 |
Extech Instruments Multimeters
|

Extech Instruments 38073 -Analog Multimeter
Easy to read analog display Measure AC/DC Voltage, DC Current, Resistance and Decibel 5% full scale accuracy Battery test on 9V and 1.5V batteries
 |

Extech Instruments Extech 380900 -Dual Channel, Datalogging, True RMS MultiMeter
Features: + 60,000 counts, dual input channels with dual display and 30 segment bargraph + 0.03% basic DCV accuracy + 200kHz AC bandwidth + Auto/manual ranging + Functions include Capacitance, Frequency, + Resistance, Continuity, Duty Cycle (TTL & + Sine Wave) and Diode test + AC/DC Current to 10A with 0.01¦ÌA resolution + Simultaneously displays Frequency and Duty Cycle + Stand-alone datalogging of 10,708 data points on both channels + Record data of both channels using a PC through the built-in RS-232 interface + Relative, Min/Max, and Hold functions + Overload and low battery indication Complete with test leads, protective holster with built-in stand, Windows 95/98/NT/2000/ME/XP compatible software, optically isolated RS-232 cable, and 9V battery
 |

Extech Instruments 381676 - Pen DMM with Non-Contact Voltage Detector
Features: Autoranging multimeter with rotary dial - Large 2000 count high contrast LCD display
- Non-Contact Voltage detection with visible and audible alarm
- Auto Power off, Data Hold, and Range Hold
- Functions include AC/DC Voltage, Resistance, Continuity and Diode Test
- Complete with test lead with alligator clips, two 1.5V AAA batteries, and carrying case
Specifications: | Specifications | Range | Resolution | Basic Accuracy | | Non-Contact Voltage | 100 to 600VAC | | | DC Voltage | 200mV, 2, 20, 200, 600V | 0.1mV | ±0.7% | | AC Voltage | 200mV, 2, 20, 200, 600V | 0.1mV | ±0.8% | | Resistance | 200, 2k, 20k, 200k, 2M, 20MΩ | 0.1½ | ±0.8% | | Diode Test | 1mA @ 1.5V approx | | | Continuity Test | Audible beep <50 ohms | | | Dimensions | 8.2x1.5x1.1" (208x38x29mm) | | | Weight | 3.9oz (110g) | |
 |

Extech Instruments EX310 - Mini Digital MultiMeters + Voltage Detector
Features: 0.5% basic accuracy 100 - 600VAC Non-contact voltage measurement Auto Power Off conserves battery life Low battery indicator Manual Ranging Specifications: | Display counts | 2000 | | Basic Accuracy | 0.5% | | NC Voltage Detector | 100 to 600VAC | | DC Voltage | 0.1mV to 600V | | AC Voltage | 1mV to 600V | | DC/AC Current | 0.1mA to 10A | | Resistance | 0.1Ω to 2000kΩ | | Capacitance | NA | | Frequency | NA | | Temperature (Type K) | NA | | Duty Cycle | NA | | Diode/Continuity | Yes | | Dimensions | 5.7x2.9x1.6" (147x76X42mm) | | Weight | 9oz (260g) |
 |

Extech Instruments EX320 - Mini Digital MultiMeters + Voltage Detector
Features: 0.5% basic accuracy 100 - 600VAC Non-contact voltage measurement Auto Power Off conserves battery life Low battery indicator Autoranging 2000 count Specifications: | Display counts | 2000 | | Basic Accuracy | 0.5% | | NC Voltage Detector | 100 to 600VAC | | DC Voltage | 0.1mV to 1000V | | AC Voltage | 0.1mV to 750V | | DC/AC Current | 0.1mA to 10A | | Resistance | 0.1Ω to 20MΩ | | Capacitance | NA | | Frequency | NA | | Temperature (Type K) | NA | | Duty Cycle | NA | | Diode/Continuity | Yes | | Dimensions | 5.7x2.9x1.6" (147x76X42mm) |
 |

Extech Instruments EX330 - Mini Digital MultiMeters + Voltage Detector
Features: 0.5% basic accuracy 100 - 600VAC Non-contact voltage measurement Auto Power Off conserves battery life Low battery indicator Autoranging 4000 count Data Hold Type K Temperature °F/ °C switchable Capacitance Frequency Duty Cycle Relative function Specifications: | Display counts | 4000 | | Basic Accuracy | 0.5% | | NC Voltage Detector | 100 to 600VAC | | DC Voltage | 0.1mV to 1000V | | AC Voltage | 0.1mV to 750V | | DC/AC Current | 0.1mA to 10A | | Resistance | 0.1Ω to 40MΩ | | Capacitance | 0.001nF to 200μF | | Frequency | 0.001Hz to 10MHz | | Temperature (Type K) | -58 to 1832°F (-50 to 1000°C) | | Duty Cycle | 0.1 to 99.9% | | Diode/Continuity | Yes | | Dimensions | 5.7x2.9x1.6" (147x76X42mm) | | Weight | 9oz (260g) |
 |

Extech Instruments EX410 - Manual Ranging MultiMeter
Features: Easy to read large backlit display Type K thermometer built-in for surface or air temperature measurements Input fuse protection and mis-connection warnings with audible and visible signals Data hold freezes display reading Ergonomically designed to fit comfortably in your hand Specifications: | Input Protection Limits | | VAC | 600V DC/AC | | V | DC or V AC 600V DC/AC, 200Vrms on 200mV range | | mA | DC 200mA 250V fast acting fuse | | A | DC 20A 250V fast acting fuse(30 seconds max every 15 minutes) | | Ohms, Continuity | 250Vrms for 15sec max | | General | | Diode Test | Test current of 1mA maximum, open circuit voltage 2.8V DC typical | | Continuity Check | Audible signal will sound if the resistance is less than approximately 150 Ω | | Input Impedance | 10M Ω | | AC Response | Average responding | | ACV Bandwidth | 50Hz to 1kHz | | DCA voltage drop | 200mV | | Display | 3 1/2 digit, 2000 count LCD, 0.9" digits | | Auto-Power Off | 15 minutes (approximately) | | Overrange indication | "1" is displayed | | Polarity | Automatic (no indication for positive polarity), Minus (-) sign for negative polarity. | | Measurement Rate | 2 times per second, nominal | | Low Battery Indication | " " is displayed if battery voltage drops below operating voltage | | Battery | One 9 volt (NEDA 1604) battery | | Fuses | mA, µA ranges, 0.2A/250V fast blow A range, 20A/250V ceramic fast blow | | Operating Temperature | 41°F to 104°F (5°C to 40°C) | | Storage Temperature | -4°F to 140°F (-20°C to 60°C) | | Operating Humidity | Max 80% up to 87vF (31°C) decreasing linearly to 50% at 104°F(40°C) | | Storage Humidity | <80% | | Operating Altitude | 7000ft. (2000meters) maximum. | | Weight | 0.753lb (342g) (includes holster). | | Size | 7.36" x 3.2" x 2.0" (187 x 81 x 50mm) (includes holster) | | Safety | For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (1995), EN61010-1 (1995) Overvoltage Category III, Pollution Degree 2. |
 |

Extech Instruments EX411 Manual Ranging MultiMeter
Features: Easy to read large backlit display True RMS AC measurements Type K thermometer built-in for surface or air temperature measurements Input fuse protection and mis-connection warnings with audible and visible signals Data hold freezes display reading Ergonomically designed to fit comfortably in your hand Specifications: | Input Protection Limits | | VAC | 600V DC/AC | | V | DC or V AC 600V DC/AC, 200Vrms on 200mV range | | mA | DC 200mA 250V fast acting fuse | | A | DC 20A 250V fast acting fuse(30 seconds max every 15 minutes) | | Ohms, Continuity | 250Vrms for 15sec max | | General | | Diode Test | Test current of 1mA maximum, open circuit voltage 2.8V DC typical | | Continuity Check | Audible signal will sound if the resistance is less than approximately 150 Ω | | Input Impedance | 10M Ω | | AC Response | True rms | | ACV Bandwidth | 50Hz to 1kHz | | DCA voltage drop | 200mV | | Display | 3 1/2 digit, 2000 count LCD, 0.9" digits | | Auto-Power Off | 15 minutes (approximately) | | Overrange indication | "1" is displayed | | Polarity | Automatic (no indication for positive polarity), Minus (-) sign for negative polarity. | | Measurement Rate | 2 times per second, nominal | | Low Battery Indication | " " is displayed if battery voltage drops below operating voltage | | Battery | One 9 volt (NEDA 1604) battery | | Fuses | mA, μA ranges; 0.2A/250V fast blow, A range; 20A/250V ceramic fast blow | | Operating Temperature | 41°F to 104°F (5°C to 40°C) | | Storage Temperature | -4°F to 140°F (-20°C to 60°C) | | Operating Humidity | Max 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F(40°C) | | Storage Humidity | <80% | | Operating Altitude | 7000ft. (2000meters) maximum. | | Weight | 0.753lb (342g) (includes holster). | | Size | 7.36" x 3.2" x 2.0" (187 x 81 x 50mm) (includes holster) | | Safety | For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (1995), EN61010-1 (1995) Overvoltage Category III, Pollution Degree 2. |
 |

Extech Instruments EX420 -Autoranging Digital MultiMeter
Features: Advanced measurements include Capacitance, Frequency, and Duty Cycle Relative function for establishing a base line references Type K thermometer built-in for surface or air temperature measurements Input fuse protection and mis-connection warnings Large 4000 count backlit LCD display with easy to read 1 inch digits Data Hold and Power Off Complete with CAT III test leads, multi-position tilt stand, hanging strap, holster with built-in test lead storage, bead wire temperature probe (-4 to 482°F/-20 to 250°C), and 9V battery Specifications: | DC Voltage | 0.1mV to 1000V | | Basic Accuracy | ±.3% (VDC) | | AC Voltage | 0.1mV to 750V | | DC/AC Current | 0.1µA to 20A | | Resistance | .01 §Ùto 40M §Ù; | | Capacitance | 0.01nF to 100µF | | Frequency | 0.001HZ to 10MHz | | Temperature (Type K) | -4 to 1382°F (-20 to 750°C) | | Duty Cycle | 0.1 to 99.9% | | Diode/Continuity | Yes | | Dimensions/Weight | 7.4x3.2x2" (187x81x50mm) | | Weight | 0.75lbs (342g) |
 |

Extech Instruments EX430 -True RMS autoranging MultiMeter with Capacitance, Frequency, and Duty Cycle functions
Features: Advanced measurements include Capacitance, Frequency, and Duty Cycle Relative function for establishing a base line reference True RMS AC measurements Type K thermometer built-in for surface or air temperature measurements Input fuse protection and mis-connection warnings with audible and visible signals Specifications: | Input Protection Limits | | V | DC or V AC 600V DC/AC, 200Vrms on 400mV range | | mA | AC/DC 500mA 250V fast acting fuse | | A | AC/DC 20A 250V fast acting fuse(30 seconds max every 15 minutes) | | Temperature | 60V DC/24V AC | | General | | Diode Test | Test current of 0.3mA maximum, open circuit voltage 1.5V DC typical | | Continuity Check | Audible signal will sound if the resistance is less than 150Ω (approx.), test current <0.7mA | | Temperature Sensor | Requires type K thermocouple | | Input Impedance | >7.5M Ω (VDC & VAC) | | AC Response | True rms | | ACV Bandwidth | 50Hz to 1kHz | | Display | 4000 count backlit liquid crystal | | Overrange indication | "OL" is displayed | | Auto Power Off | 15 minutes (approximately) | | Polarity | Automatic (no indication for positive); Minus (-) sign for negative | | Measurement Rate | 2 times per second, nominal | | Low Battery Indication | " " is displayed if battery voltage drops below operating voltage | | Battery | One 9 volt (NEDA 1604) battery | | Fuses | mA, μA ranges; 0.5A/250V fast blow A range; 20A/250V ceramic fast blow | | Operating Temperature | 41°F to 104°F (5°C to 40°C) | | Storage Temperature | -4°F to 140°F (-20°C to 60°C) | | Operating Humidity | Max 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F(40°C) | | Storage Humidity | <80% | | Operating Altitude | 7000ft. (2000meters) maximum. | | Weight | 0.753lb (342g) (includes holster). | | Size | 7.36" x 3.2" x 2.0" (187 x 81 x 50mm) (includes holster) | | Safety | For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (1995), EN61010-1 (1995) Overvoltage Category III, Pollution Degree 2. |
 |

Extech Instruments EX450 -Combination of MultiMeter and InfraRed Thermometer
Features: Non-contact InfraRed thermometer measures surface temperature of objects unsafe to contact or difficult to reach InfraRed features 8:1 distance to target ratio with 0.95 fixed emissivity Input fuse protection and mis-connection warnings with audible and visible signals Auto power off, Data Hold Specifications: | Input Protection Limits | | V | DC or V AC 600V DC/AC, 200Vrms on 200mV range | | mA | AC/DC 200mA 250V fast acting fuse | | A | AC/DC 20A 250V fast acting fuse(30 seconds max every 15 minutes) | | Resistance, Diode Test, Continuity | 250Vrms for 15sec max | | General | | Diode Test | Test current of 0.3mA maximum, open circuit voltage 1.5V DC typical | | Continuity Check | Audible signal will sound if the resistance is less than 150Ω (approx.), test current <0.7mA | | IR Spectral response | 6 to 16μm | | IR Emissivity | 0.95 fixed | | IR distance | ratio 8:1 | | Input Impedance | >7.5M Ω (VDC & VAC) | | AC Response | Average responding | | ACV Bandwidth | 50Hz to 1kHz | | Display | 2000 count backlit liquid crystal | | Overrange indication | "OL" is displayed | | Auto Power Off | 15 minutes (approximately) | | Polarity | Automatic (no indication for positive); Minus (-) sign for negative | | Measurement Rate | 2 times per second, nominal | | Low Battery Indication | " " is displayed if battery voltage drops below operating voltage | | Battery | One 9 volt (NEDA 1604) battery | | Fuses | mA, μA ranges; 0.2A/250V fast blow A range; 20A/250V ceramic fast blow | | Operating Temperature | 41°F to 104°F (5°C to 40°C) | | Storage Temperature | -4°F to 140°F (-20°C to 60°C) | | Operating Humidity | Max 80% up to 87°F (31º°C) decreasing linearly to 50% at 104°F(40°C) | | Storage Humidity | <80% | | Operating Altitude | 7000ft. (2000meters) maximum. | | Weight | 0.753lb (342g) (includes holster). | | Size | 7.36" x 3.2" x 2.0" (187 x 81 x 50mm) (includes holster) | | Safety | For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (1995), EN61010-1 (1995) Overvoltage Category III, Pollution Degree 2. |
 |

Extech Instruments EX470 -Combination of True RMS MultiMeter and InfraRed Thermometer, plus Type K Thermometer, Capacitance, Frequency, and Duty Cycle functions
Features: Non-contact InfraRed thermometer measures surface temperature of objects unsafe to contact or difficult to reach InfraRed features 8:1 distance to target ratio with 0.95 fixed emissivity Input fuse protection and mis-connection warnings with audible and visible signals Auto power off, Data Hold True RMS AC measurements Relative function Type K thermometer, Capacitance, Frequency, and Duty Cycle Complete with CAT III test leads, multi-position tilt stand, hanging strap, holster with test lead storage, bead wire temp probe, and 9V battery Specifications: | Input Protection Limits | | V DC or V AC | 600V DC/AC, 200Vrms on 400mV range | | mA AC/DC | 500mA 250V fast acting fuse | | A AC/DC | 20A 250V fast acting fuse(30 seconds max every 15 minutes) | | Frequency, Resistance, Capacitance, Duty Cycle, Diode Test, Continuity | 250Vrms for 15sec max | | Temperature | 60V DC/24V AC | | General | | Diode Test | Test current of 0.3mA maximum, open circuit voltage 1.5V DC typical | | Continuity Check | Audible signal will sound if the resistance is less than 150Ω (approx.), test current <0.7mA | | Temperature Sensor | Requires type K thermocouple | | IR Spectral response | 6 to 16μm | | IR Emissivity | 0.95 fixed | | IR distance ratio | 8:1 | | Input Impedance | >7.5M Ω (VDC & VAC) | | AC Response | True rms | | ACV Bandwidth | 50Hz to 1kHz | | Crest Factor | <3:1 at full scale & <6:1 at half scale | | Display | 4000 count backlit liquid crystal | | Overrange indication | "OL" is displayed | | Auto Power Off | 15 minutes (approximately) | | Polarity | Automatic (no indication for positive); Minus (-) sign for negative | | Measurement Rate | 2 times per second, nominal | | Low Battery Indication | " " is displayed if battery voltage drops below operating voltage | | Battery | One 9 volt (NEDA 1604) battery | | Fuses | mA, μA ranges; 0.5A/250V fast blow A range; 20A/250V ceramic fast blow | | Operating Temperature | 41°F to 104vF (5°C to 40°C) | | Storage Temperature | -4°F to 140°F (-20°C to 60°C) | | Operating Humidity | Max 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F(40°C) | | Storage Humidity | <80% | | Operating Altitude | 7000ft. (2000meters) maximum. | | Weight | 0.753lb (342g) (includes holster). | | Size | 7.36" x 3.2" x 2.0" (187 x 81 x 50mm) (includes holster) | | Safety | For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (1995), EN61010-1 (1995) Overvoltage CategoryIII, Pollution Degree 2. |
 |

Extech Instruments EX510 Heavy Duty Industrial MultiMeter 6000 count, Waterproof Rugged Design
Features: Double molded for waterproof (IP67) protection Rugged design — drop proof to 6 feet 6000 count 1000V input protection on all functions Dual sensitivity frequency functions Large backlit LCD with bargraph Duty Cycle function Diode open circuit voltage of 2.8V DC Auto power off with disable feature Min/Max/Relative/Data Hold CE and EN61010 CAT IV-600V, CAT III-1000V Complete with double molded test leads, magnetic hanging strap, carrying case, and one 9V battery Three year warranty Specifications: | EX510 | | Display counts | 6000 | | Basic Accuracy | 0.09% | | DC Voltage | 0.1mV to 1000V | | AC Voltage | 1mV to 1000V | | DC/AC Current | 0.1?A to 20A | | Resistance | 0.1? to 60M? | | Frequency (electrical) | 0.01 to 400Hz | | Frequency (electronic) | 0.001Hz to 40MHz | | Duty Cycle | 0.1 to 99.9% | | Diode | Yes | | Continuity | Yes | | Dimensions | 7.25x3.25x2.25" | | Weight | 12.3oz |
 |

Extech Instruments EX520 - Heavy Duty 6000 count, TRMS, Type K Thermometer, Capacitance, Waterproof Rugged Design
Features: Double molded for waterproof (IP67) protection Rugged design — drop proof to 6 feet True RMS 6000 count Type K Temperature Capacitance 1000V input protection on all functions Dual sensitivity frequency functions Large backlit LCD with bargraph Duty Cycle function Diode open circuit voltage of 2.8V DC Auto power off with disable feature Min/Max/Relative/Data Hold CE and EN61010 CAT IV-600V, CAT III-1000V Complete with double molded test leads, magnetic hanging strap, Type K bead wire temperature probe, carrying case, and one 9V battery Three year warranty Specifications: | Display counts | 6000 | | Basic Accuracy | 0.09% | | DC Voltage | 0.1mV to 1000V | | AC Voltage | 1mV to 1000V | | DC/AC Current | 0.1?A to 20A | | Resistance | 0.1? to 60M? | | Capacitance | 0.01nF to 1000?F | | Frequency (electrical) | 0.01 to 400Hz | | Frequency (electronic) | 0.001Hz to 40MHz | | Temperature (Type K) | -50 to 1382°F | | | (-45 to 750°C) | | Duty Cycle | 0.1 to 99.9% | | Diode | Yes | | Continuity | Yes | | Dimensions | 7.25x3.25x2.25" | | Weight | 12.3oz |
 |

Extech Instruments EX530 - Heavy Duty - TRMS Thermometer
Features: Double molded for waterproof (IP67) protection Rugged design - drop proof to 6 feet True RMS 40,000 count Type K Temperature Capacitance Peak Hold 4 to 20mA 1000V input protection on all functions Dual sensitivity frequency functions Large backlit LCD with bargraph Duty Cycle function Diode open circuit voltage of 2.8V DC Auto power off with disable feature Min/Max/Relative/Data Hold CE and EN61010 CAT IV-600V, CAT III-1000V Complete with double molded test leads, magnetic hanging strap, Type K bead wire temperature probe, carrying case, and one 9V battery Three year warranty
 |

Extech Instruments ML720 -True RMS multimeter datalog up to 43,000 data points
Features: 0.08% basic DCV accuracy ML720 — Store and View up to 43,000 data points 10 selectable datalogging sample rates from 0.05sec to 480 seconds True RMS Voltage and Current measurements Smart auto power off Hold and low resistance auto lead zero Specifications: | DC VOLTAGE | | RANGE | 50.00 mV | | Accuracy | 0.12% + 2d | | RANGE | 500.0 mV | | Accuracy | 0.06% + 2d | | RANGE | 5.000V, 50.00V, 500.0V, 1000V | | Accuracy | 0.08% + 2d | | NMRR | >60dB at 50/60Hz | | CMRR | >120dB at@ DC, 50/60Hz, Rs=1k Ω | | Input impedance | 10M Ω, 16pF nominal (44pF nominal for 50mV & 500mV ranges) | | AC VOLTAGE | | CMRR | &gr;60dB at DC to 60Hz, Rs=1k Ω | | Input Impedance | 10M Ω, 16pF nominal (44pF nominal for 50mV & 500mV ranges) | | TEMPERATURE | | RANGE | -50 °C TO 1000 °C | | Accuracy | 0.3% + 3d | | RANGE | -58 °F TO 1832 °F | | Accuracy | 0.3% + 6d | | RESISTANCE | | RANGE | 50.00 Ω | | Accuracy | 0.2% + 6d | | RANGE | 500.0 Ω | | Accuracy | 0.1% + 3d | | RANGE | 5.000k Ω, 50.00k Ω, 500.0k Ω | | Accuracy | 0.1% + 2d | | RANGE | 5.000M Ω | | Accuracy | 0.4% + 3d | | RANGE | 50.00M Ω | | Accuracy | 1.5% + 5d | | Open Circuit Voltage | < 1.3VDC (< 3VDC for 50 Ω & 500 Ω ranges) | | CAPACITANCE | | RANGE | 50.00nF, 500.0nF | | Accuracy | 0.8% + 3d | | RANGE | 5.000 μF | | Accuracy | 1.0% + 3d | | RANGE | 50.00 μF | | Accuracy | 2.0% + 3d | | RANGE | 500.0 μF | | Accuracy | 3.5% + 5d | | RANGE | 9999 μF | | Accuracy | 5.0% + 5d | | Digital Display | 5000-count LCD display, 5 per second nominal refresh rate | | Bar Graph Display | 52-segment bargraph; 60 per second nominal refresh rate | | Datalogging Capacity | 43000 points | | Datalogging Sample Rate | 0.05 (0.2 for o C/o F & §Ù, 0.4 for HZ and 1 for C), 1, 20, 40, 60, 120, 240 & 480 seconds | | Low Battery | Below approx. 7V | | Power Supply | 9V battery (NEDA1604, JIS006P or IEC6F22) | | AC Sensing | True RMS | | Auto Power Off | After 17 minutes of inactivity with no input signal |
 |

Extech Instruments MM560 - MultiMaster True RMS 50,000/500,000 count, high accuracy of 0.03%, wide bandwidth True RMS multimeter
Features: - 0.03% basic DCV accuracy
- 50,000 count display with 500,000 counts for DCV and Hz
- True RMS combination AC+DC function
- Highest resolution to 1μV, 0.01μA, 0.0001Hz, 0.01Ω
- 4 to 20mA, displayed as 0-100% for process current measurements
General Specifications:
| DC Loop | Current %4 to 20mA - 4mA = 0% (zero), 20mA = 100% (span), Resolution - 0.01%, Accuracy - ±25d | | Diode Test | Accuracy - 1%+1d, Current 0.8mA(typical), Open circuit - <3.5VDC | | Peak Capture (Instantaneous Peak Hold) | Accuracy - Specified accuracy ±100 digits for changes > 0.8ms in duration | | Audible Continuity | Measurement threshold - Between 20 Ω and 200 Ω, response time - <100 μs | | Accuracy Notes | Accuracy is ± (% reading + number of digits), or as otherwise specified, at 23 °C ±5 °C < 75% R.H. True RMS accuracies are specified from 5% to 100% of range or as otherwise specified. | | Maximum Crest Factor | <5:1 at full scale & <10:1 at half scale with frequency component within the specified frequency bandwidth for non-sinusoidal waveforms. | | Sensing | DC, AC True RMS, AC+DC True RMS | | Digital Display | 4-4/5 digits, 50000 count 5-4/5 digits, 500000 count for DCV 6 digits, 999999 count for Hz | | Bar Graph Display | 42-segment bargraph | | Polarity | Automatic | | Update rate | 5 /second for 50,000 count display (fast mode), 1.25/second for 500,000 count display (stable mode), 60 per second for bar graph display | | Low Battery | Below approx. 7V | | Operating Temperature | 41° to 104 °F (5° to 40°C) | | Storage Temperature | -4° to 140°F (-20 to 60°C) | | Relative Humidity | Max 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F(40°C), <80% storage | | Operating Altitude | Below 2000 meters | | Temp. Coefficient | Nominal 0.1x(specified accuracy)/°C at(0°C to 18°C or 28°C to 40°C), or otherwise specified | | Power Supply | 9V battery (NEDA1604, JIS006P or IEC6F22) | | Power Consumption | 5mA typical | | Auto Power Off | After 17 minutes of inactivity with no input signal. | | Power consumption during auto power off | 20 μA | | Safety | The MultiMaster Series meters are intended for indoor use and are protected, against the users, by double insulation per EN61010-1 and IEC61010-1 2nd Edition (2001) to CAT III 1000V & CAT IV 600V. The meter (all versions) also meets UL3111-1(1994) and CSA C22.2 No. 1010-1-92 to CAT III 1000V. | | Dimension | 7.32 x 3.43 x 1.4" with holster (186mm x 87mm x 35.5mm) | | Weight | 15.17 oz. with holster (430g) |
 |

Extech Instruments MM570 -50,000/500,000 count, high accuracy of 0.02%, wide bandwidth True RMS multimeter
Features: - 0.02% basic DCV accuracy
- dual input Type K Thermometer, higher True RMS ACV bandwidth (up to 100kHz) and 1000V input protection on all functions
- 50,000 count display with 500,000 counts for DCV and Hz
- True RMS combination AC+DC function
- Highest resolution to 1μV, 0.01μA, 0.0001Hz, 0.01Ω
- 4 to 20mA, displayed as 0-100% for process current measurements
Specifications:
| DC Loop | Current %4 to 20mA - 4mA = 0% (zero), 20mA = 100% (span), Resolution - 0.01%, Accuracy - ±25d | | Diode Test | Accuracy - 1%+1d, Current 0.8mA(typical), Open circuit - <3.5VDC | | Peak Capture (Instantaneous Peak Hold) | Accuracy - Specified accuracy ±100 digits for changes > 0.8ms in duration | | Audible Continuity | Measurement threshold - Between 20 Ω and 200 Ω, response time - <100 μs | | Accuracy Notes | Accuracy is ± (% reading + number of digits), or as otherwise specified, at 23 °C ±5 °C < 75% R.H. True RMS accuracies are specified from 5% to 100% of range or as otherwise specified. | | Maximum Crest Factor | <5:1 at full scale & <10:1 at half scale with frequency component within the specified frequency bandwidth for non-sinusoidal waveforms. | | Sensing | DC, AC True RMS, AC+DC True RMS | | Digital Display | 4-4/5 digits, 50000 count 5-4/5 digits, 500000 count for DCV 6 digits, 999999 count for Hz | | Bar Graph Display | 42-segment bargraph | | Polarity | Automatic | | Update rate | 5 /second for 50,000 count display (fast mode), 1.25/second for 500,000 count display (stable mode), 60 per second for bar graph display | | Low Battery | Below approx. 7V | | Operating Temperature | 41° to 104 °F (5° to 40°C) | | Storage Temperature | -4° to 140°F (-20 to 60°C) | | Relative Humidity | Max 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F(40°C), <80% storage | | Operating Altitude | Below 2000 meters | | Temp. Coefficient | Nominal 0.1x(specified accuracy)/°C at(0°C to 18°C or 28°C to 40°C), or otherwise specified | | Power Supply | 9V battery (NEDA1604, JIS006P or IEC6F22) | | Power Consumption | 5mA typical | | Auto Power Off | After 17 minutes of inactivity with no input signal. | | Power consumption during auto power off | 20 μA | | Safety | The MultiMaster Series meters are intended for indoor use and are protected, against the users, by double insulation per EN61010-1 and IEC61010-1 2nd Edition (2001) to CAT III 1000V & CAT IV 600V. The meter (all versions) also meets UL3111-1(1994) and CSA C22.2 No. 1010-1-92 to CAT III 1000V. | | Dimension | 7.32 x 3.43 x 1.4" with holster (186mm x 87mm x 35.5mm) | | Weight | 15.17 oz. with holster (430g) |
 |

Extech Instruments MN26T - MiniTec Multimeter
Features: - 4000 counts on large LCD with full function indication
- Measures AC/DC Voltage and Current,
- Resistance, Capacitance, Frequency and Temperature
- Temperature measurements to 1400°F (760°C)
- Duty Cycle, Continuity and Diode test
- Autoranging with manual range override
- Relative zero, Data Hold and Range Hold
- 10A fuse protection
- Overload protection and indication
- Auto power off saves battery life
- Includes protective rubber holster with stand, two 1.5V AAA batteries, and test leads
- CAT II-600V, CE & UL Listed
Specifications: | V DC, VAC | 600V DC/AC | | Ohms, Capacitance, Diode, Frequency, Continuity | 250V DC/AC | | mA DC/AC | 400mA DC/AC | | 10A DC/AC | 10A DC/AC (30sec. max) | | General | | Diode Test | Test current of 0.3mA maximum, open circuit voltage 1.5V DC typical | | Continuity Check | Audible signal will sound if the resistance is less than approximately 30 Ω, test current <0.7mA | | Temperature sensor | Requires type K thermocouple | | Input Impedance | 7.5M Ω (VDC and VAC) | | Display | 4000 count LCD | | Overrange indication | "OL" is displayed | | Polarity | Automatic (no indication for positive polarity); Minus (-) sign for negative polarity. | | Measurement Rate | 2 times per second, nominal | | Auto Power Off | Meter automatically shuts down after 15 minutes of inactivity | | Low Battery Indication | "BAT" is displayed if battery voltage drops below operating voltage | | Batteries | Requires two AAA batteries | | Fuses | mA, μA ranges, 0.5A/250V fast blow 10A range, 10A/250V fast blow | | Operating Temperature | 32°F to 122°F (0°C to 50°C) | | Storage Temperature | -4°F to 140°F (-20°C to 60°C) | | Relative Humidity | <70% operating, <80% storage | | Operating Altitude | 7000ft (2000 meters) maximum. | | Weight | 9.17 oz. (260g). | | Size | 4.78" x 2.38" x 1.57" (121.5mm x 60.6mm x 40mm) | | Safety | For indoor use and in accordance with Overvoltage Category II, Pollution Degree 2. Category II includes local level, appliance, portable equipment, etc., with transient overvoltages less than Overvoltage Category III. |
 |

Extech Instruments MP510 -High performance multimeter with RS-232 PC interface
Features: - 0.08% basic DCV accuracy
- Smart auto power off
- Hold and low resistance auto lead zero
- Optional SW800 PC software and cable sold separately
Specifications: | Digital Display | 5000-count LCD display, 5 per second nominal refresh rate | | Bar Graph Display | 52-segment bargraph; 60 per second nominal refresh rate | | Low Battery | Below approx. 7V | | Operating Temperature | 41° to 104°F (5° to 40°C) | | Storage Temperature | -4° to 140°F (-20 to 60°C) | | Relative Humidity | Max 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F(40°), <80% storage | | Altitude | Operating below 2000 meters | | Temp. Coefficient | Nominal 0.15 x specified accuracy per °C (between 0 and 18 °C or 28 to 50°C), or as otherwise specified | | Power Supply | 9V battery (NEDA1604, JIS006P or IEC6F22) | | AC Sensing | True RMS on MP520 and MP530 | | Auto Power Off | After 17 minutes of inactivity with no input signal | | Power Consumption | 2.7 mA typical | | Dimension | 7.32 x 3.43 x 1.4" with holster (186mm x 87mm x 35.5mm) | | Weight | 15.17 oz. with holster (430g) |
 |

Extech Instruments MP530 -High performance True RMS multimeter with RS-232 PC interface
Features: - 0.08% basic DCV accuracy
- True RMS
- Smart auto power off
- Hold and low resistance auto lead zero
- True RMS AC Voltage & Current, and Temperature functions plus Relative, Min, Max, Max-Min, Peak Hold and Zoom
- Optional SW800 PC software and cable sold separately
Specifications: | Digital Display | 5000-count LCD display, 5 per second nominal refresh rate | | Bar Graph Display | 52-segment bargraph; 60 per second nominal refresh rate | | Low Battery | Below approx. 7V | | Operating Temperature | 41° to 104°F (5° to 40°C) | | Storage Temperature | -4° to 140°F (-20 to 60°C) | | Relative Humidity | Max 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F(40°), <80% storage | | Altitude | Operating below 2000 meters | | Temp. Coefficient | Nominal 0.15 x specified accuracy per °C (between 0 and 18 °C or 28 to 50°C), or as otherwise specified | | Power Supply | 9V battery (NEDA1604, JIS006P or IEC6F22) | | AC Sensing | True RMS on MP530 and MP530 | | Auto Power Off | After 17 minutes of inactivity with no input signal | | Power Consumption | 2.7 mA typical | | Dimension | 7.32 x 3.43 x 1.4" with holster (186mm x 87mm x 35.5mm) | | Weight | 15.17 oz. with holster (430g) |
 |

Extech Instruments MT330 -True RMS Digital MultiMeter (0.1% basic DCV accuracy) with Temperature and oversized high contrast display indicates correct test probe connections, blown fuses, and to disconnect power for pas
Features: - Oversized high contrast 4000 count display
- Measures temperature
- True RMS responding
- Data Hold, Relative, and Auto Power off
- CAT II-1000V, CE & UL Listed
Specifications: | Duty Cycle | 0.1% to 99.9% | | Diode Test | Test voltage of 1.5V (max) | | Continuity Check | Audible tone if the resistance is less than 60 Ω | | Input Impedance | 10M Ω (VDC and VAC), 100M Ω in the 400mV range | | Display | 4000 count (3 3/4 digit) LCD, Model MT330 with back lighting | | Overrange indication | LCD displays "OL" | | Polarity | Auto positive polarity, Minus (-) sign for negative polarity | | Low Battery Indication | Battery symbol indicates low battery condition. | | Power Supply | One 9V battery (NEDA 1604) | | Fuses μA, mA ranges | 500mA/250V ceramic, 20A range - 20A/250V ceramic | | Operating Temperature | 32°F to 104°F (0°C to 40°C) | | Storage Temperature | -4°F to 140°F (-20°C to 60°C) | | Accuracy Temperature | 64°F to 82°F (18°C to 28°C) | | Relative Humidity | < 80% RH operating, (<70% RH storage) | | Dimensions / Weight | 3.5x7x1.3" (88x178x33mm) / 0.7lb (315g) |
 |

Extech Instruments MV110 -MultiView Series Digital MultiMeter Manual Ranging
Features: - 2000 count (3-1/2 digits)
- Basic DCV accuracy of 0.5%
- Battery check for 9V and 1.5V batteries
- 50Hz square wave output
Specifications: | Display | 1999 count 3 1/2 digit, adjustable angle | | Sample Rate | Approximately 2 - 3 per second | | Input warning Alarm | sounds with test leads in the A or 10A socket and the wrong function is selected. | | Fuse Protection | 2A (A socket), 0.2A (mA socket), 10A or 20A range not fused | | Power Supply | 9V battery (NEDA 1604 or equivalent) | | Range selection | Manual | | Over-range Indication | "1" | | Auto Off | Unit switches off after 15 minutes of inactivity | | Low Battery Indication | battery symbol | | Operating Temperature/Humidity | 32°F to 104°F (0°C to 40°C) / < 75% RH | | Storage Temperature | 14°F to 122°F (-10°C to 50°C) | | Dimension / Weight | 7.3 x 3.5 x 1.3" (185x89x32mm) LxWxH / approx. 9.7 oz. (300 grams) |
 |
Extech Instruments TTK32 - True RMS Professional Electrical/HVAC
True RMS Professional Electrical/HVAC Clamp-on Kit TK32 Kit is contains the necessary test tools for reparing, installing and troubleshooting electrical and HVAC equipment. All the equipment comes packaged in a lightweight case that's handy and easily portable out in the field. True RMS Professional Current Clamp Meter Kit TK32 Kit is contains the necessary test tools for reparing, installing and troubleshooting electrical and HVAC equipment. All the equipment comes packaged in a lightweight case that's handy and easily portable out in the field.
 |

Extech Instruments TK430 - Electrical Test Kit
Description: Assembled to accomodate all the electrical testing needs for installation and repair of electrical systems, HVAC equipment and large appliances. Includes: EX430 True RMS Autoranging Digital Multimeter, MA200 400A Clamp Meter, 40130 Non-Contact Voltage Detector, set of CAT III-1000V test leads, Type K thermocouple bead probe, and Type K to Banana Input Adaptor.
 |
Extech Instruments TK430-IR Industrial Troubleshooting Kit
Description: Provide all the electrical testing needs for installation and repair of electrical systems, HVAC equipment and large appliances. Includes: EX430 True RMS multimeter includes 11 functions (AC/DC Voltage and Current, Resistance, Capacitance, Frequency, Temperature, Duty Cycle, Diode, and Continuity 42510 Mini IR Thermometer offers non-contact temperature measruements on surfaces difficult or unsafe to reach (-58 to 1000°F/-50 to 538°C) MA200 400A AC Clamp Meter includes 6 functions (AC Current, AC/DC Voltage, Resistance, Diode, and Continuity) 40130 Non-contact AC Voltage Detector measuresvoltages from 100V to 600V Supplied in an attractive storage case that provides protection and organization for the meters whenever they are needed Dimensions: 9.5x6.8x2.8” (241x173x71mm) 1 Year Warranty
 |

Extech Instruments TK505 - Professional MultiMeter Kit
Professional MultiMeter Kit Advanced kit contains the most commonly used testing tools for Electrical/HVAC and plant maintenance Kit contains an EX505 True RMS Autoranging MultiMeter, EX730 800A True RMS AC/DC Clamp Meter, DV20 Non-Contact AC Voltage Detector, and a 480172 AC Line Splitter Supplied in an attractive storage case that provides protection and organization for the meters and accessories whenever they are needed
 |

Extech Instruments TK730 - Electrical Test Kit
Professional Clamp Meter Test Kit True RMS Professional Clamp with InfraRed Thermometer for non-contact Temperature measurements Includes: EX730: 800A True RMS AC/DC Clamp Meter (0.1A Resolution, ±3% AC accuracy) 480172: AC line splitter enables use of a clamp meter to measure AC Current on a 2-wire or 3-wire power cord to 15A DV20: Non-contact AC Voltage Detector (detects Voltage from 100 to 600V) 42510: Mini InfraRed Thermometer (-58 to 1000°F/-50 to 538°C) Set of test leads and Type K Thermocouple UL approved on EX730, DV20, and 480172 Dimensions: 9.5x6.8x2.8 (241x173x71mm
 |
|
|
|
|