DC OUTPUT |
| | CH1, CH2 | | |
| Voltage | |
| Current | |
| Tracking Series Voltage | |
| Tracking Parallel Current | |
CONSTANT VOLTAGE OPERATION (CH1, CH2) |
| Line Regulation | < 0.01% + 3mV |
| Load Regulation | < 0.01% + 3mV (rating current <3A) < 0.02% + 5mV (rating current >3A) |
| Ripple & Noise | < 1mVrms 5Hz ~ 1MHz |
| Recovery Time | < 100μS ( 50% Load change, Minimum load 0.5A ) |
CONSTANT CURRENT OPERATION (CH1, CH2) |
| Line Regulation | < 0.2% + 3mA |
| Load Regulation | < 0.2% + 3mA |
| Ripple Current | < 3mArms |
TRACKING OPERATION (CH1, CH2) |
| Tracking Error | < 0.5% + 10mV of CH1 |
| Series Regulation | < 300mV |
| Load Regulation | < 0.01% + 3mV |
| Ripple & Noise | < 2mVrms 5Hz ~ 1MHz |
METER |
| Digital | 3 Digits 0.5" LED Display Accuracy ±(0.5% rdg + 2 digits) |
INSULATION |
| Chassis and Terminal | > DC 500V / 20MΩ |
| Chassis and AC Cord | > DC 500V / 30MΩ |
| POWER SOURCE | |
| |
| | AC 100V/120V/220V ±10%, 230V(+10% ~ -6%), 50/60Hz |
ACCESSORIES |
| | User manual x 1 Power cord x 1 Test lead GTL-104 x 2 European test lead GTL-204 x 2 Sense lead GTL-201A x1 |
| DIMENSIONS & WEIGHT |
| | 255(W) x 145(H) x 265(D)mm, Approx. 7kg |