.0(4)

-

M & F

400mV
4V
40V
400V

20mV ~ 400mV
400mV ~ 4V
4V ~ 40V
40V ~ 400V

-31.76 ~ -5.74
-5.74 ~ 14.26
14.26 ~ 34.26
34.26 ~ 54.26

1.0
0.8
0.8
0.8

0.2
0.1
0.1
0.1

1.0
0.8
0.8
0.8

1000V (dc)
750V (ac)

400V ~ 1000V
400V ~ 750V

54.26 ~ 62.22
54.26 ~ 59.72

-

1.0(4)

-

(1) Auto-ranging is used when dBm function is selected
(2) In Vac 750V range, 5% over-range is readable
(3) Reading displayed in dB when REL modifier is used
(4) For input voltage at frequency between 45Hz to 1kHz

    0dBm: 1 m Ohm @ 600 Ohm Reference Impedance Resolution: 0.01dB at slow and medium rate; 0.1dB at fast rate for all ranges. CMRR: > 90dB for dc signal Response Time: Same as ac voltage and ac current measurements.

A-3 General Specifications

General Items

Specifications

�Ohmarm up time

At least 30 minutes

Temperature Coefficient
 

Add 0.15 x (the applicable accuracy)/°C at 0°C to 18°C and 28°C to 50°C

Operating Temperature

0°C to 50°C (32°F to 122°F)

Storage Temperature

-20°C to 60°C

Altitude

Up to 2000 M

Pollution Degree

II

Over-voltage Category

CAT II-600V and CAT I-1000V

Relative Humidity
 
 
 

�  Up to 80% for 0°C to 28°C (75% RH for 12M Ohm and above ranges of resistance measurement)
�  Up to 70%for 28°C to 35°C
�  Up to 50%for 35°C to 50°C

Common Mode Voltage
 

1000V dc or peak ac rms maximum between any input and earth ground

Dimension

Approx. 255(w) x 105(h) x 305(d) mm (with holsters)

�Ohmeight

<3.0kgs

Line Voltage

100V / 120V / 220V / 240V ac ±10%, 50/60Hz, 16VA maximum

Interface
 
 
 
 
 
 

�  RS-232 (DB-9, male connector)
�  Baud rates: 9600, 4800, 2400, 1200, 600, 300
�  Data length: 7 or 8 bits
�  Parity: even / odd / none
�  Stop bit: 1 or 2 bits
�  Echo: on / off
�  Print mode: on / off

Safety Requirement

Designed in compliance with EN61010-1 (IEC1010-1)

Installation Category
 

CAT-I 750VAC/1000VDC or CAT-II 600V,Pollution Degree 2 Environment

EMC Requirement

Designed in compliance with EN61326-1.



Categories
Accessories
Analyzers
Backup Power (UPS)
Battery Analyzers
Cable Testers
Cables
Calibrators
Clamp Meters
Component Testers
Counters
Device Programmers
Electrical Testers
Electronic DC Load
Environmental Testers
Generators
Inspection Tools
Multimeters
Oscilloscopes
Power Supplies
Specialty Meters
Spectrum Analyzers
Static Control Products
Telephone Testers
Thermal Imaging
Video Testers