Extech Instruments Environmental Testers
|

Extech Instruments 392050 - Penetration Stem
Features: - Temperature range: -58 to 302°F (-50 to 150°C)
- Basic Accuracy of 2°F or 1°C
- 0.1° resolution to 199.9; 1° over 200°
- ON/OFF switch saves battery life
- Auto power off after 1hr of non use
Specifications: | Display | 3-1/2 digit LCD with °C/°F degree indicator | | Measurement ranges | -58 to 302°F (-50 to 150°C) | | Auto Off | After one hour of operation | | Resolution | 0.1°C/F from -19.9 to 199.9°F (-20 to 150°C) | | Accuracy | <2°F (1°C) from -14 to 212°F (-50 to 100°C) | | Sensor length | 5.1" (130mm) | | Sensor material | Stainless steel | | Operating temperature | -14 to 122°F (0 to 40°C) | | Battery power | 1.5V LR44 cell (5000 hour approx. life) |
 |

Extech Instruments 392052 - Flat Surface Stem
Features: High temperature range: -58 to 572°F (-50 to 300°C) Basic Accuracy of 2°F or 1°C 0.1° resolution to 199.9; 1° over 200° ON/OFF switch saves battery life Auto power off after 1hr of non use Specifications: | Display | 2000 count liquid crystal display | | Units | °C/°F selectable | | Measurement range | -58 to 572°F (-50 to 300°C) | | Resolution | 0.1°to 199.9°, 1° > 199.9° | | Accuracy | ±1.8°F (1°C) from -22 to 452°F (-30 to 250°C), ±4°F, (2°C) outside this range | | Sensor length | 5" (130mm) | | Sensor tip diameter | 0.57" (14.5mm) | | Sensor material | Stainless steel | | Auto Off | After one hour of operation | | Operating temperature for display | 14 to 122°F (-10 to 50°C) (dial display) | | Battery one | 1.5V LR44 cell or equivalent (A76/G13) cell |
 |

Extech Instruments 392065 - T Bar Stem Thermometer
Features: - 4.9" (124mm) stainless steel probe
- 0.35" (9mm) LCD display
- ON/OFF switch saves battery life
- Temperature: -58 to 302°F (-50 to 150°C); ±2°F/1°C accuracy, 0.1°/1° resolution
- Weight: 0.6oz (17g), 0.8oz (23g) with plastic sheath
- Complete with plastic protective sheath with pocket clip and 1.5V button battery
Specifications: | Ranges | -58 to 302°F (-50 to 150°C) | | Display | 0.35" (9mm) LCD display | | Dimensions | 4.9" (124mm) stainless steel probe | | Weight | 0.6oz (17g), 0.8oz (23g) with plastic sheath | | Accessories | plastic protective sheath with pocket clip and 1.5V button battery | | Accuracy | ±2°F/1°C | | Resolution | 0.1°/1° |
 |

Extech Instruments 392085 - Pocket Thermometer
Features: - Audible alarm alerts user when pre-set max or min temperature is reached or exceeded
- Display Hold function freezes temperature reading on display
- Ranges: -58 to 302°F (-50 to 150°C)
- 0.1° resolution from -19.9 to +199.9° 1° over 200°
- Accurate to ±1.8°F from -58 to 212°F (±1°C from -50 to 100°C)
- Durable 2-1/2" stainless steel probe with 20" cable
- Complete with wallet style case, stainless steel probe, and 1.5V button battery
Specifications: | Measurement Range | -50°C to +150°C or -58°F to +302°F | | Resolution | 0.1° (-19.9° to +199.9°), 1°greater than 199.9° | | Accuracy | ±1.0°C (-50°C to +100°C), ±1.8°C greater than +100°C, ±1.8°F (-58°F to 212°F), ±3.6°F greater then 212°F | | Battery | one 1.5V "A76" size (G13 or equivalent) | | Sensor | 2.5" Stainless steel sensing probe | | Operating temperature | -10°C to +40°C, -50°F to +104°F | | Demensions/weight | 4.8x3x8" (122x76x20mm), 3.4oz. (96g) |
 |
Extech Instruments 39240 - Waterproof Thermometer
Features: - 2.75" (70mm) Stainless steel stem
- °C/°F switchable ranges of -40 to 392°F (-40 to 200°C)
- MAX/MIN recall of high and low temperatures
- Hold and Auto Off features
- Digital display with 0.1° resolution
- Dimensions: 5.9 x 0.8 x 0.7" (150 x 20 x 18mm);
- Weight: 0.7oz (20g)
- Complete with one LR44 button battery and protective cover
Specifications: | Ranges | °C/°F switchable -40 to 392°F (-40 to 200°C) | | MAX/MIN | recall of high and low temperatures | | Features | Hold and Auto Off | | Display | Digital with 0.1° resolution | | Dimensions | 5.9 x 0.8 x 0.7" (150 x 20 x 18mm); | | Weight | 0.7oz (20g) | | Accessories | LR44 button, battery and protective cover | | Accuracy | ±2°F/1°C | | Resolution | 0.1°/1° |
 |
Extech Instruments 39272 - Pocket Fold up Thermometer with Adjustable Probe
Features: - Wide °C/°F switchable temperature range -58 to 572°F (-50 to 300°C)
- Fold up probe 4.5" (114mm) adjusts from 0° to 180° for best measurement and viewing angle
- Large LCD display with 0.1 degree resolution
- Auto power off after 1 hour or when probe is placed in stored position
- Data Hold and Min/Max recordings
- Fast response time - one second under normal conditions
- Complete with wrist strap and one AAA battery
Specifications: | Display | 3-1/2 digit LCD with °C/°F degree indicator | | Measurement ranges | -58 to 572°F (-50 to 300°C) | | Resolution | 0.1°C/F | | Accuracy | ±1.8°F (1°C) from -22 to 482°F (-30 to 150°C) | | Sensor length | 4.5" (117mm) | | Sensor material | Stainless steel | | Operating temperature | -14 to 122°F (-10 to 40°C) | | Battery power | (1)AAA Battery |
 |

Extech Instruments 401012 - Indoor/Outdoor Temperature Alarm
Features: - Large 1.5" LCD displays indoor/outdoor temperature simultaneously from -58 to 158°F, resolution 0.1°F and accuracy to ±1.8°F
- Single Point Alarm (external sensor): set to alarm when temperature is above HI SET or below LO SET point
- Dual Point Alarm (external sensor): set to alarm when temperature is either outside of or within two setpoints
- Audible alarm and Red/Green LED indication for 5 seconds every minute when setpoint(s) is reached
 |

Extech Instruments 401014 - Big Digit Indoor/Outdoor Thermometer
Features: - Large LCD displays 1" (25mm) digits for indoor/outdoor temperature
- Indoor Range: 14 to 140°F (-10 to 60°C)
- Outdoor Range: -58 to 158°F (-50 to 70°C) ±1.8°F /1°C accuracy; 0.1°F/°C resolution
Specifications: | Indoor temperature | 14 to 140°F (-10 to 60°C) | | Outdoor temperature | -58 to 158°F (-50 to 70°C) | | Resolution | 0.1° for F (0.1° for C) | | Accuracy | ±1.8°F (±1°C) from 32 to 122°F (0 to 50°C), ±3.6°F from -58 to 32°F and 122 to 158°F (±2°C from -50 to 0°C and +50 to +70°C) | | Power supply | One (1) 'AAA' 1.5 V battery | | Sensor cable length | Approx. 9' (3m) | | Dimensions | 3.9x4.25x0.75" (99x108x19mm) |
 |

Extech Instruments 401021 - Foot Candle Light MultiMeter Adaptor
Features: - Three ranges (5% accuracy):
- 0 to 5,000Fc
- 1mV/Fc or Lux output
- CE approved .
Specifications: | Accuracy | ± (5% + 1mV) | | Sensor | Exclusive photo diode & color correction filter spectrum designed to meet C. I. E. | | Operating Temperature/humidity | 32°F to 122°F (0C to 50°C) / <90% RH | | Power Supply | 006P DC 9V battery | | Power Consumption | Approx. 6 mA DC | | Low battery indication | Status LED on Front panel of Adaptor | | Dimensions / Weight | 3.9x1.9x1" (100x50x25mm) / 0.33 lbs. (150g) |
 |

Extech Instruments 401025 - Foot Candle/Lux Meter
Features: - Accurately displays light level in terms of Fc or Lux over three ranges
- Select fast (1 second) or slow (2 seconds) response time
- Analog output of 1mV per count for capturing readings to a recorder
Specifications: | Display | 0.5" (13 mm) LCD (Liquid Crystal Display). | | Measurement | Lux, Ft-candle (Fc). | | Ranges | Lux: 0 to 50,000 Lux, 3 ranges. Foot-candle: 0-5,000 Fc, 3 ranges. | | Sensor | Exclusive photo diode & color correction filter, spectrum designed to meet C. I. E. | | Zero Adj. | Manual adjustment. | | Sampling Time | Approx. 0.4 sec. | | Response Time | Fast & Slow selector. | | Over input indication | Indication of "1 " | | Analog Output | 0.1 mV/1 digit, max. output 200mV. | | Operating Temperature | 32°F to 122°F, 0°C to 50°C | | Operating Humidity | Less than 80% RH. | | Power Supply | 006P DC 9V battery | | Power Current | Approx. 2 mA DC | | Weight | 220 g / 0.52 LB | | Dimension Main instrument | 6.4x2.8x1.2 inch (163x70x30mm). | | Sensor Probe | 3.2x2.2x0.5 inch (85x55x12 mm). | | Optional Accessories | Vinyl pouch carrying case, 409996 |
 |

Extech Instruments 403125 - Light Probe Meter
Features: - Backlit display to view in dimly lit areas
- Remote light sensor on 59" (1.5m) cable conveniently mounts on top of meter for one hand operation and safe storage
- Data hold and Peak hold
- Optional analog output cable 403999 allows mV analog output for recording measurements
 |

Extech Instruments 407026 - Heavy Duty Light Meter with PC Interface
Features: % displays differential from reference point "ZERO" Re-Calibration Enhance accuracy by selecting lighting type Tungsten/Daylight, Fluorescent, Sodium, Mercury) Data Hold, Min/Max/Avg readings Built-in RS-232 PC serial interfaceSpecifications: | Circuit | Custom one-chip LSI microprocessor circuit | | Display | 3-1/2 digit (2000 count) LCD display with contrast adjustment | | Measurement ranges | LUX: 0 to 50,000 LUX (3 range); Fc: 0 to 5000 Fc (3 range); Relative mode: 0 to 1999% | | Data Hold | Freezes displayed reading | | Lighting Types | Sodium, Daylight/Tungsten, Fluorescent and Mercury | | Sensor Structure | Cosine/color corrected photo-diode meets C.I.E. | | Memory Store/Recall | Records/Recalls Max/Min/Avg readings | | Sample rate | 0.4 seconds (approx.) per reading | | Zero Adjust | Push-button procedure | | Auto Power Off | After approx. 10 minutes | | Data Output | RS-232 PC serial interface (optional software/cable PN 407001) | | Operating conditions | 32 °F to 122 °F (0 °C to 50 °C); <80% RH | | Power Supply | 9V battery | | Power consumption | Approx. 5 mA DC. (approx. 200 hr battery life) | | Weight | 0.71 lbs. (320 g) | | Dimensions Instrument | 7.1 x 2.8 x1.3" (180 x 72 x 32 mm) | | Sensor | 3.3 x 2.2 x 0.7" (85 x 55 x 17.5 mm) |
 |

Extech Instruments 407113 - Heavy Duty CFM Metal Vane Anemometer
Features: - Display Air Flow (CFM) or Air Velocity plus Temperature
- Air Flow displayed in 3 modes: - Instantaneous value - Up to 20 point average or - 2/3 flow value
- Record and Recall MIN, MAX
- Data Hold plus Auto power off
- Built-in RS-232 PC Interface
Specifications: | Display | Dual Display Multi-function 10,000-count (0 to 9999) LCD | | Measurements | Air Velocity - m/s, km/h, ft/min, knots, mph; Air Flow - CMM (m 3 /min) and CFM (ft 3 /min); Temperature - °C and °F | | Data Hold | Freezes displayed reading | | Sampling rate | One (1) reading per second | | Sensors | Air velocity/flow sensor: Metal angled vane arms with low-friction ball bearing. | | Temp. Sensor | Precision thermistor | | MIN/MAX | Records/Recalls lowest and highest readings | | Auto Power OFF | Automatic shut off after 15 minutes | | PC Interface | RS-232 Serial Communications (16-bit data stream) | | Over range indication | 1___ appears on the LCD | | Low battery indication | LBT appears on the LCD | | Power supply | 9V Battery (consumption 8.3mA approx.) | | Operating conditions Meter | 32 to 122°F (0 to 50°C); 80% RH max. | | Sensor | 32 to 175°F (0 to 80°C) | | Dimensions / Weight Main instrument | 7.1 x 2.8 x1.3" (180 x 72 x 32mm) | | Sensor head | 2.8" (72mm) diameter | | Weight | 0.84 lbs. (381g) for meter and sensor | | m/s (meters per second) | | Range | 0.50 - 40.00 m/s | | Resolution | 0.01 m/s | | Accuracy | ± (2% + 0.2m/s) | | km/h (kilometers per hour) | | Range | 1.8 - 144.0 km/h | | Resolution | 0.1 km/h | | Accuracy | ± (2% + 0.2km/h) | | ft/min (feet per minute) | | Range | 100 - 7880 ft/min | | Resolution | 1 ft/min | | Accuracy | ± (2% + 20ft/min) | | mph (miles per hour) | | Range | 1.1 - 89.4 mph | | Resolution | 0.1 mph | | Accuracy | ± (2% + 0.2m/h) | | knots (nautical miles per hour ) | | Range | 1.0 to 78.1 knots | | Resolution | 0.1 knots | | Accuracy | ± (2% + 0.2knots) | | CMM (cubic meters per minute) | | Range | 0-999,900 m³/min | | Resolution | 0.001 to 100 | | Accuracy | 0 to 9,999m² | | CFM (cubic feet per minute) | | Range | 0-999,900 ft³/min | | Resolution | 0.001 to 100 | | Accuracy | 0 to 9,999ft² | | Air Temperature | | Range | 32 to 175°F (0 to 80°C) | | Resolution | 0.1°F/C | | Accuracy | 1.5°F (0.8°C) |
 |

Extech Instruments 407119 - Heavy Duty CFM Hot Wire Anemometer
Features: Air velocity measurements as low as 40ft/min Telescoping probe is ideal for use in ducts and ventilating systems; extends up to 4ft (1.22m) long 20 point averaging for airflow Record and recall MIN/MAX readings Data Hold plus Auto power off Built-in RS-232 PC Interface Specifications: | Display | Dual function 4-digit LCD | | Measurement units | Air Velocity - m/s, km/h, ft/min, knots, mph; Air Flow - CMM (m³/min) and CFM (ft³/min); Temp - °C and °F | | Data hold | Freezes displayed reading | | Sampling rate | 1 second approx. | | Sensors Air velocity sensor | Glass bead thermistor | | Temperature sensor | Thermistor | | MAX/MIN | Memory Record and view Maximum and Minimum readings | | Automatic Power off | Auto shut off after 15 minutes | | Data Output | RS-232 PC serial interface with 16-bit data stream output | | Operating Temperature Meter | 32 to 122°F (0 to 50°C) | | Sensor | 32 to 176°F (0 to 80°C) | | Operating Humidity Max. | 80% Relative Humidity | | Power Supply | Six (6) ‘AAA' 1.5V batteries | | Power Current | Approx. DC 30mA | | Weight | (meter only) 0.78 lbs. (355g) | | Dimensions Main instrument | 7.1 x 2.8 x1.3" (180 x 72 x 33mm) | | Telescoping Sensor | 0.5" (12.7mm) diameter head; 37" (.94m) maximum antenna length with 78" (2m) cable |
 |
Extech Instruments 407123 - Heavy Duty Hot Wire
Features: - Telescoping probe is ideal for measuring in HVAC ducts and other small vents; extends up to 4ft (1.22m) long
- Super large 1.4" (36mm) dual LCD display
- Min/Max, Data Hold
Specifications: | Circuit configuration | Custom one-chip LSI microprocessor circuit | | Display | 3-1/2 digit (2000 count) dual LCD display | | Measurements | m/s (meters per second), km/h (kilometers per hour), ft/min | | (feet/per minute), knots (nautical miles per hour), MPH (miles per hour), °C, °F | | Data hold | Freezes reading on display | | Sensor | Structure Air velocity sensor: Glass bead thermistor | | Temperature sensor | Precision thermistor | | Min/Max Recording | Record and Recall Maximum (MAX) and Minimum readings | | PC Interface | RS 232 PC serial interface jack for use with Model 407001 software and interface cable kit | | Operating Temperature | 32 to 122°F (0 to 50 °C) | | Operating Humidity | Max. 80% RH | | Power Supply | Six 1.5V ‘AAA' batteries | | Power Consumption | Approx. 30 mADC | | Weight | 0.78 lb (355 g) including batteries & probe | | Dimensions Main instrument | 7.1 x 2.8 x 1.3" (180 x 72 x 32 mm) | | Sensor | 0.5" (12mm) diameter | | Telescope | 3.9' (1.22m) maximum length with cable. | | m/s | | Range | 0.2 to 20.0 m/s | | Resolution | 0.1 m/s | | Accuracy | ± (3% + 1d) of reading or ±(1% + 1d) Full Scale | | (whichever is greater) | | km/h | | Range | 0.7 to 72.0 km/h | | Resolution | 0.1 km/h | | Accuracy | ± (3% + 1d) of reading or ±(1% + 1d) Full Scale | | (whichever is greater) | | ft/min | | Range | 40 to 3940 ft/min | | Resolution | 1 ft/min | | Accuracy | ± (3% + 1d) of reading or ±(1% + 1d) Full Scale | | (whichever is greater) | | MPH | | Range | 0.5 to 45.0 MPH | | Resolution | 0.1 MPH | | Accuracy | ± (3% + 1d) of reading or ±(1% + 1d) Full Scale | | (whichever is greater) | | knots | | Range | 1.0 to 31.0 knots | | Resolution | 0.1 knots | | Accuracy | ± (3% + 1d) of reading or ±(1% + 1d) Full Scale | | (whichever is greater) | | Temperature | | Range | 32 to 122°F (0 to 50°C) | | Resolution | 0.1°F and °C | | Accuracy | 1.5°F (0.8°C) |
 |

Extech Instruments 407730 - Digital Sound Level Meter
Features: - ±2dB accuracy with 0.1dB resolution
- A+C weighting
- AC analog output
- Record Max/Min values over time
- Utilizes 0.5"(12.7mm) electret condenser microphone
- 40 to 130dB measuring range
Specifications: | Display Counts | 2000 count LCD | | Range | 40 to 130dB | | Basic Accuracy | ±2dB | | Condenser Microphone | 0.5" (12.7mm) | | Analog Output | AC | | Dimensions | 9x2.2x1.7"(230x57x44mm) | | Weight | 5.6 oz (160g) |
 |

Extech Instruments 42270 - Temperature/Humidity Datalogger
Features: - Records Relative Humidity and Temperature in storage containers, shipping vans, freezers and more
- Logs data for days, weeks or months - up to 1 year battery life
- Multiple Dataloggers can be programmed and data downloaded from one single docking station.
- Programmable sampling rate from 1 second to 2 hours
- Program the logger, analyze and store data using Windows® 95/98/2000/NT/ME/XP compatible software
- View both humidity and temperature on LCD display
Specifications: | Display | Multi-function LCD | | Front panel status LEDs | Two (2) - RECORD and ALARM | | Temperature range | -40 to 185°F (-40 to 85°C) | | Temperature resolution | 0.1 / 1°F or C | | Temperature accuracy | ±1.2°F (0.6°C) from -4 to 122°C (-20 to 50°C) ±2.4°F (1.2°C) | | Humidity range | 0.0 to 100.0% Relative Humidity | | Humidity accuracy | ±3% | | Datalogger storage | 16,000 readings (8,000 each for temperature and humidity) | | Sampling rate | Programmable. 1 to 7200 seconds (2 hours) | | Power supply | One (1) CR2 or ½ ‘AA' lithium battery | | Battery Life | 1 year - 5 second sample rate in sleep mode, 3.8 months - 24 hour sample rate in non-sleep mode | | Low battery indicator | Display shows ‘LO' | | Cable length | 60'' (150cm) | | Operating Temperature | 32 to 104°F (0 to 40°C) | | Operating Humidity | 10 to 80% RH | | Dimensions | 4.9 x 3.6" (124 x 92mm) |
 |

Extech Instruments 42275 - Temperature/Humidity
Features: - Records Relative Humidity and Temperature in storage containers, shipping vans, freezers and more
- Logs data for days, weeks or months - up to 1 year battery life
- Multiple Dataloggers can be programmed and data downloaded from one single docking station
- Programmable sampling rate from 1 second to 2 hours
- Program the logger, analyze and store data using Windows 95/98/2000/NT/ME/XP compatible software
- View both humidity and temperature on LCD display
 |
Extech Instruments 42276 - Temperature/Humidity Datalogger Programmer with Printer
Features: - Self standing battery operated programming unit and printer - eliminates the need for a PC
- Datalogger module records Relative humidity and temperature in storage containers, shipping vans, freezers and more
- Datalogger transfers data to programmer
- Programming is performed through the 5 button control panel and integral LCD display
- Print numerical data or graphs on thermal paper
- Portable size is packaged in an ABS plastic case
Specifications: | Temperature Range | -40 to 185°F (-40 to 85°C) | | Temperature Resolution | 0.1°F/C | | Temperature Accuracy | ±°F (-4 to 122°F), ±2°F (-40 to -4°F and 122 to 185°F), ±0.6°C (-20 to 50°C), ±1.2°C (-40 to 20°C and 51 to 85°C) | | Humidity Range | 0 to 100% Relative Humidity | | Humidity Resolution | 0.1% RH | | Humidity Accuracy | ±5% | | Repeatability | ±1°C | | Datalogging interval | 1 second to 2 hours | | Memory | 16,000 reading storage in Datalogger Module(8,000 temperature + 8,000 RH readings) | | Power | Four (4) ‘AAA' 1.5V batteries (optional AC adapter) | | Power consumption | < 3.2A peak when printing < 300mA average when printing, 0.5 to 2mA (idle), 40 to 80uA (powered down) | | Auto power off | Device turns off automatically after 10 minutes to conserve battery energy | | Printer paper size | 57mm x 4M (length) | | Dimensions | 6.1 x 4.8 x 1.9 (155 x 122 x 48mm) | | Weight | 12 oz. (338g) |
 |

Extech Instruments $2500 - Small IR Thermometer
Features: - Built-in laser pointer identifies target area
- Backlighting illuminates display for taking measurements at night or in areas with low background light levels
- Automatic Data Hold when trigger released
- Fixed 0.95 emissivity covers 90% of surface applications
- Auto power off
Specifications: | Range / Resolution | -4 to 500°F (-20 to 260°C), 1°C/F | | Accuracy | ± 3% of reading or ± 6°F (3°C) whichever is greater. | | Note | Accuracy is specified for the following ambient temperature range: 64 to 82°F (18 to 28°C) | | Emissivity | 0.95 fixed value | | Field of View | D/S = Approx. 6:1 ratio (D = distance, S = spot) | | Laser power | Less than 1mW | | Spectral response | 6 to 14 µm (wavelength) | | General Specifications | | Display | 2000 count, backlit LCD display with function indicators | | Display rate | 1 second approx. | | Operating Temperature | 32°F to 122°F (0°C to 50°C) | | Operating Humidity | Max. 80% RH | | Power Supply | 9V battery | | Automatic Power Off | Meter shuts off automatically after 6 seconds | | Weight | 4.9 oz. / 140g | | Dimensions | 6.7 x 1.7 x 1.6" (170 x 44 x 40mm) |
 |

Extech Instruments 42510 - Small Wide Range IR Thermometer
Features: - Adjustable High/Low setpoints with audible alarm alerts user when temperature exceeds the programmed setpoints
- Built-in laser pointer identifies target area
- Backlighting illuminates display for taking measurements at night or in areas with low background light levels
- Adjustable emissivity for better accuracy on different surfaces
- Compact thermometer measures temperature from -58 to 1200°F (-50 to 650°C) with 0.1° resolution up to 199.9°
- 12:1 distance to target ratio
- Data Hold and Min/Max
- Overrange indicator
- Auto power off
- Complete with 9V battery and pouch case
Specifications: | Range / Resolution | -58 to 200°F (-50 to 200°C), 200°F to 1400°F (200°C to 760°C) | | Accuracy | ± 2% of reading or ± 4°F (2°C) whichever is greater. | | Note | Accuracy is specified for the following ambient temperature range: 64 to 82°F (18 to 28°C) | | Emissivity | 0.95 fixed value | | Field of View | D/S = Approx. 8:1 ratio (D = distance; S = spot) | | Laser power | Less than 1mW | | Spectral response | 6 to 14 µm (wavelength) | | General Specifications | | Display | Backlit LCD display with function indicators | | Display update rate | 1 second approx. | | Operating Temperature | 32°F to 122°F (0°C to 50°C) | | Operating Humidity | Max. 80% RH. | | Power Supply | 9V battery | | Automatic Power Off | Meter shuts off automatically after 6 seconds | | Weight | 6.4 oz. / 180g | | Dimensions | 3.2 x 1.6 x 6.3" (82 x 42 x 160mm) |
 |

Extech Instruments 42515 - IR Thermometer Plus Type K Input
Features: - Wide temperature range for IR temperature and type K thermocouple measurements
- Automatic emissivity adjustment (for temperatures 212°or higher)
- Memory stores up to 20 readings
- Large LCD display with bright backlight for easy-to-read measurements and programming parameters
- Laser pointer provides better aim and accuracy
- Auto-hold activates when the measurement trigger is released
- Adjustable high/low alarm alerts user visually and audibly when the temperature exceeds programmmed limits.
- MAX/MIN/AVG/DIF features display highest, lowest, average, and MAX minus MIN values
- Data Hold, Auto power off with disable function, low battery indication
- Switches built into handle allow for °C/°F display selection, auto power off defeat, and alarm on/off control
- Complete with 9V battery, type K thermocouple sensor (-4 to 482°F/-20 to 250°C), and carrying case
Specifications: | Display Counts | 4000 count backlit display | | Range | IR: -58°F to 1472°F or -50°C to 800°C Type K: -58°F to 2498°F or -50°C to 1370°C | | Basic Accuracy | IR: ±2% reading or ±4°F/2°C whichever is greater < 932°F/500°C ±(2.5%rdg+5°) > 932°F/500°C Type K: ±1.5% reading ±5°F/3°C | | Max. Resolution | 0.1°F/°C | | Emissivity | 0.10 to 1.00 Adjustable | | Field of View | 13:1 (Distance to target ratio) | | Dimensions | 3.2 x 1.6 x 6.3" (82 x 42 x 160mm) | | Weight | 6.4 oz (180g) |
 |
Extech Instruments 42529 - IR Thermometer
Features: Built-in laser pointer identifies target area Backlighting illuminates display for taking measurements at night or in areas with low background light levels Audible and visible overrange indicators Automatic Data Hold when trigger released Specifications: | Range / Resolution | 0 to 600°F (-20 to 320°C) 1°C/F | | Accuracy | ± 2% of reading or ± 4°F (2°C) whichever is greater. | | Note | Accuracy is specified for the following ambient temperature range: 64 to 82°F (18 to 28°C) | | Emissivity | 0.95 fixed value | | Field of View | D/S = Approx. 6:1 ratio (D = distance, S = spot) | | Laser power | Less than 1mW | | Spectral response | 6 to 14 µm (wavelength) | | General Specifications | | Display | 31/2 digit backlit LCD display with function indicators | | Display rate | 1 second approx. | | Over range indication | Audible tone sounds and ‘OVER' appears on the LCD when the measurement exceeds the measurement range spec. | | Operating Temperature | 32°F to 122°F (0°C to 50°C) | | Operating Humidity | Max. 80% RH. | | Power Supply | 9V battery | | Automatic Power Off | Meter shuts off automatically after 7 seconds | | Weight | 6.35 oz. / 180g | | Size | 8.3 x 3.5 x 1.5" (211 x 89 x 38mm) |
 |

Extech Instruments 42530 - Wide Range IR Thermometer
Features: - Built-in laser pointer identifies target area
- Backlighting illuminates display for taking measurements at night or in areas with low background light levels
- Audible and visible overrange indicators
- Automatic Data Hold when trigger released
Specifications: | Range / Resolution | -58 to 1000°F (-50 to 538°C) 0.1°C/F<200 / 1°C/F> 200 | | Accuracy | ± 2% of reading or ± 4°F (2°C) whichever is greater. | | Note | Accuracy is specified for the following ambient temperature range: 64 to 82°F (18 to 28°C) | | Emissivity | 0.95 fixed value | | Field of View | D/S = Approx. 8:1 ratio (D = distance, S = spot) | | Laser power | Less than 1mW | | Spectral response | 6 to 14 µm (wavelength) | | General Specifications | | Display | 3 1/2 digit backlit LCD display with function indicators | | Display rate | 1 second approx. | | Operating Temperature | 32°F to 122°F (0°C to 50°C) | | Operating Humidity | Max. 80% RH. | | Power Supply | 9V battery | | Automatic Power Off | Meter shuts off automatically after 7 seconds | | Weight | 6.35 oz. / 180g | | Size | 8.3 x 3.5 x 1.5" (211 x 89 x 38mm) |
 |

Extech Instruments 42540 - High Temp IR Thermometer
Features: - Widest temperature range from -58° to 1400°F (-50 to 760°C)
- Built-in laser pointer identifies target area
- High 12 to 1 distance to target ratio measures smaller surface areas at greater distances
- Backlighting illuminates display for taking measurements at night or in areas with low background light levels
- Automatic Data Hold
Specifications: | Range / Resolution | -58 to 1400°F (-50 to 760°C) 0.1°C/F | | Accuracy | ±(2% + 2°) at <932°F (500°C) ±(2.5% + 5°) at > 932°F (500°C) | | Note | Accuracy is specified for the following ambient temperature range: 64 to 82°F (18 to 28°C) | | Emissivity | 0.95 fixed value | | Field of View | D/S = Approx. 12:1 ratio (D = distance, S = spot) | | Laser power | Less than 1mW | | Spectral response | 6 to 14 µm (wavelength) | | General Specifications | | Display | 3 1/2 digit backlit LCD display with function indicators | | Display rate | 1 second approx. | | Operating Temperature | 32°F to 122°F (0°C to 50°C) | | Operating Humidity | Max. 80% RH. | | Power Supply | 9V battery | | Automatic Power Off | Meter shuts off automatically after 6 seconds | | Weight | 10.2 oz. / 290g | | Dimensions | 3.9 x 2.2 x 9.0" (100 x 56 x 230mm) |
 |

Extech Instruments 42542 - High Temp IR Thermometer
Features: - Automatic Data Hold when trigger released
- Adjustable high/low alarm alerts user visually and audibly when temperature exceeds programmed limits accuracy on different surfaces
- High Temperature range from -58° to 1832°F (-50 to 1000°C)
- Auto power off
- 30 to 1 distance to target ratio measures smaller surface areas at greater distances
- MIN/MAX/AVG/DIF features display highest, lowest, average, and MAX minus MIN values
- Large backlit display allows for taking measurements at night or in areas with low background light
- Laser pointer identifies target area
- High resolution of 0.1º up to 199.9º
- Complete with 9V battery and hard carrying case
Specifi | Range | -58 to 1832°F (-50 to 1000°C) | | Basic Accuracy | ±2% of rdg or 4°F/ 2°C whichever is greater <932°F (500°C); ±(2.5%rdg + 5°)>932°F (500°C) | | Max. Resolution | 0.1°F/°C | | Emissivity | 0.1 to 1.00 Adjustable | Field of View (Distance to Target) | 30:1 | | Dimensions | 3.9 x 2.2 x 9" (100 x 56 x 230mm) | | Weight | 10.2oz (290g) | cations:
 |

Extech Instruments 42545 - High Temp IR Thermometer
Features: - High and low alarm set points
- Built-in laser pointer identifies target area
- Backlighting illuminates display for taking measurements at night or in areas with low background light levels
- High resolution of 0.1° up to 199.9°
- Adjustable emissivity
- Wide temperature range from -58 to 1832°F (-50 to 1000°C)
Specifications: | Range / Resolution | -58 to 1832oF (-50 to 1000oC) | | Accuracy | -58 to -4°F : ±9°F -4 to 1000°F : ±(2% rdg ± 4oF) 1001 to 1832°F : ±(3% rdg ± 9oF) -50 to -20°C : ±5°C -20 to 538°C : ±(2% rdg ± 2oC) 539 to 1000°C : ±(3% rdg ± 5oC)
| | Emissivity | 0.95 fixed value | | Field of View | D/S = Approx. 50:1 ratio (D = distance, S = spot) | | Laser power | Less than 1mW | | Spectral response | 6 to 14 μm (wavelength) | | Over range indication | LCD will display "1" | | Display | 3½ digit backlit LCD display with function indicators | | Display rate | 1 second approx. | | Operating Temperature | 32°F to 122°F (0°C to 50°C) | | Operating Humidity | Max. 80% RH. | | Power Supply | 9V battery | | Automatic Power Off | Meter shuts off automatically after 6 seconds | | Weight/Dimensions | 10.2 oz. / 290g 3.9 x 2.2 x 9.0" (100 x 56 x 230mm) |
 |

Extech Instruments 445580 - Humidity Meter
Features: - Simultaneous display of Temperature (°C/°F) and Relative Humidity
- Max/Min and Data Hold
- Built-in self calibration utility allows for field calibrations using optional Relative Humidity calibration bottles
- Includes meter with pocket clip and 3V lithium battery
Specifications: | Relative Humidity Sensor | High Precision thin-film capacitance type | | Temperature Range | 14 to 122°F (-10 to 50°C) | | Relative Humidity Range | 10 to 90% Relative Humidity | | Resolution Temperature | 0.1°, Relative Humidity - 0.1% | | Accuracy Temperature | ±1.8°F (±1.0°C), Relative Humidity - ±5% | | DC Power | 2032 button battery (150 hour battery life) | | Response time | 120 seconds | | Dimensions | 6.9 x 1.6 x 0.6" (175 x 42 x 16mm) |
 |
Extech Instruments 445815 - Hygro-Thermometer with Dew Point
Features: - In summertime, identifies and warns when conditions for mold growth exist
- In wintertime, identifies and warns when low humidity conditions for static electricity exist
- Remote probe allows for measurements behind walls or in difficult to access locations
- Air temperature and dew point temperature indicate where condensation may occur
- Monitor conditions in laboratories, storage areas and other controlled environment settings
- Ideal solution when traceable ISO calibrations are required by operating standards
Specifications: - %RH audible and visual alarm alerts when humidity exceeds set limit
- Displays Dew Point temperature
- Rear calibration adjustment pot for Humidity and Temperature
- Probe clips onto meter or extends on 18" (457mm) cable
- Max/Min with reset function
- Humidity: 10 to 99%
- Temperature: 14 to 140°F (-10 to 60°C)
- Basic Accuracy: ±4%RH; ±1.8°F/1°C
- One year warranty
 |

Extech Instruments 451104 - Vane Thermo-Anemometer
Features: - Air velocity and temperature displayed on large multi-function LCD
- Up to 2-hour air velocity averaging for measurements
- Built-in rotary vane sensor for one hand operation
- Data hold and Auto power off Min/Max
- RS-232 interface for capturing data directly on a PC
Specifications: | Display | 4 digit LCD display (0 to 9999 display counts) | | Operating Temperature | 14°F to 122°F (-10°C to 50°C) | | Operating Humidity | 80% RH max. | | Meter Power | DC 9V; 100 hours continuous battery life (20 minute automatic power OFF conserves energy) | | Weight | 1.5 lb (680g) | | Dimensions | 7.2 x 3.0 x 1.8" (183 x 76 x 45 mm) | | Sensor Diameter | 3" (70mm) | | Accessories | 9V battery, hard carry case, and Instruction manual |
 |

Extech Instruments 451112 - Big Digit Thermo-Anemometer
Features: - High accuracy via low friction ball bearing vane wheel on 39" (1m) cable
- Utilizes a Type K sensor for temperature measurements
- Data hold
- Ideal when reaching into an air duct or other HVAC applications
Specifications: | Display | 0.7" (18mm) 3-1/2 digit (1999 count) LCD | | Measurement | m/s (meters per second), km/h (kilometers per hour), ft/min (feet per minute), knots (nautical miles per hour), Temp. °C/°F | | Data hold | Freezes present value on display when selected | | Sensor | Structure Air velocity sensor: Conventional twisted vane arm with balanced, low-friction ball-bearing design | | Temperature sensor | Thermister | | Ambient | 32°F to 122°F (0°C to 50°C); <80% | | Power Supply | 9V battery (Heavy duty type) | | Power Current | Approx. 9 mA DC | | Weight | 12 oz. (325 g) (including battery) | | Dimensions Main instrument | 6.6 x 3.2 x1.2" (180 x 72 x 32 mm) | | Sensor Head | Round, 2.8" (72 mm) Dia. | | Sensor Cable | 39" (1m) length | | m/s | | Range | 0.4 - 30.0 m/s | | Resolution | 0.1 m/s | | Accuracy | ± (2% + 0.2 m/s) | | km/h | | Range | 1.4 - 108.0 km/h | | Resolution | 0.1 km/h | | Accuracy | ± (2% + 0.2 km/hr) | | ft/min | | Range | 80 - 5910 ft/min | | Resolution | 10 ft/min | | Accuracy | ± (2% + 20 ft/min) | | knots | | Range | 0.8 - 58.3 knots | | Resolution | 0.1 knots | | Accuracy | ± (2% + 0.2 knots) | | Temp. | | Range | 0° to 60°C / 32° to 140°F | | Resolution | 0.1°C / 0.1°F | | Accuracy | 0.8°C / 1.5°F |
 |

Extech Instruments 451126 - CFM Vane Anemometer Datalogger
Features: Dual Display provides "Air velocity + Temperature" or "Air flow + Area" Measures air flow in CFM Internal 1000 point datalogger plus built-in RS-232 PC interface MAX/MIN/AVG readings Specifications: | Display | Dual 4-digit (9999 count) Multi-function LCD | | Data hold | Locks latest reading on the LCD display | | Sensor | Structure Air velocity sensor: Conventional twisted vane arm with low friction (sapphire) ball bearing. Temperature sensor: K-type thermocouple built into vane. 1/4" mounting nut provided. | | Memory Recall | Records Max/Min readings with push-key RECALL | | Data Output | RS-232 PC serial interface | | Operating conditions (Meter) | | Temperature | 32°F to 122°F (0°C to 50°C) | | Humidity | <80% RH; | | Pressure | 500mB to 2 Bar | | Operating conditions (Vane) | | Temperature | 32°F to 140°F (0°C to 60°C) | | Humidity | <80% RH; | | Pressure | 500mB to 2 Bar | | Storage Temperature | -40°F to 140°F (-40°C to 60°C) | | Power Supply | 9V battery; | | Battery life | 50 hours typical | | Power Consumption | Approx. 3 mA DC | | Weight | 0.77 lbs. (350g) | | Dimensions Meter | 3.46 x 6.61 x 1.03" (88 x 168 x 26.2mm) | | Vane | 2.6 x 5.22 x 1.15" (66 x 132 x 29.2mm) | | Accessories | 9V battery and carrying case | | Feet per Minute (ft/min) | | Calibrated Range | 60.0 to 8800 | | Display Resolution | 0.1 | | Accuracy | ± (3% + 20 ft/min) | | Meters per Second (m/s) | | Calibrated Range | 0.30 to 45.00 | | Display Resolution | 0.01 | | Accuracy | ± (3% + 0.1 m/s) | | Kilometers per Hour (km/hr) | | Calibrated Range | 1.00 to 140.0 | | Display Resolution | 0.01 | | Accuracy | ± (3% + 0.4 km/hr) | | Miles per Hour (mile/hr) | | Calibrated Range | 0.70 to 100.0 | | Display Resolution | 0.01 | | Accuracy | ± (3% + 0.2 mile/hr) | | Knots | | Calibrated Range | 0.60 - 88.0 | | Display Resolution | 0.01 | | Accuracy | ± (3% + 0.2 knots) | | CFM (ft³/min) | | Range | 0 to 999900 | | Resolution | 0.001 to 100 | | Area | 0.001 to 9999 | | CMM (m³/min) | | Range | 0 to 999900 | | Resolution | 0.001 to 100 | | Area | 0.001 to 9999 |
 |

Extech Instruments 45118 - Mini Thermo-Anemometer
Features: - Display Air Velocity and Temperature or Windchill
- Selectable averaging function of 5, 10, or 13 second intervals
- Fold up protective housing extends to 9" (229mm) for better reach
- Tripod mount
- Data Hold with Auto power off
Specifications: | Display | Dual LCD with multifunction indicators | | Measurements | Knots, km/h, MPH, ft/min, m/sec, Beaufort force, windchill, and temperature (C/F) | | Wind-speed | Moving 2 second average with 2 second gust detect | | Sensor | Sapphire bearing, non-corrosive vane for air velocity and precision thermistor for temperature | | Average Mode | Choice of 5, 10, or 13 second average readings | | Max Display | Push button highest reading recall | | Data hold | Freeze most recent display | | Sample time | 1 reading per second | | Water-resistant | To 3' (1 meter) | | Min/Max wind-speed | 1.1 to 62.5 MPH | | Operating temperature | 5° to 122°F (-15° to 50°C) | | Operating humidity | < 80% RH | | Power supply | Lithium battery type CR-2032 or equivalent | | Battery life | 400 hours approx. | | Weight | 3 oz. ( 95 g ) | | Dimensions Instrument | 5.25 x 2.75 x 0.75" (133 x 70 x 19mm) | | Vane | 1" ( 24mm ) diameter | | MPH (Miles per hour) | | Range | 1.1 to 62.5 MPH | | Resolution | 0.2 MPH | | Accuracy | ± (3%rdg +0.4MPH) | | km/hr (kilometers per hour) | | Range | 1.8 to 100.6 km/h | | Resolution | 0.7 km/h | | Accuracy | ± (3%rdg +1.4km/h) | | Knots (nautical miles per hour) | | Range | 1.0 to 54.3 knots | | Resolution | 0.3 knots | | Accuracy | ± (3%rdg +0.6knots) | | m/sec (meters per second) | | Range | 0.50 to 28.00 m/s | | Resolution | 0.01 m/s | | Accuracy | ± (3%rdg +0.2m/s) | | ft/min (feet per minute) | | Range | 100 to 5500 ft/min | | Resolution | 20ft/min | | Accuracy | ± (3%rdg +40ft/min) | | Beaufort force | | Range | 1 to 17 BF | | Resolution | 1 BF | | Accuracy | ± 1 |
 |

Extech Instruments 451181 - Datalogging/Printing
Features: - Simultaneously measures and displays Air Velocity, Temperature, Humidity, Wet Bulb, plus calculates CFM/CMM
- Manually logs 99 readings or setup time intervals for automatic logging (2400 points)
- Datalogger date/time stamps and stores data for later recall, printing or downloading to a PC
- Thermal printer prints air velocity, temperature, humidity, wet bulb, and CFM data with date and time stamp
- Backlit display for operating in dimly lit areas
- Auto Power Off
- RS-232 PC interface with Windows® 95/98/NT/2000/ME/XP compatible software to analyze data on PC
- Complete with vane sensor with 4ft (120cm) cable, software and cable, 4 AA batteries, one paper roll, and carrying case
Specifications: | Display | Backlit Multi-function LCD | | Datalogger memory | 2400 readings in Auto mode (99 readings in Manual mode) | | Over range indication | "-------" appears on the LCD | | Printer | 38mm printer includes Data/Time Stamp with each reading | | PC Interface | RS-232C (TTL level) | | PC Software | Windows 95/98/NT/2000/ME/XP software included | | Low battery indication | Battery symbol appears on the LCD | | Power supply | Four (4) 1.5V ?AA? batteries or optional 6V (1000mA) adapter | | Operating current | 500mA (printing) | | Auto Power OFF | Adjustable form 1 to 20 minutes | | Operating Temperature | 32 to 122oF (0 to 50oC) | | Operating Humidity | 90% Relative Humidity maximum | | Dimensions/Weight | 8.1 x 2.75 x 2.0? (208 x 70 x 53mm) / 9.2 oz. (260g) w/battery |
 |

Extech Instruments 45158 - Mini Thermo-Anemometer + Humidity
Features: - Display air velocity and either Relative Humidity, Dew Point, Temperature or Windchill
- Selectable averaging function of
- 5, 10, or 13 second intervals
- Fold up protective housing extends to 9" (229mm) for better reach, Tripod mount
- Data Hold with Auto power off
- Water resistant housing floats
Specifications: | Range | 1.1 to 62.5 MPH | | Resolution | 0.2 MPH | | Accuracy | ± (3% + 0.4 mph) | | km/hr (kilometers per hour) | | Range | 1.8 to 100.6 km/h | | Resolution | 0.7 km/h | | Accuracy | ± (3% + 1.4 km/hr) | | Knots (nautical miles per hour) | | Range | 1.0 to 54.3 knots | | Resolution | 0.3 knots | | Accuracy | ± (3% + 0.6 knots) | | m/sec (meters per second) | | Range | 0.50 to 28.00 m/s | | Resolution | 0.01 m/s | | Accuracy | ± (3% + 0.2 m/s) | | ft/min (feet per minute) | | Range | 100 to 5500 ft/min | | Resolution | 20ft/min | | Accuracy | ± (3% + 40 ft/min) | | Beaufort force | | Range | 1 to 17 BF | | Resolution | 1 BF | | Accuracy | ± 1 | | Temperature | | Range | 0° to 122°F (-18° to 50°C) | | Resolution | 0.1°F/C | | Accuracy | ± 1.8°F (± 1°C) | | Relative Humidity | | Range | 10 to 95% | | Resolution | 1% | | Accuracy | ± 5% RH | | Dew Point | | Range | 32° to 122°F (0° to 50°C) | | Resolution | 0.1°:F/C | | Accuracy | ± 3.6°F (2°C) | | General Specifications | | Display | Dual LCD with low battery and multifunction indicators | | Sensors | Sapphire bearing, non-corrosive vane for air velocity; Precision thermistor for temperature measurements | | Average Mode | Choice of 5 or 10 reading averaging (2 second factory default) | | Max and Data Hold Displays | Max recalls the highest reading; Data Hold freezes the display | | Sample time | 1 reading per second for air velocity and temperature (1 reading per 15 seconds for humidity with 2 second updates) | | Water-resistant | To 3' (1m) | | Operating conditions | 5° to 122°F (-15° to 50°C) / < 80% RH | | Power supply | Lithium battery (CR-2032 or equivalent) / 400 hour battery life) | | Dimensions / Weight Instrument | 5.25 x 2.75 x 0.75" (133 x 70 x 19mm) | | Vane | 1" ( 24mm ) diameter / 3 oz. ( 95 g ) |
 |

Extech Instruments 45160 - 3-in-1 Humidity Temperature and Airflow Meter
Features: - Simultaneously displays Temperature and Air Velocity or Relative Humidity
- Type K input socket for high temperature measurements to 2372°F (1300°C) using optional (TP870) Type K thermocouple
- Min/Max, Data hold, Auto power off with disable feature
- Built-in low friction vane wheel improves air velocity accuracy
- Thin-film capacitance humidity sensor for fast response
Specifications: | Range | 0.9 to 67.0 MPH | | Resolution | 0.1MPH | | Accuracy | ≤3937 ft/min: ±3% F.S., > 3937 ft/min: ±4% F.S | | km/hr (kilometers per hour) | | Range | 1.4 to 108.0 km/h | | Resolution | 0.1km/h | | Accuracy | ≤3937 ft/min: ±3% F.S., > 3937 ft/min: ±4% F.S | | Knots (nautical miles per hour) | | Range | 0.8 to 58.3 knots | | Resolution | 0.1knots | | Accuracy | ≤3937 ft/min: ±3% F.S., > 3937 ft/min: ±4% F.S | | m/sec (meters per second) | | Range | 0.40 to 30.00 m/s | | Resolution | 0.01 m/s | | Accuracy | ≤3937 ft/min: ±3% F.S., > 3937 ft/min: ±4% F.S | | ft/min (feet per minute) | | Rnage | 80 to 5910 ft/min | | Resolution | 10ft/min | | Accuracy | ≤3937 ft/min: ±3% F.S., > 3937 ft/min: ±4% F.S | | Temperature/Thermistor | | Range | 32° to 122°F (-0° to 50°C) | | Resolution | 0.1°F/C | | Accuracy | ± 2.5°F (± 1.2°C) | | Temperature /Thermocouple | | Range | -148° to 2372°F, -100° to 1300°C | | Resolution | 0.1°F, 0.1°C | | Accuracy | ± (1% + 2°F), ± (1% + 1°C) | | Relative Humidity | | Range | 10.0 to 95.0% | | Resolution | 0.1% ±4% RH (from 10% to 70%RH) | | Accuracy | ±5.2% RH (> 70% RH) | | General Specifications | | Display | 4 digit (9999 count) Dual Display LCD | | Sensors | Thin film capacitance humidity sensor | | Min/Max Min/Max | recalls the highest/lowest reading | | Data Hold | Data Hold freezes the display | | Operating conditions | 32° to 122°F (0° to 50°C) / < 80% RH | | Power supply | 9 Volt Battery | | Dimensions / Weight Instrument | 6.14 x 2.36 x 1.29" (156 x 60 x 33mm) | | Vane | 1" ( 24mm ) diameter / 3 oz. ( 95 g ) |
 |

Extech Instruments AN200 - CFM/CMM Thermo-Anemometer & IR Thermometer
Features: - CFM/CMM Thermo- Anemometer with built-in non-contact IR Thermometer measures remote surface temperatures to 536°F (280°C) with 8:1 distance to spot ratio and Laser Pointer
- Simultaneous display of Ambient Temperature and Air Flow or Air Velocity
- Up to 8 easy to set Area Dimensions are stored in the meter's internal memory
- 20 point average function for Air Flow
- Super large LCD Backlit Display
- 3% velocity accuracy via low friction 2.83" D (72mm) ball bearing vane wheel on 3.9 ft. (120cm) cable
- Data hold and MIN/MAX
- Auto Power off
- Completer with vane sensor with 3.9 ft. (120cm) cable, 9V battery, protective rubber holster, and carrying case
Specifications: | General Specifications | Range | Resolution | Basic Accuracy | | Air Velocity | 0.40 to 30.00 m/s 1.4 to 108.0 km/h 80 to 5906 ft/min 0.9 to 67.2 mph 0.8 to 58.3 knots | 0.01 m/s 0.1 km/h 1 ft/min 0.1 mph 0.1 knots | ±3% m/s ±3% km/h ±3% ft/min ±3% mph ±3% knots | | Air Temperature | 14 to 140°F (-10 to 60°C) | 0.1°F/°C | ±6.0°F (3°C) | InfraRed Temperature (AN200 Only) | -58 to -4°F (-50 to -20°C) -4 to 500°F (-20 to 260°C) | 0.1°F/°C 1°F/°C | ±9.0°F (5.0°C) ±2% reading or ±2°F (°C) whichever is greater | | Air Flow | 0 to 9999 CMM (M³/min) 0 to 9999 CFM (ft³/min) | 0.1 0.1 | |
 |

Extech Instruments AN400 - Cup Thermo-Anemometer
Features: - Rotating cups provide accurate air velocity measurements
- Wide range air velocity measures m/s, ft/min, km/hr, and knots
- Dual LCD digital display of Air Velocity and Temperature
- Record Max and Min values
- Datalogger stores up to 100 readings
- Water resistant housing
- Complete with four AAA batteries
 |

Extech Instruments EA15 - Thermocouple Datalogging Thermometer
Features: - Dual input accepts Types J, K, E, T, R, S, and N thermocouples
- Built-in datalogger stores up to 8800 data sets
- RS-232 port to transfer data to PC for analysis
- Real Time Clock
- Includes Windows® 95/98/NT/2000/ME/XP compatible software and cable
- Compact and rugged design features large backlit display
- Displays [T1 plus T2] or [T1-T2 plus T1] or [T1-T2 plus T2]
- Selectable units of °F, °C, K (Kelvin)
- Wide temperature range with 0.1°/1° resolution
- Timer function displays elapsed time plus the time when MIN and MAX readings are taken
- OFFSET key used for zero function to make relative measurements
- Data Hold function freezes reading on display
- Auto Power off to save battery life
- Low battery and overrange indication
- Records Max/Min readings for later recall
- Complete with built-in stand, protective holster, two Type K bead wire temperature probes (-4 to 482°F/-20 to 250°C), and 6 AAA batteries
Specifications: | Measurement Ranges | | K - Type | -200.0°F to +1999.9°F (-150.0°C to +1370.0°C) | | J - Type | -200.0°F to +1994.0°F (-150.0°C to +1090.0°C) | | T - Type | -200.0°F to +752.0°F (-150.0°C to +400.0°C) | | E - Type | -200.0°F to +1598.0°F (-150.0°C to +870.0°C) | | R - Type | +32°F to +1999.9°F (0.0°C to +1767.0°C) | | S - Type | +32°F to +1999.9°F (0.0°C to +1767.0°C) | | N - Type | -200.0°F to +1999.9°F (-150.0°C to +1300.0°C) | | Resolution | | J, K, T, E, N - Type | 0.1°F/°C/K | | R, S - Type | 1.0°F/°C/K (0.1° for reference only) | | Accuracy | | J, K, T, E, N - Type | ±(0.05% reading + 1.5°F(0.75°C)) below -148°F (-100°C) | | J, K, E, N - Type | add ±0.15% | | T - Type | add ±0.45% | | R, S - Type | add ±(0.05 of reading +2°F(1°C)) | | Temperature Coefficient | Outside the specified range +64°F to 82°F (+18°C to 28°C) | ±(0.01% of reading +0.06°F per °F (+0.03 °C)) | | Below -148°F (-100°C) | | J, K, E, N - Type | 0.04% of reading | | T - Type | 0.08% of reading | | General | | Display | Dual Display Multi-function LCD with Backlight | | Input Protection | 60VDC, 24VAC rms | | Measurement Rate | 1 time per 1.5 second | | Over range indication | "OL" appears on the LCD | | Open input indication | "OL" appears on the LCD | | Low battery indication | "BT" appears on the LCD | | Manual Memory Capacity | 98 sets | | Datalogging Memory Capacity | 8800 sets | | Power supply | 6 ‘AAA' Batteries | | Battery life | Approximately 200 hours with alkaline batteries | | Operating Temperature | 32 to 122°F (0 to 50°C) | | Operating Humidity | < 80% RH | | Storage Temperature | 14 to 140°F (-10 to 60°C) | | Storage Humidity | 10 to 80% RH | | Dimensions | 5.91 x 2.8 x 1.4" (150 x 72 x 35mm) | | Weight Approx. | 8.29 oz. (235g) with batteries |
 |

Extech Instruments EA30 - Easyview Wide Range Light Meter
Features: - Compact and rugged design with large display
- Widest range to 40,000Fc/ 400,000Lux is ideal for outdoor applications
- Additional features: Large display with bargraph, Relative function for zero or difference from reference value and Peak captures short light pulses to 100μSeconds
- Data Hold and Min/Max readings
- Auto power off, Zero function
Specifications: | Display | Multi-function 3-3/4 (3999) digit LCD with Bargraph indicator | | Over range indication | LCD displays ‘OL' | | Spectral response | CIE photopic (CIE human eye response curve) | | Spectral accuracy | CIE V 2 function (f1 2 6%) | | Measurement Repeatability | ±2% | | Temperature coefficient | ±0.1% per °C | | Sampling rate | 13.3 times per second (bargraph); 1.3 times per second (digital display) | | Photo detector | Silicon photo-diode with spectral response filter | | Peak hold | Capture light peaks to 100uS | | Operating conditions Temperature | 32 to 104°F (0 to 40°C) | | Humidity | < 80% RH | | Storage conditions Temperature | 14 to 140°F (-10 to 50°C) | | Humidity | < 80% RH | | Dimensions | 5.91 x 2.8 x 1.4" (150 x 72 x 33mm) | | Weight | Approx. 11.3 oz. (320g) with battery | | Low battery indication | "BT" appears on the LCD | | Power supply | 6 ‘AAA' cells; Battery life approx 400 hours |
 |

Extech Instruments EA31 - Easyview Light Meter
Features: - Compact and rugged design with large display
- Low range model measures to 2,000Fc/ 20,000Lux
- Data Hold and Min/Max readings
- Auto power off, Zero function
Specifications: | Display | 3-1/2 digit, 2000 count LCD | | Over range indication | LCD displays ‘OL' | | Spectral response | CIE photopic (CIE human eye response curve), Cosine corrected | | Spectral accuracy | CIE V 2 function (f'1 6%) | | Measurement Repeatability | ±2% | | Calibration | Calibrated to a standard incandescent lamp at color temperature 2856°K | | Temperature coefficient | ±0.1% per °C | | Sampling rate | 2.5 times per second | | Photo detector | Silicon photo-diode and spectral response filter | | Operating conditions Temperature | 32 to 104 °F (0 to 40 °C) | | Humidity | <80% RH | | Storage conditions Temperature | 14 to 140 °F (-10 to 50 °C) | | Humidity | < 80% RH | | Dimensions | 5.91 x 2.8 x 1.4" (150 x 72 x 35mm) | | Weight Approx. | 11.3 oz. (320g) with battery | | Photo Detector Dimensions | 3.62 x 2.36 x 1.14" (92 x 60 x 29mm) | | Detector cable length | 3' (91cm) approximately | | Low battery indication | "BT" appears on the LCD | | Power supply | 6 ‘AAA' cells; Battery life approx 400 hours |
 |

Extech Instruments EA33 - Easyview Light Meter with Memory
Features: - Wide measurement range to 99,990Fc (999,900Lux) with resolution of 0.001Fc and 0.01Lux
- Luminous intensity (candela) calculations
- Store and recall up to 50 measurements, includes relative or real time clock stamp
- Ripple function excludes the effect of stray light from the primary light source measurement
- Auto Power off with disable feature
- Multiple point average function
- Timed-Hold, Relative in absolute value or % deviation, and Comparator function with high low alarms
- Cosine and color corrected, CNS 5119 Class II
- Complete with built-in stand, light sensor and protective cover with 36" (0.9m) cable, protective holster, 6 AAA batteries, and carrying case
Specifications: | Display Counts | 999,999 count LCD | | Fc Range | 9.999Fc, 99.99Fc, 999.9Fc, 9,999Fc, 99,990Fc | | Lux Range | 99.99Lux, 999.9Lux, 9999Lux, 99,990Lux, 999,900Lux | | Max. Resolution | 0.001Fc/0.01Lux | | Basic Accuracy | ±3% | | Cosine & Color Corrected | Yes | | Dimensions | 5.9x2.8x1.4" (150x72x33mm) | | Weight | 11.29oz (320g) |
 |

Extech Instruments EA80 - Indoor Air Quality Meter/Datalogger
Features: Checks for Carbon Dioxcide (CO2) concentrations Maintenance free dual wavelength NDIR (non-dispersive infrared) CO2 sensor Measurement ranges: CO2: 0 to 6,000ppm Temperature: -4 to 140°F (-20 to 60°C) Humidity: 10 to 95%RH Continuous (20,000 sets) or manual (99 sets) datalogging Data hold, Max/Min with Time stamp, and Alarm Auto Power off Easy calibration in fresh air Complete with (6) AAA batteries, RS232 cable, and Windows® 95/98/NT/2000/ME/XP compatible software Specifications: | CO2 | 0 to 6,000ppm | | Resolution | 1ppm | | Temperature | -4 to 140°F (-20 to 60°C) | | Resolution | 0.1°F/°C | | Humidity | 10 to 95% | | Resolution | 1% | | Datalogging | Continuous: 20,000 sets/Manual 99 sets | | Dimensions | 5.3 x 2.8 x 1.2" (135 x 72 x 31mm) | | Weight | 8.2 oz (235g) |
 |
Extech Instruments EZ20 - Flex IR Thermometer
Features: Non-contact temperature measurement from -58 to 1100°F (-50 to 600°C) 16" (406mm) flexible probe provides easy access for difficult to reach locations Large LCD display with backlighting Built-in laser pointer to improve aim °F/°C switchable Fixed emissivity (0.95) covers 90% of curface applications 8:1 distance to spot ratio Automatic Data Hold and auto power off Complete with 9V battery and carrying case Specifications: | Range | -58°F to 1100°F or -50°C to 600°C | | Accuracy | ±2% of reading or ±4°F/2°C (whichever is greater) | | Resolution | 0.1° up to 200° | | Emissivity | 0.95 fixed | | Display | Backlit LCD | | Field of View | 8.1 | | Dimensions | 6.42 x 1.77 x 1.34" (163 x 45 x 34mm) | | Weight | 9.28 oz (263g) |
 |

Extech Instruments EZ30 - EzFlex Thermo-Anemometer
Features: - Remote vane extends on 16" (406mm) gooseneck for easy access into hard to reach places
- Selectable air velocity units of ft/min, m/s, km/hr, mph, and knots
- Ideal when reaching into air duct or other HVAC applications
- 3% basic accuracy
- Type K sensor for temperature measurements
- Large easy to read 2000 count LCD display
- Data hold function allows user to freeze the displayed value
- Max hold retains highest reading in the display
- Auto power off and low battery indication
- Complete with battery and hard carrying case
 |

Extech Instruments HD200 - Differential Thermometer Datalogger & IR Thermometer
Features: - Datalogs up to 18,000 readings on each channel
- Display [T1, T2, T3(IR)] or [T1-T2] or [T1-T3] or [T2-T3]
- Differential T1-T2 display for HVAC/Superheat measurements
- Heavy Duty rugged double molded housing
- MAX/MIN/AVG and Data Hold
- Use IR Thermometer probe to measure non-contact surface Temperature up to 1022°F (550°C); 8:1 distance to spot ratio and Laser pointer
- User selectable 1°/0.1° resolution
- Triple LCD display (when IR probe is plugged in)
- USB port includes software
- Includes two Type K bead wire temperature probes (-4 to 482°F/-20 to 250°C), IR Thermometer probe, Windows® compatible software with USB cable, hard carrying case, and 9V battery
Specifications: | Specifications | Range Basic Accuracy | Basic Accuracy | | Temperature (Type K) | -328 to 2501ºF (-200 to 1372ºC) | ±0.15% | | Temperature (IR) | -22 to 1022ºF (-30 to 550ºC) | ±2% | | Resolution | 0.1°/1° | | Distance to Spot ratio | 8:1 | | Datalogging | 18,000 readings (continuous) | | Dimensions | 7.9 x 2.9 x 1.9" (201 x 75 x 50mm) | | Weight | 9.8oz (280g) |
 |

Extech Instruments HD300 - Thermo-Anemometer w/ IR Temperature
Features: - InfraRed Thermometer measures remote surface temperatures to 932°F (500°C) with 30:1 distance to spot ratio and Laser pointer
- Simultaneous display of Air Flow in CFM/CMM or Air Velocity plus Ambient Temperature
- Easy to set Area dimensions are stored in the meters internal memory for the next power on
- Large (9999 count) LCD backlit display
- 20 point average for air flow
- USB port includes software
- Includes Windows® compatible software with cable, vane sensor with 3.9ft (120cm) cable, hard carrying case, and 9V battery
Specifications: | Specifications | Range | Accuracy | | IR Temperature (non-contact) | -58 to 932ºF (-50 to 500ºC) | ±2% | | ft/min | 80 to 5900 ft/min | ±3% | | m/s | 0.4 to 30.00 m/s | ±3% | | km/h | 1.4 to 108.0 km/h | ±3% | | MPH | 0.9 to 67.0 MPH | ±3% | | knots | 0.8 to 58.0 knots | ±3% | | Temperature | 14 to 140ºF (-10 to 60ºC) | ±4ºF (2ºC) | | CFM/CMM | 0 to 999900 | | Dimensions | 8x3x1.9" (203x75x50mm) | | Weight | 9.8oz (280g) |
 |
Extech Instruments HD400 - Heavy Duty Light Meter
Features: - Large backlit LCD display with 40-segment bar graph
- Wide range to 4,000Fc or 40,000 Lux
- Cosine and color corrected measurements
- Utilizes precision silicon photo diode and spectral response filter
- Peak mode (10µS) captures highest reading
- Relative mode indicates change in light levels
- Min/Max and Data Hold
- Backlight for readings in low light levels
- Heavy Duty rugged double molded housing
- Built-in USB port
Specifications: | Fc Range | 40, 400, 4000Fc | | Lux Range | 400, 4000, 40kLux | | Accuracy | ±5% rdg | | Max Resolution | 0.01Fc/0.1Lux | | PC interface | USB | | Dimensions | 6.7 x 3.1 x 1.6" (170 x 80 x 40mm) | | Weight | 13.7oz (390g) |
 |

Extech Instruments HD450 - Heavy Duty Datalogging Light Meter
Features: - Large backlit LCD display with 40-segment bar graph
- records in a continuous mode up to 16,000 readings and can manually store/recall up to 99 selected readings
- Wide range to 4,000Fc or 40,000 Lux
- Cosine and color corrected measurements
- Utilizes precision silicon photo diode and spectral response filter
- Peak mode (10µS) captures highest reading
- Relative mode indicates change in light levels
- Min/Max and Data Hold
- Backlight for readings in low light levels
- Heavy Duty rugged double molded housing
- Built-in USB port
Specifications: | Fc Range | 40, 400, 4000Fc | | Lux Range | 400, 4000, 40kLux | | Accuracy | ±5% rdg | | Max Resolution | 0.01Fc/0.1Lux | | Datalogging | 16,000 continuous readings; 99 selected readings | | PC interface | USB | | Dimensions | 6.7 x 3.1 x 1.6" (170 x 80 x 40mm) | | Weight | 13.7oz (390g) |
 |

Extech Instruments IR100 - Mini IR Thermometer
Features: - Wide temperature range from -31 to 446°F (-35 to 230°C)
- Economical mini size design for convenience
- Automatic Data Hold when measure button is released
- Max Hold or Min Hold
- Lock feature for continuous scanning
- Fixed emissivity covers 90% of surface applications
- Auto power off
- Complete with CR2032 3V battery
Specifications: | Range | -31°F to 446°F or -35°C to 230°C | | Basic Accuracy | ±(2.0%rdg) or ±4°F/±2°C | | Max. Resolution | 0.1°F/°C | | Emissivity | 0.95 fixed | | Field of View | 1:1 (Distance to target ratio) | | Dimensions | 3 x 1.6 x 0.7" (75 x 40 x 18mm) | | Weight | 1.5 oz (43g) |
 |

Extech Instruments IR201 - IR Thermometer
Features: Wide temperature range from -58°F to 518°F without contact Built-in laser pointer to improve aim °F/°C switchable Fixed emissivity (0.95) covers 90% of surface applications 6:1 field of view Visual overrange indicator Data Hold and Max Hold | | | | |