Extech MM560 - MultiMaster True RMS 50,000/500,000 count, high accuracy of 0.03%, wide bandwidth True RMS multimeter

MM560 - MultiMaster True RMS 50,000/500,000 count, high accuracy of 0.03%, wide bandwidth True RMS multimeter
Click to zoom

Extech MM560 - MultiMaster True RMS 50,000/500,000 count, high accuracy of 0.03%, wide bandwidth True RMS multimeter
Features:
  • 0.03% basic DCV accuracy
  • 50,000 count display with 500,000 counts for DCV and Hz
  • True RMS combination AC+DC function
  • Highest resolution to 1μV, 0.01μA, 0.0001Hz, 0.01Ω
  • 4 to 20mA, displayed as 0-100% for process current measurements

List Price: $239.99
Add to Cart

Specifications
DC LoopCurrent %4 to 20mA - 4mA = 0% (zero), 20mA = 100% (span), Resolution - 0.01%, Accuracy - ±25d
Diode TestAccuracy - 1%+1d, Current 0.8mA(typical), Open circuit - <3.5VDC
Peak Capture (Instantaneous Peak Hold)Accuracy - Specified accuracy ±100 digits for changes > 0.8ms in duration
Audible ContinuityMeasurement threshold - Between 20 Ω and 200 Ω, response time - <100 μs
Accuracy NotesAccuracy is ± (% reading + number of digits), or as otherwise specified, at 23 °C ±5 °C < 75% R.H. True RMS accuracies are specified from 5% to 100% of range or as otherwise specified.
Maximum Crest Factor<5:1 at full scale & <10:1 at half scale with frequency component within the specified frequency bandwidth for non-sinusoidal waveforms.
SensingDC, AC True RMS, AC+DC True RMS
Digital Display4-4/5 digits, 50000 count 5-4/5 digits, 500000 count for DCV 6 digits, 999999 count for Hz
Bar Graph Display42-segment bargraph
PolarityAutomatic
Update rate5 /second for 50,000 count display (fast mode), 1.25/second for 500,000 count display (stable mode), 60 per second for bar graph display
Low BatteryBelow approx. 7V
Operating Temperature41° to 104 °F (5° to 40°C)
Storage Temperature-4° to 140°F (-20 to 60°C)
Relative HumidityMax 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F(40°C), <80% storage
Operating AltitudeBelow 2000 meters
Temp. CoefficientNominal 0.1x(specified accuracy)/°C at(0°C to 18°C or 28°C to 40°C), or otherwise specified
Power Supply9V battery (NEDA1604, JIS006P or IEC6F22)
Power Consumption5mA typical
Auto Power OffAfter 17 minutes of inactivity with no input signal.
Power consumption during auto power off20 μA
SafetyThe MultiMaster Series meters are intended for indoor use and are protected, against the users, by double insulation per EN61010-1 and IEC61010-1 2nd Edition (2001) to CAT III 1000V & CAT IV 600V. The meter (all versions) also meets UL3111-1(1994) and CSA C22.2 No. 1010-1-92 to CAT III 1000V.
Dimension7.32 x 3.43 x 1.4" with holster (186mm x 87mm x 35.5mm)
Weight15.17 oz. with holster (430g)

 



Categories
Accessories
Analyzers
Backup Power (UPS)
Battery Analyzers
Cable Testers
Cables
Calibrators
Clamp Meters
Component Testers
Counters
Device Programmers
Electrical Testers
Electronic DC Load
Environmental Testers
Generators
Multimeters
Oscilloscopes
Power Supplies
Specialty Meters
Spectrum Analyzers
Static Control Products
Telephone Testers
Test Accessories
Thermal Imaging
Video Testers