BK Precision 889A - Bench LCR/ESR Meter with Component Tester

889A - Bench LCR/ESR Meter with Component Tester
Click to zoom

BK Precision 889A - Bench LCR/ESR Meter with Component Tester
The B&K Precision Model 889A Synthesized In-Circuit LCR/ESR Meter with Component Tester is a high accuracy test instrument used for measuring inductors, capacitors and resistors with a basic accuracy of 0.1%. Also, with the built-in functions of DC/AC Voltage measurements and Diode/Audible Continuity checks, the Model 889A can not only help engineers and students to understand the characteristic of electronics components but also being an essential tool on any service bench.
List Price: $1,425.00
Add to Cart

 Expand  Specifications
Measuring Range
ParameterRange
Z0.000 Ω to 500.0 MΩ
L0.030 µH to 9999 H
C0.003 pF to 80.00 mF
DCR0.000 Ω to 500.0 MΩ
ESR0.000 Ω to 9999 Ω
D0.000 to 9999
Q0.000 to 9999
θ-180.0 ° to 180.0 °
Voltage/Current Measurements
V0.0 mV to +/- 600 V
A0.000 mA to +/- 2 A
Accuracy (Ae)

1. DC Voltage Measurement

Range2V, 20V, 200V, and 600V
Resolution1mV, 10mV, 100mV, and 1V
Accuracy+/- (0.4% + 3 digits)
Input Impedance1 MΩ

2. AC Voltage Measurement (True RMS)

Range2V, 20V, 200V, and 600V
Resolution1mV, 10mV, 100mV, and 1V
Accuracy+/- (0.8% + 5 digits)
Input Impedance1 MΩ

3. DC Current Measurement

Range2mA, 20mA, 200mA, and 2000mA
Resolution1µA, 10µA, 100µA, and 1mA
Accuracy+/- (0.4% + 3 digits)
Current Shunt0.1 Ω @ >20mA, 10 Ω @ ≤20mA

4. AC Current Measurement (True RMS)

Range2mA, 20mA, 200mA, and 2000mA
Resolution1µA, 10µA, 100µA, and 1mA
Accuracy+/- (0.8% + 5 digits)
Current Shunt0.1 Ω @ >20mA, 10 Ω @ ≤20mA
Note: The accuracy of DC/AC voltage/current measurements is only applied when in 5% - 100% of the range.

5. LCR Measurement

Z Accuracy (Ae)

Freq.|Zx|
20M ∼ 10M (Ω)10M ∼ 1M (Ω)1M ∼ 100K (Ω)100K ∼ 10K (Ω)10K ∼ 1K (Ω)1K ∼ 100 (Ω)100 ∼ 1 (Ω)1 ∼ 0.1 (Ω)
DCR2% ±1
(*)
1% ±10.5% ±10.2% ±10.1% ±10.2% ±10.5% ±11% ±1
(*)
100Hz  
120Hz  
1KHz  
10KHz5% ±1
(*)
2% ±1  
100KHz
200KHz
(*)
NA5% ±12% ±11% ±10.4% ±11% ±12% ±15% ±1
Note:
1. The accuracy applies when the test level is set to 1Vrms.
2. Ae multiplies 1.25 when the test level is set to 250mVrms.
3. Ae multiplies 1.50 when the test level is set to 50mVrms.
4. When measuring L and C, multiply Ae by (1 + Dx2)1/2 if the Dx>0.1.
(*): Ae is applied only when the test level is set to 1Vrms.

C Accuracy

100Hz79.57pF | 159.1pF159.1pF | 1.591nF1.591nF | 15.91nF15.91nF | 159.1nF159.1nF | 1.591µF1.591µF | 15.91µF15.91µF | 1591µF1591µF | 15.91mF
2% ±1
(*)
1% ±10.5% ±10.2% ±10.1% ±10.2% ±10.5% ±11% ±1
(*)
120Hz66.31pF | 132.6pF132.6pF | 1.326nF1.326nF | 13.26nF13.26nF | 132.6nF132.6nF | 1.326µF1.326µF | 13.26µF13.26µF | 1326µF1326µF | 13.26mF
2% ±1
(*)
1% ±10.5% ±10.2% ±10.1% ±10.2% ±10.5% ±11% ±1
(*)
1KHz7.957pF | 15.91pF15.91pF | 159.1pF159.1pF | 1.591nF1.591nF | 15.91nF15.91nF | 159.1nF159.1nF | 1.591µF1.591µF | 159.1µF159.1µF | 1.591mF
2% ±1
(*)
1% ±10.5% ±10.2% ±10.1% ±10.2% ±10.5% ±11% ±1
(*)
10KHz0.795pF | 1.591pF1.591pF | 15.91pF15.91pF | 159.1pF159.1pF | 1.591nF1.591nF | 15.91nF15.91nF | 159.1nF159.1nF | 15.91uF15.91uF | 159.1µF
5% ±1
(*)
2% ±10.5% ±10.2% ±10.1% ±10.2% ±10.5% ±11% ±1
(*)
100KHz
(*)
NA0.159pF | 1.591pF1.591pF | 15.91pF15.91pF | 159.1pF159.1pF | 1.591nF1.591nF | 15.91nF15.91nF | 1.591µF1.591µF | 15.91µF
NA5% ±12% ±11% ±10.4% ±11% ±12% ±15% ±1
200KHz
(*)
NA0.079pF | 0.795pF0.795pF | 7.957pF7.957pF | 79.57pF79.57pF | 795.7pF795.7pF | 7.957nF7.957nF | 795.7nF795.7nF | 7.957µF
NA5% ±12% ±11% ±10.4% ±11% ±12% ±15% ±1

L Accuracy

100Hz31.83KH | 15.91KH15.91KH | 1591H1591H | 159.1H159.1H | 15.91H15.91H | 1.591H1.591H | 159.1mH159.1mH | 1.591mH1.591mH | 159.1µH
2% ±1
(*)
1% ±10.5% ±10.2% ±10.1% ±10.2% ±10.5% ±11% ±1
(*)
120Hz26.52KH | 13.26KH13.26KH | 1326H1326H | 132.6H132.6H | 13.26H13.26H | 1.326H1.326H | 132.6mH132.6mH | 1.326mH1.326mH | 132.6µH
2% ±1
(*)
1% ±10.5% ±10.2% ±10.1% ±10.2% ±10.5% ±11% ±1
(*)
1KHz3.183KH | 1.591KH1.591KH | 159.1H159.1H | 15.91H15.91H | 1.591H1.591H | 159.1mH159.1mH | 15.91mH15.91mH | 159.1µH159.1µH | 15.91µH
2% ±1
(*)
1% ±10.5% ±10.2% ±10.1% ±10.2% ±10.5% ±11% ±1
(*)
10KHz318.3H | 159.1H159.1H | 15.91H15.91H | 1.591H1.591H | 159.1mH159.1mH | 15.91mH15.91mH | 1.591mH1.591mH | 15.91µH15.91µH | 1.591µH
5% ±1
(*)
2% ±10.5% ±10.2% ±10.1% ±10.2% ±10.5% ±11% ±1
(*)
100KHz
(*)
31.83H | 15.91H15.91H | 1.591H1.591H | 159.1mH159.1mH | 15.91mH15.91mH | 1.591mH1.591mH | 159.1µH159.1µH | 1.591µH1.591µH | 0.159µH
NA5% ±12% ±11% ±10.4% ±11% ±12% ±15% ±1
200KHz
(*)
15.91H | 7.957H7.957H | 795.7mH795.7mH | 79.57mH79.57mH | 7.957mH7.957mH | 795.7µH795.7µH | 79.57µH79.57µH | 0.795µH0.795µH | 0.079µH
NA5% ±12% ±11% ±10.4% ±11% ±12% ±15% ±1

D Accuracy

Freq.|Zx|
20M ∼ 10M (Ω)10M ∼ 1M (Ω)1M ∼ 100K (Ω)100K ∼ 10K (Ω)10K ∼ 1K (Ω)1K ∼ 100 (Ω)100 ∼ 1 (Ω)1 ∼ 0.1 (Ω)
100Hz±0.020
(*)
±0.010±0.005±0.002±0.002±0.002±0.005±0.010
(*)
120Hz  
1KHz  
10KHz±0.050
(*)
±0.020  
100KHz
200KHz
(*)
NA±0.050±0.020±0.010±0.004±0.010±0.020±0.050

θ Accuracy

Freq.|Zx|
20M ∼ 10M (Ω)10M ∼ 1M (Ω)1M ∼ 100K (Ω)100K ∼ 10K (Ω)10K ∼ 1K (Ω)1K ∼ 100 (Ω)100 ∼ 1 (Ω)1 ∼ 0.1(Ω)
100Hz±1.046
(*)
±0.523±0.261±0.105±0.105±0.105±0.261±0.523
(*)
120Hz  
1KHz  
10KHz±2.615
(*)
±1.046  
100KHz
200KHz
(*)
NA±2.615±1.046±0.409±0.209±0.409±1.046±2.615

Z Accuracy
 As shown in table 1.

C Accuracy
 |Zx| = 1/(2·π·ƒ·Cx)

 CAe = Ae of C
 f: Test Frequency (Hz)
 Cx: Measured Capacitance Value (F)
 |Zx|: Measured Impedance Value (Ω)
 Accuracy applies when Dx (measured D value) ≤0.1
 When Dx > 0.1, multiply CAe by (1 +  Dx2)1/2

 Example:
 Test Condition:

   Frequency:   1KHz
   Level:   1Vrms
   DUT:   100nF

 Then
 |Zx| = 1/(2·π·ƒ·Cx) = 1/(2·π·103·100·10-9) = 1590 Ω

 Refer to the accuracy table, get CAe=±0.1%

L Accuracy
 |Zx| = 2·π·ƒ·Lx

 LAe = Ae of L
 f: Test Frequency (Hz)
 Lx: Measured Inductance Value (H)
 |Zx|: Measured Impedance Value (Ω)
 Accuracy applies when Dx (measured D value) ≤0.1
 When Dx > 0.1, multiply LAe by (1 + Dx2)1/2

 Example:
 Test Condition:

   Frequency:   1KHz
   Level:   1Vrms
   DUT:   1mH

 Then
 |Zx| = 2·π·ƒ·Lx = 2·π·103·10-3 = 6.283Ω

 Refer to the accuracy table, get LAe = ±0.5%

ESR Accuracy
 ESRAe = ±Xx·Ae/100
 Xx = 2·π·ƒ·Lx = 1/(2·π·ƒ·Cx)

 ESRAe = Ae of ESR
 f: Test Frequency (Hz)
 Xx: Measured Reactance Value (Ω)
 Lx: Measured Inductance Value (H)
 Cx: Measured Capacitance Value (F)
 Accuracy applies when Dx (measured D value) ≤0.1

 Example:
 Test Condition:

   Frequency:   1KHz
   Level:   1Vrms
   DUT:   100nF

 Then
 |Zx| = 1/(2·π·ƒ·Cx) = 1/(2·π·103·100·10-9) = 1590Ω

 Refer to the accuracy table, get
 CAe=±0.1%,
 ESRAe = ±Xx·Ae/100 = ±1.59Ω

D Accuracy
 DAe = ±Ae/100

 DAe = Ae of D measurement value
 Accuracy applies when Dx (measured D value) ≤0.1
 When Dx > 0.1, multiply Dx by (1+Dx)

 Example:
 Test Condition:

   Frequency:   1KHz
   Level:   1Vrms
   DUT:   100nF

 Then
 |Zx| = 1/(2·π·ƒ·Cx) = 1/(2·π·103·100·10-9) = 1590Ω

 Refer to the accuracy table, get
 CAe=±0.1%,
 DAe = ±Ae/100 = ±0.002

Q Accuracy
 QAe = ±(Qx2·De)/(1-/+(Qx·De))

 QAe = Ae of Q measurement value
 Qx: Measured Quality Factor Value
 De: Relative D Accuracy
 Accuracy applies when Qx·De <1

 Example:
 Test Condition:

   Frequency:   1KHz
   Level:   1Vrms
   DUT:   1mH

 Then
 |Zx| = 2·π·ƒ·Lx = 2·π·103·10-3 = 6.283Ω

 Refer to the accuracy table, get
 LAe=±0.5%,
 De = ±Ae/100 = ±0.005

 If measured Qx = 20

 Then
 QAe = ±(Qx2·De)/(1-/+(Qx·De)) = ±2/(1-/+0.1)

θ Accuracy
 θAe = 180/π·Ae/100

 Example:
 Test Condition:

   Frequency:   1KHz
   Level:   1Vrms
   DUT:   100nF

 Then
 |Zx| = 1/(2·π·ƒ·Cx) = 1/(2·π·103·100·10-9) = 1590Ω

 Refer to the accuracy table, get
 ZAe=±0.1%,
 θAe = ±(180/π·Ae/100) = ±(180/π·0.1/100) = ±0.057 °

Testing Signal
 Level Accuracy:±10%
 Frequency Accuracy:0.1%
Output Impedance:100 Ω ±5%
General
 Temperature:0°C to 70°C (Operating)
-20°C to 70°C (Storage)
 Relative Humidity:Up to 85%
 AC Power:110/220V, 60/50Hz
 Dimensions (L x W x H):300mm x 220mm x 150mm, 11.8" x 8.7" x 5.9"
 Weight:4500g


Categories
Accessories
Analyzers
Backup Power (UPS)
Battery Analyzers
Cable Testers
Cables
Calibrators
Clamp Meters
Component Testers
Counters
Device Programmers
Electrical Testers
Electronic DC Load
Environmental Testers
Generators
Inspection Tools
Multimeters
Oscilloscopes
Power Supplies
Specialty Meters
Spectrum Analyzers
Static Control Products
Telephone Testers
Thermal Imaging
Video Testers