GeneralSpecific | Display | Dual Display; 4-digit, 10,000 count (0 to 9999) LCD |
| Jaw Opening | 1.6" (42mm) |
| Max. Input limit | Max. voltage between any terminal and ground: 600Vrms |
| Sampling rate | 2.5 times per second (Digital Display); Once every 6 seconds (KW, KVA, and KVAR) |
| Auto Sleep | After approx. 30 minutes (feature can be defeated) |
| Low battery indication | Battery symbol appears on the LCD |
| Power supply | 9V Battery |
| Battery life | Approx. 32 hours with alkaline battery |
| Operating Temperature | 32 to 122oF (0 to 50oC) |
| Operating Humidity | < 80% RH |
| Operating Altitude | 7000 ft. (2000 meters) maximum. |
| Storage Temperature | 14 to 140oF (-10 to 60oC) |
| Storage Humidity | < 70% RH |
| Temperature coefficient | 0.1 x (specified accuracy) / oC at < 64oF (18oC), >82oF (28oC) |
| Approvals | CE, UL |
| Safety | This meter is intended for indoor use and protected, against the users, by double insulation per EN61010-1 and IEC61010-1 2nd Edition (2001) to CAT III 600V; Pollution Degree 2. The meter also meets UL 61010A-1, First Edition |
| UL Listed | The UL mark does not indicate that this product has been evaluated for the accuracy of its readings. |
| Function | Max Range / Resolution | Basic Accuracy |
| True Power (W) | 600kW / 10W | ±5%+ 20d |
| Apparent Power(kVA) | 600kVA / 10kVA | ±2%+ 20d |
| Reactive Power (kVAR) | 600kVAR/10VAR | ±5%+ 20d |
| Horsepower (HP) | 800HP/0.01HP | ±5%+ 20d |
| Phase Angle (f) | -60 to +60° / 0.1° | ±6° |
| AC Current | (Trms): 1000A / 10mA | ±2%+ 20d |
| uA Current (AC+DC) (Trms) | 1000ìA / 10nA | ±1%+ 20d |
| AC/DC Voltage | (Trms): 600V / 0.1mV | ±1%+ 20d |
| Resistance (½) | 1000ω / 0.1ω | ±1%+ 10d |
| Resistance (M½) | 100Mω / 1kω | ±5%+ 10d |
| Capacitance | 7000ìF / 1nF | ±1.5%+ 5d |
| Frequency | 40Hz to 1kHz / 0.1Hz | ±0.5%+ 2d |
| Temperature (Type K) | -58 to 1000°F / 0.1°F -50 to 900°C / 0.1°C | ±1%+ 2°F ±1%+ 1°C |
| Dimensions | 9 x 3 x 1.6" (228 x 76 x 39mm) |
| Weight | 16.4oz (465g) |
ations: