| Resistance Test Frequency | 1.667KHz (15mV rms approx.) |
| Max Conductor size | 0.9" (23mm) |
| Display | 4-digit (9999 count) display |
| Sampling rate | 0.4 seconds |
| Power supply | One 9V battery |
| Power consumption | 40mA |
| Temp. Coefficient | 0.15 times the specified accuracy per degree centigrade (from 39 to 64°F (4 to 18°C) and 82 to 122°F (28 to 50°C)) |
| Current Overload Protected | to 100A Continuous, 200A for less than 60 seconds (50/60Hz) |
| Continuity check | Audible tone if reading is less than approx. 40 Ω |
| Range selection | Automatic ranging |
| Safety | Meets the requirements for IEC1010-1 Category III 300V and Category II 600 V |
| Operating conditions | 4 to 122°F (-20 to 50°C) with < 85% RH |
| Storage conditions | -20 to 140°F (-28 to 60°C) with < 75% RH |
| Dimensions | 10.2 x 4.4 x 1.9" (258 x 110 x 47mm) |
| Weight | 24.7oz (700g) |
| Accessories | Resistance check plate, 9V battery, carrying case |