AEMC 2121.10 - Phase Rotation Meter
3-Phase Rotation Meter Description: The Phase Rotation Meter Catalog 2121.10 is a compact and rugged meter designed to identify phase rotation on 3-Phase systems and identify live and open/de-energized phases. Ideal for installing rotating machinery or motors, and for checking generator output Features: - Phase rotation indicators
- Color-coded leads (red, black, blue) and alligator clips (black)
- Simple operation
- Line supplied - no battery
- 600V CAT III rated and CE Mark
Applications: - Verify proper phase wiring
- Detect open or de-energized phases
- Determine correct wiring for proper rotation on motors, pumps, etc.
List Price: $69.00
Add to Cart |

 Click to zoom |
AEMC 2121.11 - Motor / Transformer Testers
Phase & Motor Rotation Meter Catalog 2121.11 Description: The Phase Rotation Meter Catalog 2121.11 is a compact and rugged meter designed to identify phase rotation on 3-Phase systems and identify live and open/de-energized phases. Ideal for installing rotating machinery or motors, and for checking generator output. The Catalog 2121.11 is also an ideal tool for measuring the proper rotation of motors, conveyors, pumps and other electrical devices interconnected on the power line system before installation where direction of rotation is dependent on proper phase hook-up Features: - Phase and motor rotation indicators
- Color-coded leads (red, black, blue) and alligator clips (black)
- Simple operation
- 600V CAT III rated and CE Mark
|
Applications: - Verify proper phase wiring
- Detect open or de-energized phases
- Determine correct wiring for proper rotation on motors, pumps, etc.
List Price: $99.00
Add to Cart |

 Click to zoom |
AEMC 2136.50 - Motor / Transformer Testers
Digital Transformer Ratiometer Catalog 2136.50 (110/220V) Replacement for Cat #2111.80 & 2116.21 Description: The Catalog DTR 8510 is a portable digital transformer ratiometer designed for on-site testing of power, potential and current transformers. When connected to a non-energized transformer, the Catalog 2136.50 accurately measures primary to secondary turns ratio, while simultaneously displaying polarity and excitation current. The DTR® is fully automatic and uses an ANSI/IEEE compliant test method. No user calibration, range selection, hand cranking or tedious balancing is required. At each measurement, the DTR® automatically self-calibrates and checks for open windings/connections/circuit breakers, short circuits (excess excitation current), incorrect test lead placement, and reverse polarity. Measurements are displayed quickly and accurately. Features: - Ratio Testing: PT/VT from 0.8000:1 to 8000:1 and CT from 0.8000 to 1000.0 (Auto-Ranging)
- Tests performed by exciting the primary and reading the secondary; provides safer conditions for the operator on step-down transformers
- Continuity test indicates open or loose (high resistance) terminal connections
- DC test mode eliminates errors due to magnetic build up
- Stores up to 10 primary/secondary nameplate voltages to use in comparing test results
- Displays ratio, test current, winding polarity, and deviation from nameplate voltage or ratio
- Stores up to 10,000 test results
- DataView® software included which allows configuring the instrument, downloading stored measurements and printing of test results in a report format
- Display warns of incorrect lead connection, reverse polarity, open and short circuits
Applications: - Power transformers
- Potential transformers
- Current transformers
List Price: $2,995.00
Add to Cart |

 Click to zoom |
AEMC 6608 - Phase Rotation Meter
3-Phase Rotation Meter Description: The Phase Rotation Meter Model 6608 is a compact and rugged meter designed to identify phase rotation on 3-Phase systems and identify live and open/de-energized phases. Ideal for installing rotating machinery or motors, and for checking generator output Features: - Phase rotation indicators
- Color-coded leads (red, black, blue) and alligator clips (black)
- Simple operation
- Line supplied - no battery
- 600V CAT III rated and CE Mark
Applications: - Verify proper phase wiring
- Detect open or de-energized phases
- Determine correct wiring for proper rotation on motors, pumps, etc.
List Price: $69.00
Add to Cart |

 Click to zoom |
AEMC 6609 - Motor / Transformer Testers
Phase & Motor Rotation Meter Model 6609 Description: The Phase Rotation Meter Model 6609 is a compact and rugged meter designed to identify phase rotation on 3-Phase systems and identify live and open/de-energized phases. Ideal for installing rotating machinery or motors, and for checking generator output. The Model 6609 is also an ideal tool for measuring the proper rotation of motors, conveyors, pumps and other electrical devices interconnected on the power line system before installation where direction of rotation is dependent on proper phase hook-up Features: - Phase and motor rotation indicators
- Color-coded leads (red, black, blue) and alligator clips (black)
- Simple operation
- 600V CAT III rated and CE Mark
|
Applications: - Verify proper phase wiring
- Detect open or de-energized phases
- Determine correct wiring for proper rotation on motors, pumps, etc.
List Price: $99.00
Add to Cart |

 Click to zoom |
AEMC DTR 8510 - Motor / Transformer Testers
Digital Transformer Ratiometer Model DTR 8510 (110/220V) Replacement for Cat #2111.80 & 2116.21 Description: The Model DTR 8510 is a portable digital transformer ratiometer designed for on-site testing of power, potential and current transformers. When connected to a non-energized transformer, the Model DTR 8510 accurately measures primary to secondary turns ratio, while simultaneously displaying polarity and excitation current. The DTR® is fully automatic and uses an ANSI/IEEE compliant test method. No user calibration, range selection, hand cranking or tedious balancing is required. At each measurement, the DTR® automatically self-calibrates and checks for open windings/connections/circuit breakers, short circuits (excess excitation current), incorrect test lead placement, and reverse polarity. Measurements are displayed quickly and accurately. Features: - Ratio Testing: PT/VT from 0.8000:1 to 8000:1 and CT from 0.8000 to 1000.0 (Auto-Ranging)
- Tests performed by exciting the primary and reading the secondary; provides safer conditions for the operator on step-down transformers
- Continuity test indicates open or loose (high resistance) terminal connections
- DC test mode eliminates errors due to magnetic build up
- Stores up to 10 primary/secondary nameplate voltages to use in comparing test results
- Displays ratio, test current, winding polarity, and deviation from nameplate voltage or ratio
- Stores up to 10,000 test results
- DataView® software included which allows configuring the instrument, downloading stored measurements and printing of test results in a report format
- Display warns of incorrect lead connection, reverse polarity, open and short circuits
Applications: - Power transformers
- Potential transformers
- Current transformers
List Price: $2,995.00