Extech Instruments 392050 - Penetration Stem
Features: - Temperature range: -58 to 302°F (-50 to 150°C)
- Basic Accuracy of 2°F or 1°C
- 0.1° resolution to 199.9; 1° over 200°
- ON/OFF switch saves battery life
- Auto power off after 1hr of non use
Specifications: | Display | 3-1/2 digit LCD with °C/°F degree indicator | | Measurement ranges | -58 to 302°F (-50 to 150°C) | | Auto Off | After one hour of operation | | Resolution | 0.1°C/F from -19.9 to 199.9°F (-20 to 150°C) | | Accuracy | <2°F (1°C) from -14 to 212°F (-50 to 100°C) | | Sensor length | 5.1" (130mm) | | Sensor material | Stainless steel | | Operating temperature | -14 to 122°F (0 to 40°C) | | Battery power | 1.5V LR44 cell (5000 hour approx. life) |
 |

Extech Instruments 392052 - Flat Surface Stem
Features: High temperature range: -58 to 572°F (-50 to 300°C) Basic Accuracy of 2°F or 1°C 0.1° resolution to 199.9; 1° over 200° ON/OFF switch saves battery life Auto power off after 1hr of non use Specifications: | Display | 2000 count liquid crystal display | | Units | °C/°F selectable | | Measurement range | -58 to 572°F (-50 to 300°C) | | Resolution | 0.1°to 199.9°, 1° > 199.9° | | Accuracy | ±1.8°F (1°C) from -22 to 452°F (-30 to 250°C), ±4°F, (2°C) outside this range | | Sensor length | 5" (130mm) | | Sensor tip diameter | 0.57" (14.5mm) | | Sensor material | Stainless steel | | Auto Off | After one hour of operation | | Operating temperature for display | 14 to 122°F (-10 to 50°C) (dial display) | | Battery one | 1.5V LR44 cell or equivalent (A76/G13) cell |
 |

Extech Instruments 392065 - T Bar Stem Thermometer
Features: - 4.9" (124mm) stainless steel probe
- 0.35" (9mm) LCD display
- ON/OFF switch saves battery life
- Temperature: -58 to 302°F (-50 to 150°C); ±2°F/1°C accuracy, 0.1°/1° resolution
- Weight: 0.6oz (17g), 0.8oz (23g) with plastic sheath
- Complete with plastic protective sheath with pocket clip and 1.5V button battery
Specifications: | Ranges | -58 to 302°F (-50 to 150°C) | | Display | 0.35" (9mm) LCD display | | Dimensions | 4.9" (124mm) stainless steel probe | | Weight | 0.6oz (17g), 0.8oz (23g) with plastic sheath | | Accessories | plastic protective sheath with pocket clip and 1.5V button battery | | Accuracy | ±2°F/1°C | | Resolution | 0.1°/1° |
 |

Extech Instruments 392085 - Pocket Thermometer
Features: - Audible alarm alerts user when pre-set max or min temperature is reached or exceeded
- Display Hold function freezes temperature reading on display
- Ranges: -58 to 302°F (-50 to 150°C)
- 0.1° resolution from -19.9 to +199.9° 1° over 200°
- Accurate to ±1.8°F from -58 to 212°F (±1°C from -50 to 100°C)
- Durable 2-1/2" stainless steel probe with 20" cable
- Complete with wallet style case, stainless steel probe, and 1.5V button battery
Specifications: | Measurement Range | -50°C to +150°C or -58°F to +302°F | | Resolution | 0.1° (-19.9° to +199.9°), 1°greater than 199.9° | | Accuracy | ±1.0°C (-50°C to +100°C), ±1.8°C greater than +100°C, ±1.8°F (-58°F to 212°F), ±3.6°F greater then 212°F | | Battery | one 1.5V "A76" size (G13 or equivalent) | | Sensor | 2.5" Stainless steel sensing probe | | Operating temperature | -10°C to +40°C, -50°F to +104°F | | Demensions/weight | 4.8x3x8" (122x76x20mm), 3.4oz. (96g) |
 |
Extech Instruments 39240 - Waterproof Thermometer
Features: - 2.75" (70mm) Stainless steel stem
- °C/°F switchable ranges of -40 to 392°F (-40 to 200°C)
- MAX/MIN recall of high and low temperatures
- Hold and Auto Off features
- Digital display with 0.1° resolution
- Dimensions: 5.9 x 0.8 x 0.7" (150 x 20 x 18mm);
- Weight: 0.7oz (20g)
- Complete with one LR44 button battery and protective cover
Specifications: | Ranges | °C/°F switchable -40 to 392°F (-40 to 200°C) | | MAX/MIN | recall of high and low temperatures | | Features | Hold and Auto Off | | Display | Digital with 0.1° resolution | | Dimensions | 5.9 x 0.8 x 0.7" (150 x 20 x 18mm); | | Weight | 0.7oz (20g) | | Accessories | LR44 button, battery and protective cover | | Accuracy | ±2°F/1°C | | Resolution | 0.1°/1° |
 |
Extech Instruments 39272 - Pocket Fold up Thermometer with Adjustable Probe
Features: - Wide °C/°F switchable temperature range -58 to 572°F (-50 to 300°C)
- Fold up probe 4.5" (114mm) adjusts from 0° to 180° for best measurement and viewing angle
- Large LCD display with 0.1 degree resolution
- Auto power off after 1 hour or when probe is placed in stored position
- Data Hold and Min/Max recordings
- Fast response time - one second under normal conditions
- Complete with wrist strap and one AAA battery
Specifications: | Display | 3-1/2 digit LCD with °C/°F degree indicator | | Measurement ranges | -58 to 572°F (-50 to 300°C) | | Resolution | 0.1°C/F | | Accuracy | ±1.8°F (1°C) from -22 to 482°F (-30 to 150°C) | | Sensor length | 4.5" (117mm) | | Sensor material | Stainless steel | | Operating temperature | -14 to 122°F (-10 to 40°C) | | Battery power | (1)AAA Battery |
 |

Extech Instruments 401012 - Indoor/Outdoor Temperature Alarm
Features: - Large 1.5" LCD displays indoor/outdoor temperature simultaneously from -58 to 158°F, resolution 0.1°F and accuracy to ±1.8°F
- Single Point Alarm (external sensor): set to alarm when temperature is above HI SET or below LO SET point
- Dual Point Alarm (external sensor): set to alarm when temperature is either outside of or within two setpoints
- Audible alarm and Red/Green LED indication for 5 seconds every minute when setpoint(s) is reached
 |

Extech Instruments 401014 - Big Digit Indoor/Outdoor Thermometer
Features: - Large LCD displays 1" (25mm) digits for indoor/outdoor temperature
- Indoor Range: 14 to 140°F (-10 to 60°C)
- Outdoor Range: -58 to 158°F (-50 to 70°C) ±1.8°F /1°C accuracy; 0.1°F/°C resolution
Specifications: | Indoor temperature | 14 to 140°F (-10 to 60°C) | | Outdoor temperature | -58 to 158°F (-50 to 70°C) | | Resolution | 0.1° for F (0.1° for C) | | Accuracy | ±1.8°F (±1°C) from 32 to 122°F (0 to 50°C), ±3.6°F from -58 to 32°F and 122 to 158°F (±2°C from -50 to 0°C and +50 to +70°C) | | Power supply | One (1) 'AAA' 1.5 V battery | | Sensor cable length | Approx. 9' (3m) | | Dimensions | 3.9x4.25x0.75" (99x108x19mm) |
 |

Extech Instruments 401021 - Foot Candle Light MultiMeter Adaptor
Features: - Three ranges (5% accuracy):
- 0 to 5,000Fc
- 1mV/Fc or Lux output
- CE approved .
Specifications: | Accuracy | ± (5% + 1mV) | | Sensor | Exclusive photo diode & color correction filter spectrum designed to meet C. I. E. | | Operating Temperature/humidity | 32°F to 122°F (0C to 50°C) / <90% RH | | Power Supply | 006P DC 9V battery | | Power Consumption | Approx. 6 mA DC | | Low battery indication | Status LED on Front panel of Adaptor | | Dimensions / Weight | 3.9x1.9x1" (100x50x25mm) / 0.33 lbs. (150g) |
 |

Extech Instruments 401025 - Foot Candle/Lux Meter
Features: - Accurately displays light level in terms of Fc or Lux over three ranges
- Select fast (1 second) or slow (2 seconds) response time
- Analog output of 1mV per count for capturing readings to a recorder
Specifications: | Display | 0.5" (13 mm) LCD (Liquid Crystal Display). | | Measurement | Lux, Ft-candle (Fc). | | Ranges | Lux: 0 to 50,000 Lux, 3 ranges. Foot-candle: 0-5,000 Fc, 3 ranges. | | Sensor | Exclusive photo diode & color correction filter, spectrum designed to meet C. I. E. | | Zero Adj. | Manual adjustment. | | Sampling Time | Approx. 0.4 sec. | | Response Time | Fast & Slow selector. | | Over input indication | Indication of "1 " | | Analog Output | 0.1 mV/1 digit, max. output 200mV. | | Operating Temperature | 32°F to 122°F, 0°C to 50°C | | Operating Humidity | Less than 80% RH. | | Power Supply | 006P DC 9V battery | | Power Current | Approx. 2 mA DC | | Weight | 220 g / 0.52 LB | | Dimension Main instrument | 6.4x2.8x1.2 inch (163x70x30mm). | | Sensor Probe | 3.2x2.2x0.5 inch (85x55x12 mm). | | Optional Accessories | Vinyl pouch carrying case, 409996 |
 |

Extech Instruments 403125 - Light Probe Meter
Features: - Backlit display to view in dimly lit areas
- Remote light sensor on 59" (1.5m) cable conveniently mounts on top of meter for one hand operation and safe storage
- Data hold and Peak hold
- Optional analog output cable 403999 allows mV analog output for recording measurements
 |

Extech Instruments 407026 - Heavy Duty Light Meter with PC Interface
Features: % displays differential from reference point "ZERO" Re-Calibration Enhance accuracy by selecting lighting type Tungsten/Daylight, Fluorescent, Sodium, Mercury) Data Hold, Min/Max/Avg readings Built-in RS-232 PC serial interfaceSpecifications: | Circuit | Custom one-chip LSI microprocessor circuit | | Display | 3-1/2 digit (2000 count) LCD display with contrast adjustment | | Measurement ranges | LUX: 0 to 50,000 LUX (3 range); Fc: 0 to 5000 Fc (3 range); Relative mode: 0 to 1999% | | Data Hold | Freezes displayed reading | | Lighting Types | Sodium, Daylight/Tungsten, Fluorescent and Mercury | | Sensor Structure | Cosine/color corrected photo-diode meets C.I.E. | | Memory Store/Recall | Records/Recalls Max/Min/Avg readings | | Sample rate | 0.4 seconds (approx.) per reading | | Zero Adjust | Push-button procedure | | Auto Power Off | After approx. 10 minutes | | Data Output | RS-232 PC serial interface (optional software/cable PN 407001) | | Operating conditions | 32 °F to 122 °F (0 °C to 50 °C); <80% RH | | Power Supply | 9V battery | | Power consumption | Approx. 5 mA DC. (approx. 200 hr battery life) | | Weight | 0.71 lbs. (320 g) | | Dimensions Instrument | 7.1 x 2.8 x1.3" (180 x 72 x 32 mm) | | Sensor | 3.3 x 2.2 x 0.7" (85 x 55 x 17.5 mm) |
 |

Extech Instruments 407113 - Heavy Duty CFM Metal Vane Anemometer
Features: - Display Air Flow (CFM) or Air Velocity plus Temperature
- Air Flow displayed in 3 modes: - Instantaneous value - Up to 20 point average or - 2/3 flow value
- Record and Recall MIN, MAX
- Data Hold plus Auto power off
- Built-in RS-232 PC Interface
Specifications: | Display | Dual Display Multi-function 10,000-count (0 to 9999) LCD | | Measurements | Air Velocity - m/s, km/h, ft/min, knots, mph; Air Flow - CMM (m 3 /min) and CFM (ft 3 /min); Temperature - °C and °F | | Data Hold | Freezes displayed reading | | Sampling rate | One (1) reading per second | | Sensors | Air velocity/flow sensor: Metal angled vane arms with low-friction ball bearing. | | Temp. Sensor | Precision thermistor | | MIN/MAX | Records/Recalls lowest and highest readings | | Auto Power OFF | Automatic shut off after 15 minutes | | PC Interface | RS-232 Serial Communications (16-bit data stream) | | Over range indication | 1___ appears on the LCD | | Low battery indication | LBT appears on the LCD | | Power supply | 9V Battery (consumption 8.3mA approx.) | | Operating conditions Meter | 32 to 122°F (0 to 50°C); 80% RH max. | | Sensor | 32 to 175°F (0 to 80°C) | | Dimensions / Weight Main instrument | 7.1 x 2.8 x1.3" (180 x 72 x 32mm) | | Sensor head | 2.8" (72mm) diameter | | Weight | 0.84 lbs. (381g) for meter and sensor | | m/s (meters per second) | | Range | 0.50 - 40.00 m/s | | Resolution | 0.01 m/s | | Accuracy | ± (2% + 0.2m/s) | | km/h (kilometers per hour) | | Range | 1.8 - 144.0 km/h | | Resolution | 0.1 km/h | | Accuracy | ± (2% + 0.2km/h) | | ft/min (feet per minute) | | Range | 100 - 7880 ft/min | | Resolution | 1 ft/min | | Accuracy | ± (2% + 20ft/min) | | mph (miles per hour) | | Range | 1.1 - 89.4 mph | | Resolution | 0.1 mph | | Accuracy | ± (2% + 0.2m/h) | | knots (nautical miles per hour ) | | Range | 1.0 to 78.1 knots | | Resolution | 0.1 knots | | Accuracy | ± (2% + 0.2knots) | | CMM (cubic meters per minute) | | Range | 0-999,900 m³/min | | Resolution | 0.001 to 100 | | Accuracy | 0 to 9,999m² | | CFM (cubic feet per minute) | | Range | 0-999,900 ft³/min | | Resolution | 0.001 to 100 | | Accuracy | 0 to 9,999ft² | | Air Temperature | | Range | 32 to 175°F (0 to 80°C) | | Resolution | 0.1°F/C | | Accuracy | 1.5°F (0.8°C) |
 |

Extech Instruments 407119 - Heavy Duty CFM Hot Wire Anemometer
Features: Air velocity measurements as low as 40ft/min Telescoping probe is ideal for use in ducts and ventilating systems; extends up to 4ft (1.22m) long 20 point averaging for airflow Record and recall MIN/MAX readings Data Hold plus Auto power off Built-in RS-232 PC Interface Specifications: | Display | Dual function 4-digit LCD | | Measurement units | Air Velocity - m/s, km/h, ft/min, knots, mph; Air Flow - CMM (m³/min) and CFM (ft³/min); Temp - °C and °F | | Data hold | Freezes displayed reading | | Sampling rate | 1 second approx. | | Sensors Air velocity sensor | Glass bead thermistor | | Temperature sensor | Thermistor | | MAX/MIN | Memory Record and view Maximum and Minimum readings | | Automatic Power off | Auto shut off after 15 minutes | | Data Output | RS-232 PC serial interface with 16-bit data stream output | | Operating Temperature Meter | 32 to 122°F (0 to 50°C) | | Sensor | 32 to 176°F (0 to 80°C) | | Operating Humidity Max. | 80% Relative Humidity | | Power Supply | Six (6) ‘AAA' 1.5V batteries | | Power Current | Approx. DC 30mA | | Weight | (meter only) 0.78 lbs. (355g) | | Dimensions Main instrument | 7.1 x 2.8 x1.3" (180 x 72 x 33mm) | | Telescoping Sensor | 0.5" (12.7mm) diameter head; 37" (.94m) maximum antenna length with 78" (2m) cable |
 |
Extech Instruments 407123 - Heavy Duty Hot Wire
Features: - Telescoping probe is ideal for measuring in HVAC ducts and other small vents; extends up to 4ft (1.22m) long
- Super large 1.4" (36mm) dual LCD display
- Min/Max, Data Hold
Specifications: | Circuit configuration | Custom one-chip LSI microprocessor circuit | | Display | 3-1/2 digit (2000 count) dual LCD display | | Measurements | m/s (meters per second), km/h (kilometers per hour), ft/min | | (feet/per minute), knots (nautical miles per hour), MPH (miles per hour), °C, °F | | Data hold | Freezes reading on display | | Sensor | Structure Air velocity sensor: Glass bead thermistor | | Temperature sensor | Precision thermistor | | Min/Max Recording | Record and Recall Maximum (MAX) and Minimum readings | | PC Interface | RS 232 PC serial interface jack for use with Model 407001 software and interface cable kit | | Operating Temperature | 32 to 122°F (0 to 50 °C) | | Operating Humidity | Max. 80% RH | | Power Supply | Six 1.5V ‘AAA' batteries | | Power Consumption | Approx. 30 mADC | | Weight | 0.78 lb (355 g) including batteries & probe | | Dimensions Main instrument | 7.1 x 2.8 x 1.3" (180 x 72 x 32 mm) | | Sensor | 0.5" (12mm) diameter | | Telescope | 3.9' (1.22m) maximum length with cable. | | m/s | | Range | 0.2 to 20.0 m/s | | Resolution | 0.1 m/s | | Accuracy | ± (3% + 1d) of reading or ±(1% + 1d) Full Scale | | (whichever is greater) | | km/h | | Range | 0.7 to 72.0 km/h | | Resolution | 0.1 km/h | | Accuracy | ± (3% + 1d) of reading or ±(1% + 1d) Full Scale | | (whichever is greater) | | ft/min | | Range | 40 to 3940 ft/min | | Resolution | 1 ft/min | | Accuracy | ± (3% + 1d) of reading or ±(1% + 1d) Full Scale | | (whichever is greater) | | MPH | | Range | 0.5 to 45.0 MPH | | Resolution | 0.1 MPH | | Accuracy | ± (3% + 1d) of reading or ±(1% + 1d) Full Scale | | (whichever is greater) | | knots | | Range | 1.0 to 31.0 knots | | Resolution | 0.1 knots | | Accuracy | ± (3% + 1d) of reading or ±(1% + 1d) Full Scale | | (whichever is greater) | | Temperature | | Range | 32 to 122°F (0 to 50°C) | | Resolution | 0.1°F and °C | | Accuracy | 1.5°F (0.8°C) |
 |